SY/T 5533-2002 DS series electromagnetic eddy current brake for oil drilling rigs
time:
2024-08-06 19:53:00
- SY/T 5533-2002
- in force
Standard ID:
SY/T 5533-2002
Standard Name:
DS series electromagnetic eddy current brake for oil drilling rigs
Chinese Name:
石油钻机用DS系列电磁涡流刹车
Standard category:
Oil and gas industry standards (SY)
-
Date of Release:
1992-11-03 -
Date of Implementation:
1993-04-01
Standard ICS number:
Petroleum and related technologies>>Equipment for the oil and gas industry>>75.180.10 Exploration and drilling equipmentChina Standard Classification Number:
Petroleum>>Petroleum Exploration, Development, Gathering and Transportation Equipment>>E92 Petroleum Drilling Equipment and Instruments
alternative situation:
SY/T 5533-1992

Skip to download
Summary:
SY/T 5533-2002 DS series electromagnetic eddy current brake for oil drilling rigsSY/T5533-2002 Standard download decompression password: www.bzxz.net

Some standard content:
ICS 75.180.16
Registration No.: 10437-2002
Petroleum and natural gas industry standard of the People's Republic of China SY/T 5533-2002
Replaces SY/T 5533-92
Oil drill rig of DS series eddy current brakeOil drill rig of DS series eddy current brake2002-05-28 Issued
State Economic and Trade Commission
2002-0801 Implementation
SY/T5533-2002
This standard is revised on the basis of SY/T5533--92 "IS series eddy current brake". The purpose of the revision is to maintain consistency with the newly released GB/T17744-1999 "Drilling Equipment Specification" and SY/T5609-1999 "Oil Drilling Rig Type and Basic Parameters", and enrich the new structural type. Technical performance indicators and other contents to meet the needs of the market. Compared with SY/T5533-92, the main changes of this standard are: 1. The nominal drilling depth (referred to as nominal drilling depth) range is calibrated with 114mm drill rod, and the nominal drilling depth range cancels the original 20 levels, and adds 30 and 120 levels.
1. Added relevant content of air-cooled electromagnetic eddy current brake. Improved the insulation level standard of electromagnetic eddy current brake excitation line diagram. From the date of entry into force, this standard will replace SY/T5533--92 at the same time. This standard was proposed and managed by the National Technical Committee for the Promotion of Petroleum Drilling Equipment and Tools. The drafting unit of this standard: Lanzhou Petrochemical Machinery General Factory, the main drafters of this standard: Qi Kangsheng, Gao Wei, He Yan, Luo Xianjun. The previous versions of the standards replaced by this standard are as follows:--SY/F5533-92
1 Range
DS series electromagnetic eddy current brake for oil drilling rigsSY/T 5533-2002
This standard specifies the terms and definitions, models, basic parameters, technical requirements, inspection methods, inspection rules and markings, packaging, transportation and storage of DS series electromagnetic eddy current brakes (hereinafter referred to as eddy current brakes). This standard applies to the design, manufacture and inspection of DS series eddy current brakes for oil drilling rigs. 2 Normative references
The clauses in the following documents become the clauses of this standard through reference in this standard. For all dated references, all subsequent amendments (excluding errata) or revisions are not applicable to this standard. However, the parties who reach an agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. For all undated references, the latest versions are applicable to this standard. GB3836.2 Electrical equipment for explosive gas atmospheres Part 2: Flameproof type GB/T8423-1997 Vocabulary of petroleum drilling equipment and special pipes GB/T13306 Signs
SY5305 General technical conditions for welded parts for petroleum drilling machinery products (confirmed in 1998)
SY5308 General technical conditions for paint for petroleum drilling machinery products [confirmed in 1998]
SY5309 General technical conditions for packaging for petroleum drilling machinery products (confirmed in 1998)
JB794 Heat resistance classification of insulating materials for motors, electrical appliances and transformers 3 Terms and definitions
GB/T84231997 and the following terms and definitions apply to this standard. 3.1
Main structure of eddy current car
Refers to the eddy current brake component consisting of rotor, stator and shell. 3.2
Eddy current brake residual torquehrake rcsidual torque refers to the torque required to reversely rotate the rotor at rated speed when the eddy current brake stops inputting excitation current. 3.3
Air gap
Refers to the gap between the metal surface of the inner surface of the rotor and the outer surface of the stator. The air gap value refers to its radial distance. 3.4
Rated speed
Rated speed
DS30, LS40, LDS50, DS70, DS90, DS120 eddy current brake rotor is 50r/m1n speed. 4 Models and basic parameters
4.1 Model
SY /T 5533-2002
The expression method of eddy current brake model is as follows. DS
Eddy current brake level: Using 114mm drill rod, the upper limit of the nominal drilling depth range is measured in units of 100m
Cooling form: No mark means water-cooled type, plus F means air-cooled type Filter flow brake code
Example: The water-cooled eddy current brake model with a level of 40 is DS40, and the air-cooled eddy current brake model with a level of 50 is DSF50. 4.2 Basic parameters of eddy current brakes
The basic parameters of eddy current brakes are shown in Table 1.
Basic parameters
Rated braking torque, kN·m
Applicable drilling depth, m
Maximum no-load speed, t/mun
Maximum excitation power, kw
Cooling water flow, L/mun
Cooling air volume, m/h
Maximum mountain water (wind) overflow,
Maximum water inlet (wind; temperature, r
Braking torque at rated speed
DS (F) 30
DS (F) 40
"The upper limit of the nominal drilling depth range when using a drill rod with a diameter of 114 mm. Applicable to water-cooled type.Www.bzxZ.net
1Applicable to air-cooled type.
TS (F) 50
DS (F) 70
30-70, the left side is the cooling water temperature, the right side is the cooling air temperature; 90-120, only water-cooled type. 4.3 Eddy current brake body maximum dimensions and shaft end dimensions Eddy current brake body maximum dimensions and shaft end dimensions see Figure 1 and Table 2. Table 2
Dimensions』
LS (F)40
LS (F) 30
LS (F) 50
LIS (F)70
Dimensions
5 Technical requirements
DS (F) 30
Table 2 (continued)
DS (F)40
TS (F) 50
Shaft spring enlargement
DS (F) 70
Rotor. External filling
SY/T 5533-—2002
Air gap
5.1 Eddy current brakes shall comply with the provisions of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. SY/T 5533—2002
5.2 The maximum air gap values of various specifications of eddy current brakes shall comply with the provisions of Table 3. Table 3
TS (F) 30 DS (F) 40
Maximum air gap value, mm
DS (F) 50
DS (F) 70
5.3 Eddy current brake electrical equipment, including junction boxes and sealed joints, should be explosion-proof. Its explosion-proof requirements should comply with the provisions of GB3836.2,
5.4 The insulation level of the excitation coil should not be lower than the H level in JB794. 5.5 The resistance of the excitation coil to ground should not be lower than 20MQ. 5.6 The quality of the weld should comply with the provisions of SY5305. 5.7 The quality of the paint should comply with the provisions of SY5308. 5.8 The eddy current brake should run smoothly and without abnormal noise. 5.9 When the eddy current brake is in operation, the temperature rise of the bearing should not exceed 40°C, 5.10 Leakage is not allowed at the seals of the eddy current brake. 5.11 The maximum residual torque of the eddy current brake is DS3), DS40 It should not be greater than 1% of the rated braking torque, DS50, DS70, DS90), DS120 should not be greater than 0.8% of the rated braking torque: 5.12 Complete set scope:
a) Eddy current car main body;
b) One eddy current brake bracket;
One power box (including rectifier, transformer); One driller switch:
e) DC power cable and control cable.
6 Inspection methods and inspection rules
6.1 Factory inspection
Eddy current cars should be inspected one by one by the quality inspection department of the manufacturer, and can only be shipped after passing the inspection. 6.1.1 The insulation level of the excitation coil should be inspected in accordance with the provisions of 5.4. 6.1.2 Use a 500V megohmmeter to check the resistance of the excitation coil to ground in accordance with the provisions of 5.5. 6.1.3 Turn the rotor shaft and press 5.2. Check the air gap value according to the provisions of 2. Every time it rotates 120, use a feeler gauge to measure the gap value through the six observation holes on both sides of the eddy current brake. Rotate three times continuously, and measure three gap values for each observation hole according to the above provisions. Among the 18 air gaps, more than 14 should meet the requirements to be qualified: the air gap value is equal to the gap value plus the coating thickness of the stator outer cylindrical surface plus the coating thickness of the rotor inner cylindrical surface). 6.1.4 Check the operation according to the provisions of 5.8, at a speed of not less than 150r/min, without cooling water (wind), without inputting excitation current, and run idly for more than 20min.
At a speed of not less than 250r/min, pass cooling water (wind), do not input excitation current, and run idly for more than 1h. The amount of cooling water for water-cooled type is based on a small amount of water spraying out after the screw plugs are opened at the upper observation holes on both sides of the eddy current brake. Check the temperature rise of the bearing and the seals at all locations according to the provisions of 5.9 and 5.10. 1) The coating thickness shall be based on the production inspection record or on-site disassembly inspection. 4
6.1.5 Inspect the weld quality according to the provisions of 5.6. 6.1.6 Inspect the coating quality according to the provisions of 5.7. 6.1.7 Inspect the electrical equipment of eddy current brake according to the provisions of 5.3. 6.2 Type inspection
6.2.1 Type inspection shall be carried out in any of the following situations: a) When the new product or old product is transferred to the factory for trial production and identification; b) After formal production, if there are major changes in structure, materials, and processes, which may affect product performance; c) When the quality and technical supervision agency proposes a requirement for type inspection. 6.2.2 Type inspection shall be carried out after all factory inspection items are qualified. SY/T 55332002
6.2.3 According to the maximum no-load speed specified in Table 1, water (wind) no-load operation shall be carried out, and the time shall be no less than J: 20min. In the bearing temperature rise, it shall comply with the provisions of 5.9.
6.2.4 New products should be tested for external characteristics on the test bench designated by the quality supervision agency. Under different load conditions (excitation power from zero to the maximum allowable value), change the speed of the eddy current brake main shaft, measure the braking torque at different speeds under different excitation powers, and draw a characteristic curve. At the rated speed, the braking torque generated by the maximum excitation power should comply with the provisions in Table 1.
6.2.5 After the load test, the excitation current is cut off and the brake braking effect is terminated. At the rated speed, the reverse rotation brake is turned. At this time, the inner cavity still passes cooling water (air) according to the specified displacement, and the residual torque on the rotor shaft is measured. Its value should comply with the provisions of 5.11: 6.2.6 During the type test, the cooling water (air) flow rate, the inlet and outlet water temperature of the water cooling system, and the inlet and outlet temperature of the air cooling system are measured, which should comply with the provisions in Table 1:
7 Marking, packaging, transportation, storage
7.1 Marking and packaging
7.1.1 The brake sign should be firmly fixed in a conspicuous position. The size of the label shall comply with the provisions of GB/T13306. The content of the label includes: ε) Product model:
b) Product name;
c) Applicable and deep;
d) Rated braking torque;
Maximum no-load speed;
) Cooling water (wind) flow;
g) Maximum excitation power;
h) Coil insulation level;
) Overall dimensions:
) Quality;
k) Factory date:
1) Factory number:
m) Manufacturer name;
n) Trademark.
7.1.2 The packaging of eddy current brakes shall comply with the provisions of SY5309. 7.1.3 Before packaging, protective measures shall be taken for the threads and shaft extensions (or toothed clutches on the shaft) for water inlet and outlet. 7.1.4 The main body of the eddy current brake is generally naked. 7.1.5 The power box, driller switch, power transformer, DC power cable and control cable should be packed. 7.1.6 The documents sent randomly should be packed with rainproof and moisture-proof packaging, including the following documents: a) Product certificate;
SY/T5533-2002
Product manual:
Drawings or atlas sent randomly;
d) Delivery list and packing list.
7.2 Transportation
During transportation, the parts such as water pipes, respirators and junction boxes should be prevented from being damaged by knocking, squeezing and squeezing. 7.3
Eddy current brakes should be stored in a dry, ventilated warehouse without corrosive media. Sun exposure and rain are strictly prohibited.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Registration No.: 10437-2002
Petroleum and natural gas industry standard of the People's Republic of China SY/T 5533-2002
Replaces SY/T 5533-92
Oil drill rig of DS series eddy current brakeOil drill rig of DS series eddy current brake2002-05-28 Issued
State Economic and Trade Commission
2002-0801 Implementation
SY/T5533-2002
This standard is revised on the basis of SY/T5533--92 "IS series eddy current brake". The purpose of the revision is to maintain consistency with the newly released GB/T17744-1999 "Drilling Equipment Specification" and SY/T5609-1999 "Oil Drilling Rig Type and Basic Parameters", and enrich the new structural type. Technical performance indicators and other contents to meet the needs of the market. Compared with SY/T5533-92, the main changes of this standard are: 1. The nominal drilling depth (referred to as nominal drilling depth) range is calibrated with 114mm drill rod, and the nominal drilling depth range cancels the original 20 levels, and adds 30 and 120 levels.
1. Added relevant content of air-cooled electromagnetic eddy current brake. Improved the insulation level standard of electromagnetic eddy current brake excitation line diagram. From the date of entry into force, this standard will replace SY/T5533--92 at the same time. This standard was proposed and managed by the National Technical Committee for the Promotion of Petroleum Drilling Equipment and Tools. The drafting unit of this standard: Lanzhou Petrochemical Machinery General Factory, the main drafters of this standard: Qi Kangsheng, Gao Wei, He Yan, Luo Xianjun. The previous versions of the standards replaced by this standard are as follows:--SY/F5533-92
1 Range
DS series electromagnetic eddy current brake for oil drilling rigsSY/T 5533-2002
This standard specifies the terms and definitions, models, basic parameters, technical requirements, inspection methods, inspection rules and markings, packaging, transportation and storage of DS series electromagnetic eddy current brakes (hereinafter referred to as eddy current brakes). This standard applies to the design, manufacture and inspection of DS series eddy current brakes for oil drilling rigs. 2 Normative references
The clauses in the following documents become the clauses of this standard through reference in this standard. For all dated references, all subsequent amendments (excluding errata) or revisions are not applicable to this standard. However, the parties who reach an agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. For all undated references, the latest versions are applicable to this standard. GB3836.2 Electrical equipment for explosive gas atmospheres Part 2: Flameproof type GB/T8423-1997 Vocabulary of petroleum drilling equipment and special pipes GB/T13306 Signs
SY5305 General technical conditions for welded parts for petroleum drilling machinery products (confirmed in 1998)
SY5308 General technical conditions for paint for petroleum drilling machinery products [confirmed in 1998]
SY5309 General technical conditions for packaging for petroleum drilling machinery products (confirmed in 1998)
JB794 Heat resistance classification of insulating materials for motors, electrical appliances and transformers 3 Terms and definitions
GB/T84231997 and the following terms and definitions apply to this standard. 3.1
Main structure of eddy current car
Refers to the eddy current brake component consisting of rotor, stator and shell. 3.2
Eddy current brake residual torquehrake rcsidual torque refers to the torque required to reversely rotate the rotor at rated speed when the eddy current brake stops inputting excitation current. 3.3
Air gap
Refers to the gap between the metal surface of the inner surface of the rotor and the outer surface of the stator. The air gap value refers to its radial distance. 3.4
Rated speed
Rated speed
DS30, LS40, LDS50, DS70, DS90, DS120 eddy current brake rotor is 50r/m1n speed. 4 Models and basic parameters
4.1 Model
SY /T 5533-2002
The expression method of eddy current brake model is as follows. DS
Eddy current brake level: Using 114mm drill rod, the upper limit of the nominal drilling depth range is measured in units of 100m
Cooling form: No mark means water-cooled type, plus F means air-cooled type Filter flow brake code
Example: The water-cooled eddy current brake model with a level of 40 is DS40, and the air-cooled eddy current brake model with a level of 50 is DSF50. 4.2 Basic parameters of eddy current brakes
The basic parameters of eddy current brakes are shown in Table 1.
Basic parameters
Rated braking torque, kN·m
Applicable drilling depth, m
Maximum no-load speed, t/mun
Maximum excitation power, kw
Cooling water flow, L/mun
Cooling air volume, m/h
Maximum mountain water (wind) overflow,
Maximum water inlet (wind; temperature, r
Braking torque at rated speed
DS (F) 30
DS (F) 40
"The upper limit of the nominal drilling depth range when using a drill rod with a diameter of 114 mm. Applicable to water-cooled type.Www.bzxZ.net
1Applicable to air-cooled type.
TS (F) 50
DS (F) 70
30-70, the left side is the cooling water temperature, the right side is the cooling air temperature; 90-120, only water-cooled type. 4.3 Eddy current brake body maximum dimensions and shaft end dimensions Eddy current brake body maximum dimensions and shaft end dimensions see Figure 1 and Table 2. Table 2
Dimensions』
LS (F)40
LS (F) 30
LS (F) 50
LIS (F)70
Dimensions
5 Technical requirements
DS (F) 30
Table 2 (continued)
DS (F)40
TS (F) 50
Shaft spring enlargement
DS (F) 70
Rotor. External filling
SY/T 5533-—2002
Air gap
5.1 Eddy current brakes shall comply with the provisions of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. SY/T 5533—2002
5.2 The maximum air gap values of various specifications of eddy current brakes shall comply with the provisions of Table 3. Table 3
TS (F) 30 DS (F) 40
Maximum air gap value, mm
DS (F) 50
DS (F) 70
5.3 Eddy current brake electrical equipment, including junction boxes and sealed joints, should be explosion-proof. Its explosion-proof requirements should comply with the provisions of GB3836.2,
5.4 The insulation level of the excitation coil should not be lower than the H level in JB794. 5.5 The resistance of the excitation coil to ground should not be lower than 20MQ. 5.6 The quality of the weld should comply with the provisions of SY5305. 5.7 The quality of the paint should comply with the provisions of SY5308. 5.8 The eddy current brake should run smoothly and without abnormal noise. 5.9 When the eddy current brake is in operation, the temperature rise of the bearing should not exceed 40°C, 5.10 Leakage is not allowed at the seals of the eddy current brake. 5.11 The maximum residual torque of the eddy current brake is DS3), DS40 It should not be greater than 1% of the rated braking torque, DS50, DS70, DS90), DS120 should not be greater than 0.8% of the rated braking torque: 5.12 Complete set scope:
a) Eddy current car main body;
b) One eddy current brake bracket;
One power box (including rectifier, transformer); One driller switch:
e) DC power cable and control cable.
6 Inspection methods and inspection rules
6.1 Factory inspection
Eddy current cars should be inspected one by one by the quality inspection department of the manufacturer, and can only be shipped after passing the inspection. 6.1.1 The insulation level of the excitation coil should be inspected in accordance with the provisions of 5.4. 6.1.2 Use a 500V megohmmeter to check the resistance of the excitation coil to ground in accordance with the provisions of 5.5. 6.1.3 Turn the rotor shaft and press 5.2. Check the air gap value according to the provisions of 2. Every time it rotates 120, use a feeler gauge to measure the gap value through the six observation holes on both sides of the eddy current brake. Rotate three times continuously, and measure three gap values for each observation hole according to the above provisions. Among the 18 air gaps, more than 14 should meet the requirements to be qualified: the air gap value is equal to the gap value plus the coating thickness of the stator outer cylindrical surface plus the coating thickness of the rotor inner cylindrical surface). 6.1.4 Check the operation according to the provisions of 5.8, at a speed of not less than 150r/min, without cooling water (wind), without inputting excitation current, and run idly for more than 20min.
At a speed of not less than 250r/min, pass cooling water (wind), do not input excitation current, and run idly for more than 1h. The amount of cooling water for water-cooled type is based on a small amount of water spraying out after the screw plugs are opened at the upper observation holes on both sides of the eddy current brake. Check the temperature rise of the bearing and the seals at all locations according to the provisions of 5.9 and 5.10. 1) The coating thickness shall be based on the production inspection record or on-site disassembly inspection. 4
6.1.5 Inspect the weld quality according to the provisions of 5.6. 6.1.6 Inspect the coating quality according to the provisions of 5.7. 6.1.7 Inspect the electrical equipment of eddy current brake according to the provisions of 5.3. 6.2 Type inspection
6.2.1 Type inspection shall be carried out in any of the following situations: a) When the new product or old product is transferred to the factory for trial production and identification; b) After formal production, if there are major changes in structure, materials, and processes, which may affect product performance; c) When the quality and technical supervision agency proposes a requirement for type inspection. 6.2.2 Type inspection shall be carried out after all factory inspection items are qualified. SY/T 55332002
6.2.3 According to the maximum no-load speed specified in Table 1, water (wind) no-load operation shall be carried out, and the time shall be no less than J: 20min. In the bearing temperature rise, it shall comply with the provisions of 5.9.
6.2.4 New products should be tested for external characteristics on the test bench designated by the quality supervision agency. Under different load conditions (excitation power from zero to the maximum allowable value), change the speed of the eddy current brake main shaft, measure the braking torque at different speeds under different excitation powers, and draw a characteristic curve. At the rated speed, the braking torque generated by the maximum excitation power should comply with the provisions in Table 1.
6.2.5 After the load test, the excitation current is cut off and the brake braking effect is terminated. At the rated speed, the reverse rotation brake is turned. At this time, the inner cavity still passes cooling water (air) according to the specified displacement, and the residual torque on the rotor shaft is measured. Its value should comply with the provisions of 5.11: 6.2.6 During the type test, the cooling water (air) flow rate, the inlet and outlet water temperature of the water cooling system, and the inlet and outlet temperature of the air cooling system are measured, which should comply with the provisions in Table 1:
7 Marking, packaging, transportation, storage
7.1 Marking and packaging
7.1.1 The brake sign should be firmly fixed in a conspicuous position. The size of the label shall comply with the provisions of GB/T13306. The content of the label includes: ε) Product model:
b) Product name;
c) Applicable and deep;
d) Rated braking torque;
Maximum no-load speed;
) Cooling water (wind) flow;
g) Maximum excitation power;
h) Coil insulation level;
) Overall dimensions:
) Quality;
k) Factory date:
1) Factory number:
m) Manufacturer name;
n) Trademark.
7.1.2 The packaging of eddy current brakes shall comply with the provisions of SY5309. 7.1.3 Before packaging, protective measures shall be taken for the threads and shaft extensions (or toothed clutches on the shaft) for water inlet and outlet. 7.1.4 The main body of the eddy current brake is generally naked. 7.1.5 The power box, driller switch, power transformer, DC power cable and control cable should be packed. 7.1.6 The documents sent randomly should be packed with rainproof and moisture-proof packaging, including the following documents: a) Product certificate;
SY/T5533-2002
Product manual:
Drawings or atlas sent randomly;
d) Delivery list and packing list.
7.2 Transportation
During transportation, the parts such as water pipes, respirators and junction boxes should be prevented from being damaged by knocking, squeezing and squeezing. 7.3
Eddy current brakes should be stored in a dry, ventilated warehouse without corrosive media. Sun exposure and rain are strictly prohibited.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 10330.2-2004 High-speed electric spark small hole machining machine Part 2: Parameters
- GB/T 4893.3-1985 Determination of dry heat resistance of furniture surface paint film
- GB 12971.3-1991 Contact wire for electric traction Part 3: Steel and aluminum composite contact wire
- HG/T 3638-1999 Document duplication film dimensions
- JB/T 10019-1999 Gear pitch measuring instrument
- QB/T 1751-1993 石砚
- GB/T 14556-1993 Interface requirements for marine navigation radar
- SY 4032.1-1993 Petroleum Construction Project Quality Inspection and Assessment Standard Communication Engineering (Long-distance Communication Open Line Engineering)
- GB/T 34313-2017 Grading and evaluation standard of tour guides
- JB/T 7948.9-1999 Chemical analysis methods for melting fluxes - Flame photometric method for determination of sodium oxide and potassium oxide content
- GB/T 3789.21-1991 Test method for electrical performance of transmitting tubes Test method for reference point of static characteristics
- GB/T 14885-1994 Classification and codes for fixed assets
- GB/T 15463-1995 静电安全术语
- JB/T 8791-1998 Spring-loaded internal diameter dial indicator
- GB 50235-1997 Code for construction and acceptance of industrial metal pipeline projects
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]