GB 4121-1983 Test method for thermochromicity of quartz glass
time:
2024-08-10 14:59:32
- GB 4121-1983
- in force
Standard ID:
GB 4121-1983
Standard Name:
Test method for thermochromicity of quartz glass
Chinese Name:
石英玻璃热变色性试验方法
Standard category:
National Standard (GB)
-
Date of Release:
1983-12-30 -
Date of Implementation:
1984-11-01
Standard ICS number:
Glass and ceramic industry >> 81.040 GlassChina Standard Classification Number:
Building Materials>>Ceramics, Glass>>Q35 Quartz Glass
alternative situation:
Replaces JC 189-1981
Release date:
1983-12-30Review date:
2004-10-14Drafter:
Liu Jun'e, Zhu MingdiDrafting Organization:
Building Materials Research InstituteFocal point Organization:
China Building Materials Industry AssociationProposing Organization:
State Bureau of Building Materials IndustryPublishing Department:
National Bureau of StandardsCompetent Authority:
China Building Materials Industry Association

Skip to download
Summary:
This standard applies to the test of thermochromic properties of transparent quartz glass tubes and other products. GB 4121-1983 Test method for thermochromic properties of quartz glass GB4121-1983 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Test method for stability tothermal darkening of silica glass
The test method for stability tothermal darkening of silica glass This standard is applicable to the inspection of the thermal darkening performance of transparent quartz glass tubes and other products. Test principle
UDG 669.192: 666
.11.01
GB 4121—83
After heat treatment, the light transmittance of transparent quartz glass changes. The change in transmittance at a wavelength of 290nm is used as the degree of color change performance. 2 Preparation of test samples
2.1 Quantity: three.
2.2 The shape and size shall comply with the provisions of the following table: mm
Pipe or product
Pipe with a diameter less than 40
Pipe with a diameter greater than 40
Test specimen shape and size
Tube length 30~40, cut into two parts axially
Tube length 30~40, cut into test specimens with a chord width of 20 30×15×s (plate thickness) test specimens
2.3 The appearance quality of the test specimen shall comply with the corresponding JC177-81 "DTSi transparent quartz glass tube" or JC224--81 "DTS2 transparent quartz glass tube" provisions.
3 Test equipment and materials
3.1 High-temperature electric furnace, working temperature 1000±20℃. 3.2 One electric oven.
3.3 One UV spectrophotometer, with a transmittance measurement accuracy of ±1%. 3.4 A gas-refined quartz glass sample box with a lid, with a specification size of 100mm×80mm. 3.5 One chrome-plated crucible tongs and one bamboo clip.
3.6 One 125mm vernier caliper, with an accuracy of 0.02mm. 3.7 Chemically pure anhydrous ethanol.
3.8 Absorbent gauze or absorbent cotton.
3.9 Glass beaker.
4 Test preparation
4.1 Sample preparation:
National Bureau of Standards 1983-12-30 Issued
1984-11-01 Implementation
GB4121-83
4.1.1 Place the sample in a beaker with anhydrous ethanol and soak for 15-20 minutes, take it out, and wipe it with absorbent gauze. 4.1.2 Clean the sample box and lid for the test in the same way. 4.1.3 Place the sample in the sample box with a clamp, place the sample box and lid with the sample in an oven, dry (do not cover the lid during drying) and set aside.
4.2 Heating
Raise the furnace temperature to 1000±20℃.
4.3 Adjust the UV spectrophotometer.
5 Test steps
5.1 Adjust the wavelength dial of the spectrophotometer to 290nm and calibrate 100% transmittance. 5.2 Place the treated sample in the sample holder of the UV spectrophotometer and record the transmittance curve from 200 to 400nm. 5.3 Place the sample with measured transmittance in the sample box, cover it with a lid, and place it in the high-temperature electric furnace prepared in 4.2 and keep it warm for 2 hours. 5.4 Take out the sample box with the sample from the furnace, cool it in the air, and measure the transmittance of the sample in 5.2. 6 Result calculation
6.1 The color change performance of quartz glass after heat treatment is expressed as the transmittance change value △T, %/mm, of the sample with unit thickness at a wavelength of 290nm, and is calculated as follows:
T, -T2
Where: T, transmittance of the sample at 290nm before heat treatment, %T2——transmittance of the sample at 290nm after heat treatment, %, d
-sample thickness, mm.
6.2 Take the average value of the transmittance change values of the three samples as the transmittance change value of this batch of samples. 7 Test record and test report
7.1 Record the sample number and the unit of delivery on the recording paper of the spectral transmittance curve. 7.2 Test report: Fill in the test report in the following format and content. Quartz glass transmittance measurement test record
Sample submission unit
Sample name
Test date
Sample number
Sample thickness
Sample submission date
Sample number
Tester,
Test results
Sample submission unit
Sample name
Test date
Sample number
Additional notes:
GB4121—83
Quartz glass heat treatment discoloration performance test reportSample submission date
Sample number
Transmittance change value AT at a wavelength of 290nm, %/mmTester
Testing unit:www.bzxz.net
Responsible person
This standard is proposed by the State Bureau of Building Materials Industry and is under the jurisdiction and interpretation of the Building Materials Science Research Institute. This standard was drafted by the Building Materials Science Research Institute. The main drafters of this standard are Liu Jun'e and Zhu Mingdi.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Test method for stability tothermal darkening of silica glass
The test method for stability tothermal darkening of silica glass This standard is applicable to the inspection of the thermal darkening performance of transparent quartz glass tubes and other products. Test principle
UDG 669.192: 666
.11.01
GB 4121—83
After heat treatment, the light transmittance of transparent quartz glass changes. The change in transmittance at a wavelength of 290nm is used as the degree of color change performance. 2 Preparation of test samples
2.1 Quantity: three.
2.2 The shape and size shall comply with the provisions of the following table: mm
Pipe or product
Pipe with a diameter less than 40
Pipe with a diameter greater than 40
Test specimen shape and size
Tube length 30~40, cut into two parts axially
Tube length 30~40, cut into test specimens with a chord width of 20 30×15×s (plate thickness) test specimens
2.3 The appearance quality of the test specimen shall comply with the corresponding JC177-81 "DTSi transparent quartz glass tube" or JC224--81 "DTS2 transparent quartz glass tube" provisions.
3 Test equipment and materials
3.1 High-temperature electric furnace, working temperature 1000±20℃. 3.2 One electric oven.
3.3 One UV spectrophotometer, with a transmittance measurement accuracy of ±1%. 3.4 A gas-refined quartz glass sample box with a lid, with a specification size of 100mm×80mm. 3.5 One chrome-plated crucible tongs and one bamboo clip.
3.6 One 125mm vernier caliper, with an accuracy of 0.02mm. 3.7 Chemically pure anhydrous ethanol.
3.8 Absorbent gauze or absorbent cotton.
3.9 Glass beaker.
4 Test preparation
4.1 Sample preparation:
National Bureau of Standards 1983-12-30 Issued
1984-11-01 Implementation
GB4121-83
4.1.1 Place the sample in a beaker with anhydrous ethanol and soak for 15-20 minutes, take it out, and wipe it with absorbent gauze. 4.1.2 Clean the sample box and lid for the test in the same way. 4.1.3 Place the sample in the sample box with a clamp, place the sample box and lid with the sample in an oven, dry (do not cover the lid during drying) and set aside.
4.2 Heating
Raise the furnace temperature to 1000±20℃.
4.3 Adjust the UV spectrophotometer.
5 Test steps
5.1 Adjust the wavelength dial of the spectrophotometer to 290nm and calibrate 100% transmittance. 5.2 Place the treated sample in the sample holder of the UV spectrophotometer and record the transmittance curve from 200 to 400nm. 5.3 Place the sample with measured transmittance in the sample box, cover it with a lid, and place it in the high-temperature electric furnace prepared in 4.2 and keep it warm for 2 hours. 5.4 Take out the sample box with the sample from the furnace, cool it in the air, and measure the transmittance of the sample in 5.2. 6 Result calculation
6.1 The color change performance of quartz glass after heat treatment is expressed as the transmittance change value △T, %/mm, of the sample with unit thickness at a wavelength of 290nm, and is calculated as follows:
T, -T2
Where: T, transmittance of the sample at 290nm before heat treatment, %T2——transmittance of the sample at 290nm after heat treatment, %, d
-sample thickness, mm.
6.2 Take the average value of the transmittance change values of the three samples as the transmittance change value of this batch of samples. 7 Test record and test report
7.1 Record the sample number and the unit of delivery on the recording paper of the spectral transmittance curve. 7.2 Test report: Fill in the test report in the following format and content. Quartz glass transmittance measurement test record
Sample submission unit
Sample name
Test date
Sample number
Sample thickness
Sample submission date
Sample number
Tester,
Test results
Sample submission unit
Sample name
Test date
Sample number
Additional notes:
GB4121—83
Quartz glass heat treatment discoloration performance test reportSample submission date
Sample number
Transmittance change value AT at a wavelength of 290nm, %/mmTester
Testing unit:www.bzxz.net
Responsible person
This standard is proposed by the State Bureau of Building Materials Industry and is under the jurisdiction and interpretation of the Building Materials Science Research Institute. This standard was drafted by the Building Materials Science Research Institute. The main drafters of this standard are Liu Jun'e and Zhu Mingdi.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 19341-2003 Fruit bag paper
- SJ 20685-1998 General specification for airborne communication anti-interference radio receiving channel module
- SY 0055-1993 Specification for measurement of long-distance oil and gas pipelines
- JB/T 9271-1999 Pressure gauges for welding, cutting and similar processes
- QB/T 3770.2-1999 Sampling and testing methods for compressed hops and pelleted hops
- JB/T 3576-1999 General technical requirements for rust prevention of rock drilling machinery and pneumatic tools
- SJ 1283-1977 Test methods for corrosion of metallic coatings and chemically treated layers
- GB 13104-1991 Hygienic standard for white sugar
- HG 21546.6-1993 Rotary drum inlet and outlet box sealing device (JC type) and technical requirements
- SY 5670-1993 Petroleum and liquid petroleum products railway tank car transfer measurement procedures
- GB/T 14665-1998 Mechanical Engineering CAD Drawing Rules
- GB/T 3253.1-2001 Chemical analysis method for antimony - Determination of arsenic content
- GB/T 13379-1992 Principles of visual ergonomics-The lighting of indoor work systems
- HG/T 20703.9-2000 Key points for material professionals to participate in on-site inspection
- QB/T 2694-2005 Thermal lottery paper
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com