
GB 3776.2-1983 Determination of hydrogen ion concentration of pesticide emulsifiers
time:
2024-08-10 19:43:28
- GB 3776.2-1983
- Abolished
Standard ID:
GB 3776.2-1983
Standard Name:
Determination of hydrogen ion concentration of pesticide emulsifiers
Chinese Name:
农药乳化剂氢离子浓度测定方法
Standard category:
National Standard (GB)
-
Date of Release:
1983-06-15 -
Date of Implementation:
1984-06-01 -
Date of Expiration:
2005-10-14
Standard ICS number:
Agriculture>>65.100 Pesticides and other agricultural chemical productsChina Standard Classification Number:
Chemical Industry>>Fertilizers, Pesticides>>G23 Basic Standards and General Methods for Pesticides
Review date:
2004-10-14Drafter:
Zhang Junzhi, Tao DemingDrafting Organization:
Nanjing Zhongshan Chemical PlantFocal point Organization:
Technology of Shenyang Research Institute of Chemical Industry, Ministry of Chemical IndustryProposing Organization:
Ministry of Chemical Industry of the People's Republic of ChinaPublishing Department:
National Bureau of StandardsCompetent Authority:
China Petroleum and Chemical Industry Association

Skip to download
Summary:
This method is applicable to the determination of hydrogen ion concentration of pesticide emulsifiers. GB 3776.2-1983 Determination of hydrogen ion concentration of pesticide emulsifiers GB3776.2-1983 Standard download decompression password: www.bzxz.net

Some standard content:
1 Scope of application
National Standard of the People's Republic of China
Method of hydrogen ion concentrationdetermination for pesticide emulsifiers This method is applicable to the determination of hydrogen ion concentration of pesticide emulsifiers. 2 Reagents and solutions
2.1 Distilled water: pH value 6.5~7.0.
2.2 Potassium dihydrogen phosphate (GB1274-77): analytical grade. 2.3 Disodium hydrogen phosphate (GB1263--77): analytical grade. UDC 66.063.61
GB 3776.2-83
(confirmed in 1989)
2.4 Preparation of standard buffer solution: Weigh 3.04 g potassium dihydrogen phosphate and 3.55 g disodium hydrogen phosphate that have been dried to constant weight at 110°C, dissolve in distilled water without carbon dioxide, and dilute to 1 liter. The pH value of this solution is 6.86 (25°C). 2.5 The pH value of the standard buffer solution at different temperatures is as follows: Temperature (°C)
3 Instrument
pH value of phosphoric acid type standard buffer solution
Temperature (°C)
pH meter: accurate to 0.1, requires temperature compensation or temperature calibration chart. 4 Instrument calibrationbzxZ.net
4.1 Glass electrode: Soak in distilled water for 24 hours before use. Phosphoric acid type standard buffer solution pH value
4.2 Saturated calomel electrode: The cavity of the electrode needs to be filled with saturated potassium chloride solution, and a small amount of potassium chloride crystals must be present at any temperature.
4.3 First adjust the pointer to zero, then put the electrode into the standard buffer solution, and adjust the pointer of the instrument to the pH value of the standard buffer solution at that temperature. Repeat twice. When the pH value reading of the standard buffer solution remains unchanged, the instrument can be used. 4.4 When calibrating the instrument, the standard buffer solution used should be as close as possible to the pH value of the object to be measured. If the zero point changes after continuous use for a long time, the zero point should be readjusted and calibrated according to the steps in 4.3. 5 Determination procedure
Take 0.5 ml of pesticide emulsifier in a 50 ml beaker and add 49.5 ml of distilled water. After stirring with a glass rod, put the calomel electrode and glass electrode into the solution to be measured and measure its pH value. If the pointer changes no more than 0.1 pH value within 2 minutes, the reading is the pH value of the sample.
Additional Notes:
GB 3776.2—83
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is technically managed by the Shenyang Chemical Research Institute of the Ministry of Chemical Industry. This standard was drafted by Nanjing Zhongshan Chemical Plant. The main drafters of this standard are Zhang Junzhi and Tao Deming. 612
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
Method of hydrogen ion concentrationdetermination for pesticide emulsifiers This method is applicable to the determination of hydrogen ion concentration of pesticide emulsifiers. 2 Reagents and solutions
2.1 Distilled water: pH value 6.5~7.0.
2.2 Potassium dihydrogen phosphate (GB1274-77): analytical grade. 2.3 Disodium hydrogen phosphate (GB1263--77): analytical grade. UDC 66.063.61
GB 3776.2-83
(confirmed in 1989)
2.4 Preparation of standard buffer solution: Weigh 3.04 g potassium dihydrogen phosphate and 3.55 g disodium hydrogen phosphate that have been dried to constant weight at 110°C, dissolve in distilled water without carbon dioxide, and dilute to 1 liter. The pH value of this solution is 6.86 (25°C). 2.5 The pH value of the standard buffer solution at different temperatures is as follows: Temperature (°C)
3 Instrument
pH value of phosphoric acid type standard buffer solution
Temperature (°C)
pH meter: accurate to 0.1, requires temperature compensation or temperature calibration chart. 4 Instrument calibrationbzxZ.net
4.1 Glass electrode: Soak in distilled water for 24 hours before use. Phosphoric acid type standard buffer solution pH value
4.2 Saturated calomel electrode: The cavity of the electrode needs to be filled with saturated potassium chloride solution, and a small amount of potassium chloride crystals must be present at any temperature.
4.3 First adjust the pointer to zero, then put the electrode into the standard buffer solution, and adjust the pointer of the instrument to the pH value of the standard buffer solution at that temperature. Repeat twice. When the pH value reading of the standard buffer solution remains unchanged, the instrument can be used. 4.4 When calibrating the instrument, the standard buffer solution used should be as close as possible to the pH value of the object to be measured. If the zero point changes after continuous use for a long time, the zero point should be readjusted and calibrated according to the steps in 4.3. 5 Determination procedure
Take 0.5 ml of pesticide emulsifier in a 50 ml beaker and add 49.5 ml of distilled water. After stirring with a glass rod, put the calomel electrode and glass electrode into the solution to be measured and measure its pH value. If the pointer changes no more than 0.1 pH value within 2 minutes, the reading is the pH value of the sample.
Additional Notes:
GB 3776.2—83
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is technically managed by the Shenyang Chemical Research Institute of the Ministry of Chemical Industry. This standard was drafted by Nanjing Zhongshan Chemical Plant. The main drafters of this standard are Zhang Junzhi and Tao Deming. 612
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG 21607-1996 Special-shaped shell and head
- JB/T 7905-1999 Sintered metal materials (excluding cemented carbide) Sampling
- JJG 30-2002 Verification Regulation Of Current Calipers
- GB/T 16561-1996 Container Equipment Delivery Note
- GB/T 11443.4-1989 General technical requirements for domestic satellite communication earth stations Part 4: TV/FM carrier channels
- JB/T 1698-1991 Stem nut (V)
- GB/T 39315.5-2020 General resource of military and civilian—Data model—Part 5:Person
- GB/T 7388-1999 Technical requirements for marine auxiliary anodes
- GB/T 15076.4-1994 Chemical analysis method of tantalum and niobium - Determination of iron content
- JB/T 3322-2002 Signal relay
- GB/T 5169.7-2001 Fire hazard test for electrical and electronic products - Diffusion and premixed flame test methods
- GB/T 5009.58-2003 Analytical methods for hygienic standards of polyethylene resins for food packaging
- JB/T 8714-1998 Centrifugal Spray Dryer
- QB/T 2711-2005 Physical and mechanical tests of leather - Determination of tearing force: Double-sided tearing
- JJF 1098-2003 Calibration Specification for Auto-measuring System of Thermocouples and Resistance Thermometers
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]