JB/T 3565-1992 Efficiency of long-axis centrifugal deep well pumps
time:
2024-08-04 02:23:42
- JB/T 3565-1992
- Abolished
Standard ID:
JB/T 3565-1992
Standard Name:
Efficiency of long-axis centrifugal deep well pumps
Chinese Name:
长轴离心深井泵 效率
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1992-12-25 -
Date of Implementation:
1993-07-01 -
Date of Expiration:
2007-04-01
China Standard Classification Number:
Machinery>>General Machinery and Equipment>>J71 Pump
alternative situation:
Replaces JB 3565-84; replaced by JB/T 3565-2006
Focal point Organization:
Shenyang Pump Research InstitutePublishing Department:
Shenyang Pump Research Institute
Skip to download
Summary:
This standard specifies the efficiency index of the working part of the long-axis centrifugal deep-well pump. This standard is applicable to pumps with flow rate Q=5~1500m3/h, specific speed ns=110~300 (or type number K=0.569~1.55). JB/T 3565-1992 Long-axis centrifugal deep-well pump efficiency JB/T3565-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
JB/T3565-92
Long-axis centrifugal deep-well pump
Issued on December 25, 1992
Implemented on July 1, 1993wwW.bzxz.Net
Issued by the Ministry of Machinery and Electronics Industry of the People's Republic of China
Mechanical Industry Standard of the People's Republic of China
Efficiency of long-axis centrifugal deep-well pump
Subject content and scope of application
This standard specifies the efficiency indicators of the working part of the long-axis centrifugal deep-well pump (hereinafter referred to as the "pump"). JB/T3565-92
Replaces JB3565-84
This standard applies to pumps with flow rate Q=5~1500m/h, specific speed n=110~300 (or type number K0.569~1.55). 2 Efficiency
2.1 The efficiency of the working part of the pump refers to the ratio of the output power of the working part of the pump to the input power (excluding the loss of the transmission shaft and the water pipe). It is a value based on clean water at normal temperature (0~40℃) as the medium. 2.2 The highest (or specified point) efficiency of the pump should not be lower than the curve A of Figure 1 or the provisions of column A in the following table. 2.3 Within the allowable working range of the pump, the efficiency of other points shall not be lower than the curve B of Figure 1 or the provisions of column B in the following table. 7%
Flow Q
405060
80100150200
Figure 1 Pump efficiency with n=110~210
30040050060080010001500
2.4 For the specific speed n, the pump efficiency in the range of 210~300 should be corrected according to the curve in Figure 2. Approved by the Ministry of Machinery and Electronics Industry on December 25, 1992, 900
Implemented on July 1, 1993
3 Application method
JB/T3565-92
Figure 2>210~300 pump efficiency correction value
Example 1: The flow rate Q=50m/h and the specific speed n=250 of the highest efficiency point (or specified point) of a long-axis centrifugal pump are Q=50m/h and n=250, and its efficiency value ni is calculated.
From the A column of the table or the A curve in Figure 1, the efficiency n=71.5% of Q50m/h is obtained, and the efficiency correction value An=1% of n=250 is obtained from Figure 2.
So: m=n-△n=71.5%-1%=70.5%. Example 2: The flow rate of a long-axis centrifugal pump at the highest efficiency point (or specified point) is the same as Example 1. Find the efficiency value 7z of the pump within the working range of Q=30m/h and n=230.
From the B column of the table or the B curve in Figure 1, the efficiency 7=63.5% for Q=30m/h is obtained, and the efficiency correction value n=0.5% for n=230 is obtained from Figure 2.
So: n=-A=63.5%-0.5%=63%.
Additional remarks:
This standard is proposed and managed by Shenyang Pump Research Institute. This standard is drafted by Shenyang Pump Research Institute. The main drafter of this standard is Zhang Lifu.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T3565-92
Long-axis centrifugal deep-well pump
Issued on December 25, 1992
Implemented on July 1, 1993wwW.bzxz.Net
Issued by the Ministry of Machinery and Electronics Industry of the People's Republic of China
Mechanical Industry Standard of the People's Republic of China
Efficiency of long-axis centrifugal deep-well pump
Subject content and scope of application
This standard specifies the efficiency indicators of the working part of the long-axis centrifugal deep-well pump (hereinafter referred to as the "pump"). JB/T3565-92
Replaces JB3565-84
This standard applies to pumps with flow rate Q=5~1500m/h, specific speed n=110~300 (or type number K0.569~1.55). 2 Efficiency
2.1 The efficiency of the working part of the pump refers to the ratio of the output power of the working part of the pump to the input power (excluding the loss of the transmission shaft and the water pipe). It is a value based on clean water at normal temperature (0~40℃) as the medium. 2.2 The highest (or specified point) efficiency of the pump should not be lower than the curve A of Figure 1 or the provisions of column A in the following table. 2.3 Within the allowable working range of the pump, the efficiency of other points shall not be lower than the curve B of Figure 1 or the provisions of column B in the following table. 7%
Flow Q
405060
80100150200
Figure 1 Pump efficiency with n=110~210
30040050060080010001500
2.4 For the specific speed n, the pump efficiency in the range of 210~300 should be corrected according to the curve in Figure 2. Approved by the Ministry of Machinery and Electronics Industry on December 25, 1992, 900
Implemented on July 1, 1993
3 Application method
JB/T3565-92
Figure 2>210~300 pump efficiency correction value
Example 1: The flow rate Q=50m/h and the specific speed n=250 of the highest efficiency point (or specified point) of a long-axis centrifugal pump are Q=50m/h and n=250, and its efficiency value ni is calculated.
From the A column of the table or the A curve in Figure 1, the efficiency n=71.5% of Q50m/h is obtained, and the efficiency correction value An=1% of n=250 is obtained from Figure 2.
So: m=n-△n=71.5%-1%=70.5%. Example 2: The flow rate of a long-axis centrifugal pump at the highest efficiency point (or specified point) is the same as Example 1. Find the efficiency value 7z of the pump within the working range of Q=30m/h and n=230.
From the B column of the table or the B curve in Figure 1, the efficiency 7=63.5% for Q=30m/h is obtained, and the efficiency correction value n=0.5% for n=230 is obtained from Figure 2.
So: n=-A=63.5%-0.5%=63%.
Additional remarks:
This standard is proposed and managed by Shenyang Pump Research Institute. This standard is drafted by Shenyang Pump Research Institute. The main drafter of this standard is Zhang Lifu.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 12122-1989 Quality assurance system of product package
- GB/T 21581-2008 Dangerous goods - Test method of steel tube drop for liquid
- SJ/T 10205-1991 General specification of airport surveillance primary radar for air traffic control
- GB/Z 18427-2001 Hydraulic hose assembly hydraulic system external leakage classification
- JB/T 4279.5-1994 Verification methods for testing instruments and equipment for enameled winding wires - Snap-break tester
- GB 2766-1995 General technical requirements for gill-penetrating hemostatic forceps
- GB/T 3098.10-1993 Mechanical properties of fasteners Bolts, screws, studs and nuts made of non-ferrous metals
- JJG 941-1998 Verification Regulation of Fluorescent Luminance Meter
- GB/T 8910.3-2004 Methods for measuring vibration of handles of hand-held portable power tools Part 3: Rock drills and rotary hammers
- GB/T 2828-1987 Sampling procedures and tables for lot-by-lot inspection by attributes (Apply to inspection of successive lots or batches)
- HG/T 3115-1998 Properties of borosilicate glass 3.3
- JB/T 2967.1-1999 Accuracy of cross-section woodworking circular saws
- QB/T 1575-1992 Industrial sewing machine GC type medium speed lockstitch sewing machine head
- JB/T 6949-1993 H170 series fully hydraulic tunnel drilling rig
- GB/T 15137-1994 Blank Detailed Specification for Bulk Effect Diodes
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com