JB/T 3565-1992 Efficiency of long-axis centrifugal deep well pumps
time:
2024-08-04 02:23:42
- JB/T 3565-1992
- Abolished
Standard ID:
JB/T 3565-1992
Standard Name:
Efficiency of long-axis centrifugal deep well pumps
Chinese Name:
长轴离心深井泵 效率
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1992-12-25 -
Date of Implementation:
1993-07-01 -
Date of Expiration:
2007-04-01
China Standard Classification Number:
Machinery>>General Machinery and Equipment>>J71 Pump
alternative situation:
Replaces JB 3565-84; replaced by JB/T 3565-2006
Focal point Organization:
Shenyang Pump Research InstitutePublishing Department:
Shenyang Pump Research Institute

Skip to download
Summary:
This standard specifies the efficiency index of the working part of the long-axis centrifugal deep-well pump. This standard is applicable to pumps with flow rate Q=5~1500m3/h, specific speed ns=110~300 (or type number K=0.569~1.55). JB/T 3565-1992 Long-axis centrifugal deep-well pump efficiency JB/T3565-1992 Standard download decompression password: www.bzxz.net

Some standard content:
Mechanical Industry Standard of the People's Republic of China
JB/T3565-92
Long-axis centrifugal deep-well pumpwww.bzxz.net
Issued on December 25, 1992
Implemented on July 1, 1993
Issued by the Ministry of Machinery and Electronics Industry of the People's Republic of China
Mechanical Industry Standard of the People's Republic of China
Efficiency of long-axis centrifugal deep-well pump
Subject content and scope of application
This standard specifies the efficiency indicators of the working part of the long-axis centrifugal deep-well pump (hereinafter referred to as the "pump"). JB/T3565-92
Replaces JB3565-84
This standard applies to pumps with flow rate Q=5~1500m/h, specific speed n=110~300 (or type number K0.569~1.55). 2 Efficiency
2.1 The efficiency of the working part of the pump refers to the ratio of the output power of the working part of the pump to the input power (excluding the loss of the transmission shaft and the water pipe). It is a value based on clean water at normal temperature (0~40℃) as the medium. 2.2 The highest (or specified point) efficiency of the pump should not be lower than the curve A of Figure 1 or the provisions of column A in the following table. 2.3 Within the allowable working range of the pump, the efficiency of other points shall not be lower than the curve B of Figure 1 or the provisions of column B in the following table. 7%
Flow Q
405060
80100150200
Figure 1 Pump efficiency with n=110~210
30040050060080010001500
2.4 For the specific speed n, the pump efficiency in the range of 210~300 should be corrected according to the curve in Figure 2. Approved by the Ministry of Machinery and Electronics Industry on December 25, 1992, 900
Implemented on July 1, 1993
3 Application method
JB/T3565-92
Figure 2>210~300 pump efficiency correction value
Example 1: The flow rate Q=50m/h and the specific speed n=250 of the highest efficiency point (or specified point) of a long-axis centrifugal pump are Q=50m/h and n=250, and its efficiency value ni is calculated.
From the A column of the table or the A curve in Figure 1, the efficiency n=71.5% of Q50m/h is obtained, and the efficiency correction value An=1% of n=250 is obtained from Figure 2.
So: m=n-△n=71.5%-1%=70.5%. Example 2: The flow rate of a long-axis centrifugal pump at the highest efficiency point (or specified point) is the same as Example 1. Find the efficiency value 7z of the pump within the working range of Q=30m/h and n=230.
From the B column of the table or the B curve in Figure 1, the efficiency 7=63.5% for Q=30m/h is obtained, and the efficiency correction value n=0.5% for n=230 is obtained from Figure 2.
So: n=-A=63.5%-0.5%=63%.
Additional remarks:
This standard is proposed and managed by Shenyang Pump Research Institute. This standard is drafted by Shenyang Pump Research Institute. The main drafter of this standard is Zhang Lifu.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T3565-92
Long-axis centrifugal deep-well pumpwww.bzxz.net
Issued on December 25, 1992
Implemented on July 1, 1993
Issued by the Ministry of Machinery and Electronics Industry of the People's Republic of China
Mechanical Industry Standard of the People's Republic of China
Efficiency of long-axis centrifugal deep-well pump
Subject content and scope of application
This standard specifies the efficiency indicators of the working part of the long-axis centrifugal deep-well pump (hereinafter referred to as the "pump"). JB/T3565-92
Replaces JB3565-84
This standard applies to pumps with flow rate Q=5~1500m/h, specific speed n=110~300 (or type number K0.569~1.55). 2 Efficiency
2.1 The efficiency of the working part of the pump refers to the ratio of the output power of the working part of the pump to the input power (excluding the loss of the transmission shaft and the water pipe). It is a value based on clean water at normal temperature (0~40℃) as the medium. 2.2 The highest (or specified point) efficiency of the pump should not be lower than the curve A of Figure 1 or the provisions of column A in the following table. 2.3 Within the allowable working range of the pump, the efficiency of other points shall not be lower than the curve B of Figure 1 or the provisions of column B in the following table. 7%
Flow Q
405060
80100150200
Figure 1 Pump efficiency with n=110~210
30040050060080010001500
2.4 For the specific speed n, the pump efficiency in the range of 210~300 should be corrected according to the curve in Figure 2. Approved by the Ministry of Machinery and Electronics Industry on December 25, 1992, 900
Implemented on July 1, 1993
3 Application method
JB/T3565-92
Figure 2>210~300 pump efficiency correction value
Example 1: The flow rate Q=50m/h and the specific speed n=250 of the highest efficiency point (or specified point) of a long-axis centrifugal pump are Q=50m/h and n=250, and its efficiency value ni is calculated.
From the A column of the table or the A curve in Figure 1, the efficiency n=71.5% of Q50m/h is obtained, and the efficiency correction value An=1% of n=250 is obtained from Figure 2.
So: m=n-△n=71.5%-1%=70.5%. Example 2: The flow rate of a long-axis centrifugal pump at the highest efficiency point (or specified point) is the same as Example 1. Find the efficiency value 7z of the pump within the working range of Q=30m/h and n=230.
From the B column of the table or the B curve in Figure 1, the efficiency 7=63.5% for Q=30m/h is obtained, and the efficiency correction value n=0.5% for n=230 is obtained from Figure 2.
So: n=-A=63.5%-0.5%=63%.
Additional remarks:
This standard is proposed and managed by Shenyang Pump Research Institute. This standard is drafted by Shenyang Pump Research Institute. The main drafter of this standard is Zhang Lifu.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 9164-2001 Spherical plain bearings Angular contact spherical plain bearings
- GB/T 4678.5-2003 Die casting parts Part 5: Guide pins with head
- SY/T 5587.9-1993 Procedure for replacing wellhead equipment during routine workover of oil and water wells
- HG/T 3123-1998 Technical requirements for tire strength, bead unseating and static load testing machines
- MT/T 154.9-1996 Coal screening equipment model compilation method
- GB 12337-1998 Steel spherical storage tanks
- GB/T 27405-2008 Criterion on quality control of laboratories - Microbiological testing of food
- DL/T 575.11-1999 Ergonomic principles for the design of control centres Part 11: Principles for the evaluation of control rooms
- GB/T 15663.10-1995 Coal mining technology terminology mining machinery
- GB 9103-1988 Industrial stearic acid
- GB/T 14599-1993 High purity oxygen
- SY/T 5594-1993 Method for compiling development planning for water-flooded sandstone oilfields
- GB 16395-1996 Standard for determination and division of Kaschin-Beck disease areas
- GB/T 15828-1995 V-belt and multi-V belt drive--Dynamic determination of pitch line position
- HG/T 20570.1-1995 Determination of design pressure and design temperature of equipment and piping systems
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com