
JB/T 4279.5-1994 Verification methods for testing instruments and equipment for enameled winding wires - Snap-break tester
time:
2024-06-12 10:13:53
- JB/T 4279.5-1994
- Abolished
Standard ID:
JB/T 4279.5-1994
Standard Name:
Verification methods for testing instruments and equipment for enameled winding wires - Snap-break tester
Chinese Name:
漆包绕组线试验仪器设备检定方法 急拉断试验仪
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1994-12-09 -
Date of Implementation:
1995-06-01 -
Date of Expiration:
2008-07-01
China Standard Classification Number:
Electrical>>Electrical Production Equipment>>K91 Electrical Material Production Equipment
alternative situation:
Replaces JB 4279.5-1986; replaced by JB/T 4279.5-2008
Drafter:
Zhu BingDrafting Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryFocal point Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryProposing Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryPublishing Department:
Ministry of Machinery Industry of the People's Republic of China

Skip to download
Summary:
This standard specifies the verification items and technical requirements, verification instruments, verification force and method, verification results and treatment of enameled round wire quick break tester. This standard applies to the verification of enameled round wire quick break tester. JB/T 4279.5-1994 Verification method of enameled winding wire test equipment Quick break tester JB/T4279.5-1994 Standard download decompression password: www.bzxz.net

Some standard content:
Mechanical Industry Standard of the People's Republic of China
Verification Method of Enameled Winding Wire Test Instrument and Equipment Snap-Tear Tester
1 Subject Content and Scope of Application
JB/T4279.5-94
Replaces JB4279.5-86
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and processing of enameled round wire snap-tear tester.
This standard is applicable to the verification of enameled round wire snap-tear tester. 2 Reference Standards
JB/T4279.1 General Rules for Verification Method of Enameled Winding Wire Test Instrument and Equipment 3 Verification Items and Technical Requirements
3.1 The starting distance between the two clamps should be 250±1mm. 3.2 When pulling the specimen quickly, there should be no slipping and movement. 3.3 The quick pulling speed should be greater than 2m/s.
4 Calibration instruments
4.1 Vernier caliper, 300mm, graduation value 0.02mm; or steel tape measure. Q-1 Enameled wire test instrument detector.
5 Calibration method
Use a vernier caliper to measure the starting distance between the two tools. 5.1
5.2 Use samples with nominal conductor diameters of 0.05mm and 1.0mm to conduct a quick pull test and check whether the samples have any slipping or movement. 5.3 Determine the quick pull speed.
The measurement is carried out when the tester is unloaded (without samples). 5.3.1
Measure the quick pull speed
Fix a 10±0.1mm wide metal sheet on a movable fixture. During the quick pull, while the metal sheet is exposed to light, a pulse signal is output through a photoelectric controller. The number of pulses n is determined by the Q-1 Enameled wire test instrument detector. b. Measure three times at the starting, middle and end positions of the movable fixture's moving stroke. 5.3.3 Calculate the quick pull speed
Calculate the quick pull speed for each measurement at each measuring position: Where; V quick pull speed, m/s;
V1000/n
Q-1 enameled wire tester reading. b. Calculate the average of the three calculated values at each measuring position; c. Take the maximum value of the three average values for the quick pull speed. 5.3.4 Care should be taken to avoid the counting error of the Q-1 enameled wire tester due to electrical interference during measurement. Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Handling of verification results
JB/T4279.5-94
6.1 A verification certificate shall be issued to qualified enameled round wire quick break testers, and a verification result notice shall be issued to unqualified ones. The cover forms of the verification certificate and verification result notice are shown in the appendix of JB/T4279.1. 6.2 The verification cycle of enameled round wire quick break testers is generally set at 2 years. Additional remarks:bZxz.net
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. The main drafter of this standard is Zhu Bing.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Verification Method of Enameled Winding Wire Test Instrument and Equipment Snap-Tear Tester
1 Subject Content and Scope of Application
JB/T4279.5-94
Replaces JB4279.5-86
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and processing of enameled round wire snap-tear tester.
This standard is applicable to the verification of enameled round wire snap-tear tester. 2 Reference Standards
JB/T4279.1 General Rules for Verification Method of Enameled Winding Wire Test Instrument and Equipment 3 Verification Items and Technical Requirements
3.1 The starting distance between the two clamps should be 250±1mm. 3.2 When pulling the specimen quickly, there should be no slipping and movement. 3.3 The quick pulling speed should be greater than 2m/s.
4 Calibration instruments
4.1 Vernier caliper, 300mm, graduation value 0.02mm; or steel tape measure. Q-1 Enameled wire test instrument detector.
5 Calibration method
Use a vernier caliper to measure the starting distance between the two tools. 5.1
5.2 Use samples with nominal conductor diameters of 0.05mm and 1.0mm to conduct a quick pull test and check whether the samples have any slipping or movement. 5.3 Determine the quick pull speed.
The measurement is carried out when the tester is unloaded (without samples). 5.3.1
Measure the quick pull speed
Fix a 10±0.1mm wide metal sheet on a movable fixture. During the quick pull, while the metal sheet is exposed to light, a pulse signal is output through a photoelectric controller. The number of pulses n is determined by the Q-1 Enameled wire test instrument detector. b. Measure three times at the starting, middle and end positions of the movable fixture's moving stroke. 5.3.3 Calculate the quick pull speed
Calculate the quick pull speed for each measurement at each measuring position: Where; V quick pull speed, m/s;
V1000/n
Q-1 enameled wire tester reading. b. Calculate the average of the three calculated values at each measuring position; c. Take the maximum value of the three average values for the quick pull speed. 5.3.4 Care should be taken to avoid the counting error of the Q-1 enameled wire tester due to electrical interference during measurement. Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Handling of verification results
JB/T4279.5-94
6.1 A verification certificate shall be issued to qualified enameled round wire quick break testers, and a verification result notice shall be issued to unqualified ones. The cover forms of the verification certificate and verification result notice are shown in the appendix of JB/T4279.1. 6.2 The verification cycle of enameled round wire quick break testers is generally set at 2 years. Additional remarks:bZxz.net
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. The main drafter of this standard is Zhu Bing.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- MT/T 662-1997 Basic dimensions of nozzles for spray dust suppression in drum coal mining machines
- JB/T 10400.1-2004 Gearbox for off-grid wind turbine generator system Part 1: Technical requirements
- JB/T 5267-1991 Vacuum tube high frequency induction heating power supply device
- GB/T 4789.7-2003 Microbiological examination of food hygiene - Examination of Vibrio parahaemolyticus
- GB/T 4324.14-1984 Chemical analysis of tungsten - Determination of calcium content by atomic absorption spectrophotometry
- HG/T 2496-1993 Bleaching powder
- GB/T 5009.95-2003 Determination of tetracycline antibiotic residues in honey
- QB/T 1658.3-2002 Clarinet
- JB/T 6457.1-2004 Small valve-regulated sealed lead-acid batteries Part 1: Product classification
- JB/T 9162.41-1999 Dimensions of cylinder dial indicator actuators
- JB/T 10121-1999 Machine tool fixture parts and components - Quick-change chucks for lathes
- QB/T 2141.1-1995 Daily knife
- GB 18450-2001 Civilian black powder
- GBJ 25-1990 Building Code for Collapsible Loess Areas GBJ25-90
- GB/T 15885-1995 Fixed resistors for use in electronic equipment Part 4: Blank detail specification: Power type fixed resistors Assessment level F
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com