JB/T 4279.5-1994 Verification methods for testing instruments and equipment for enameled winding wires - Snap-break tester
time:
2024-06-12 10:13:53
- JB/T 4279.5-1994
- Abolished
Standard ID:
JB/T 4279.5-1994
Standard Name:
Verification methods for testing instruments and equipment for enameled winding wires - Snap-break tester
Chinese Name:
漆包绕组线试验仪器设备检定方法 急拉断试验仪
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1994-12-09 -
Date of Implementation:
1995-06-01 -
Date of Expiration:
2008-07-01
China Standard Classification Number:
Electrical>>Electrical Production Equipment>>K91 Electrical Material Production Equipment
alternative situation:
Replaces JB 4279.5-1986; replaced by JB/T 4279.5-2008
Drafter:
Zhu BingDrafting Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryFocal point Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryProposing Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryPublishing Department:
Ministry of Machinery Industry of the People's Republic of China
Skip to download
Summary:
This standard specifies the verification items and technical requirements, verification instruments, verification force and method, verification results and treatment of enameled round wire quick break tester. This standard applies to the verification of enameled round wire quick break tester. JB/T 4279.5-1994 Verification method of enameled winding wire test equipment Quick break tester JB/T4279.5-1994 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
Verification Method of Enameled Winding Wire Test Instrument and Equipment Snap-Tear Tester
1 Subject Content and Scope of Application
JB/T4279.5-94
Replaces JB4279.5-86
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and processing of enameled round wire snap-tear tester.
This standard is applicable to the verification of enameled round wire snap-tear tester. 2 Reference Standards
JB/T4279.1 General Rules for Verification Method of Enameled Winding Wire Test Instrument and Equipment 3 Verification Items and Technical Requirements
3.1 The starting distance between the two clamps should be 250±1mm. 3.2 When pulling the specimen quickly, there should be no slipping and movement. 3.3 The quick pulling speed should be greater than 2m/s.
4 Calibration instrumentsbZxz.net
4.1 Vernier caliper, 300mm, graduation value 0.02mm; or steel tape measure. Q-1 Enameled wire test instrument detector.
5 Calibration method
Use a vernier caliper to measure the starting distance between the two tools. 5.1
5.2 Use samples with nominal conductor diameters of 0.05mm and 1.0mm to conduct a quick pull test and check whether the samples have any slipping or movement. 5.3 Determine the quick pull speed.
The measurement is carried out when the tester is unloaded (without samples). 5.3.1
Measure the quick pull speed
Fix a 10±0.1mm wide metal sheet on a movable fixture. During the quick pull, while the metal sheet is exposed to light, a pulse signal is output through a photoelectric controller. The number of pulses n is determined by the Q-1 Enameled wire test instrument detector. b. Measure three times at the starting, middle and end positions of the movable fixture's moving stroke. 5.3.3 Calculate the quick pull speed
Calculate the quick pull speed for each measurement at each measuring position: Where; V quick pull speed, m/s;
V1000/n
Q-1 enameled wire tester reading. b. Calculate the average of the three calculated values at each measuring position; c. Take the maximum value of the three average values for the quick pull speed. 5.3.4 Care should be taken to avoid the counting error of the Q-1 enameled wire tester due to electrical interference during measurement. Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Handling of verification results
JB/T4279.5-94
6.1 A verification certificate shall be issued to qualified enameled round wire quick break testers, and a verification result notice shall be issued to unqualified ones. The cover forms of the verification certificate and verification result notice are shown in the appendix of JB/T4279.1. 6.2 The verification cycle of enameled round wire quick break testers is generally set at 2 years. Additional remarks:
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. The main drafter of this standard is Zhu Bing.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Verification Method of Enameled Winding Wire Test Instrument and Equipment Snap-Tear Tester
1 Subject Content and Scope of Application
JB/T4279.5-94
Replaces JB4279.5-86
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and processing of enameled round wire snap-tear tester.
This standard is applicable to the verification of enameled round wire snap-tear tester. 2 Reference Standards
JB/T4279.1 General Rules for Verification Method of Enameled Winding Wire Test Instrument and Equipment 3 Verification Items and Technical Requirements
3.1 The starting distance between the two clamps should be 250±1mm. 3.2 When pulling the specimen quickly, there should be no slipping and movement. 3.3 The quick pulling speed should be greater than 2m/s.
4 Calibration instrumentsbZxz.net
4.1 Vernier caliper, 300mm, graduation value 0.02mm; or steel tape measure. Q-1 Enameled wire test instrument detector.
5 Calibration method
Use a vernier caliper to measure the starting distance between the two tools. 5.1
5.2 Use samples with nominal conductor diameters of 0.05mm and 1.0mm to conduct a quick pull test and check whether the samples have any slipping or movement. 5.3 Determine the quick pull speed.
The measurement is carried out when the tester is unloaded (without samples). 5.3.1
Measure the quick pull speed
Fix a 10±0.1mm wide metal sheet on a movable fixture. During the quick pull, while the metal sheet is exposed to light, a pulse signal is output through a photoelectric controller. The number of pulses n is determined by the Q-1 Enameled wire test instrument detector. b. Measure three times at the starting, middle and end positions of the movable fixture's moving stroke. 5.3.3 Calculate the quick pull speed
Calculate the quick pull speed for each measurement at each measuring position: Where; V quick pull speed, m/s;
V1000/n
Q-1 enameled wire tester reading. b. Calculate the average of the three calculated values at each measuring position; c. Take the maximum value of the three average values for the quick pull speed. 5.3.4 Care should be taken to avoid the counting error of the Q-1 enameled wire tester due to electrical interference during measurement. Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Handling of verification results
JB/T4279.5-94
6.1 A verification certificate shall be issued to qualified enameled round wire quick break testers, and a verification result notice shall be issued to unqualified ones. The cover forms of the verification certificate and verification result notice are shown in the appendix of JB/T4279.1. 6.2 The verification cycle of enameled round wire quick break testers is generally set at 2 years. Additional remarks:
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. The main drafter of this standard is Zhu Bing.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 10353.1-2002 Technical requirements for flameproof motors for fuel dispensers Part 1: YBJY series flameproof three-phase asynchronous motors for fuel dispensers (frame sizes 63 to 100)
- JB/T 3411.92-1999 7:24 Dimensions of adjustable boring tool holders with taper shank
- JJF 1110-2003 Calibration Specification for Construction Quality Tester Sets
- GB/T 15271-1994 Information generated by identification cards and the content of financial transactions
- SY/T 0531-1994 Determination of suspended particles in water injected into oil fields - Resistance induction method
- JB/T 9904.3-1999 Technical requirements for spline shaft grinding machines
- SJ 3160-1988 Sockets for colour picture tubes,Type GZS8-6-2
- HG 3017-1988 Determination of chlorine content of chlorinated paraffins - Mercury titration method
- QB/T 2443-1999 Steel measuring tape
- GB 16186-1996 Hygienic standard for cypermethrin in workshop air
- JB/T 2001.48-1999 Air gate valve for water system pump station (PN=31.5MPa)
- GB/T 2951.25-1994 Test methods for mechanical and physical properties of wires and cables - Anaerobic bacterial corrosion test for outer sheath
- JB/T 7890-1999 Fan coal mill
- GB/T 4857.7-2005 Packaging—Basic tests for transport packages—Part 7:Sinusoidal vibration test method at constant frequency
- JB/T 7993-1999 Chemical analysis method of boron carbide