
JB/T 5784-1991 Test method for closed type glow plugs
time:
2024-06-25 15:35:01
- JB/T 5784-1991
- in force
Standard ID:
JB/T 5784-1991
Standard Name:
Test method for closed type glow plugs
Chinese Name:
封闭型电热塞 试验方法
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1991-10-17 -
Date of Implementation:
1992-10-01
China Standard Classification Number:
Vehicles>>Automotive Electronics, Electrical Equipment and Instruments>>T37 Ignition Device
alternative situation:
JB3259-83Procurement status:
eqv ISO 7578:1986
Focal point Organization:
Nanjing Spark Plug Research InstitutePublishing Department:
Nanjing Spark Plug Research Institute

Skip to download
Summary:
This standard partially replaces JB 3259-83. This standard specifies the test method for enclosed glow plugs. This standard applies to the test of enclosed glow plugs. JB/T 5784-1991 Test method for enclosed glow plugs JB/T5784-1991 Standard download decompression password: www.bzxz.net

Some standard content:
Mechanical Industry Standard of the People's Republic of China
JB/T 5784-1991
Test Method for Sealed Glow Plugs
Published on October 17, 1991
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on October 1, 1992
Mechanical Industry Standard of the People's Republic of China
Test Method for Sealed Glow Plugs
1 Subject Content and Scope of Application
This standard specifies the test method for sealed glow plugs. This standard applies to the test of sealed glow plugs. 2 Test Items and Methods
2.1 Appearance and Dimension Inspection
Appearance inspection is carried out visually.
JB/T5784-1991
Partially replaces JB3259-83
Dimension inspection is carried out with a vernier caliper with an accuracy of 0.02mm or other measuring instruments and special measuring tools with corresponding accuracy. 2.2 Sealing performance
Install the sample on a special device and apply a gas pressure of 4MPa (40.8kgf/cm2). When there is no gas leakage between the sample and the device, use the drainage gas collection method or other corresponding methods to check whether there is continuous leakage. 2.3 Cold resistance
a. The test should be carried out at room temperature of 23±5℃. b. Use a single-arm bridge or an instrument of corresponding accuracy (the change of the current passing through the glow plug after 1 minute is not more than 2%) to measure the resistance value between the sample terminal and the shell.
2.4 Temperature rise test
a. The test should be carried out at room temperature of 23±5℃; b. The sample should be heated at rated voltage and cooled to room temperature after 0.5~1min; c. The sample after test b shall be installed on a special cooling device to keep the temperature of the sealing seat of the glow plug shell below 30℃;
d. Connect the sample to the device as specified in Figure 1, apply rated voltage ±0.1V (measurement should be made when the voltage is stable), and then measure the time required for the temperature to reach 850℃ and 1000℃ within 8mm of the end of the heating element. Non-contact temperature measurement method or other appropriate methods can also be used for temperature measurement.
Approved by the Ministry of Machinery and Electronics Industry on October 17, 1991 and implemented on October 1, 1992Www.bzxZ.net
In the figure: E-
DC regulated power supply;
A0.5-level ammeter:
0.5-level voltmeter:
1——Sample:
JB/T 57841991
2——Nickel-chromium, nickel-silicon thermocouple with a diameter not greater than 0.3mm:3——Temperature recorder
2.5 Working current
a. The test should be carried out at room temperature of 23±5℃. b. Install the sample on the device specified in Figure 2, apply the rated voltage ±0.1V (measured when the voltage is stable), and read the indication value of the ammeter at the specified time.
In the figure: E-
DC regulated power supply:
0.5-level ammeter:
0.5-level voltmeter:
K-—Switch:
One sample
2.6 Overvoltage test
JB/T5784-1991
Install the sample on the device specified in Figure 2, apply 125% of the rated voltage, cut off the power supply after 15s, and let the sample cool to room temperature. Then measure the temperature and working current of the sample according to the test methods specified in 2.4 and 2.5. 2.7 Overload test
Install the sample on the device specified in Figure 2. As shown in Figure 3, apply the rated voltage and the test voltage of 110% and 115% of the rated voltage respectively, then cut off the power supply and let the sample cool to room temperature. Then measure the temperature and working current of the sample according to the test methods specified in 2.4 and 2.5.
2745678
2.8 Power-off and power-on test
a: Install the sample on a special cooling device to keep the temperature of the sealing seat of the glow plug shell below 30℃; b. Connect the sample to the test device specified in Figure 2, apply a test voltage 10% higher than the rated voltage, and perform power-off and power-on tests for the specified time.
Additional instructions:
This standard was proposed and managed by the Nanjing Spark Plug Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by the Nanjing Spark Plug Research Institute. The main drafters of this standard are Gao Fenggang, Zhang Minsheng, and Ni Lingzhen. 3
People's Republic of China
Mechanical Industry Standard
Test Method for Sealed Glow Plugs
JB/T 57841991
Published and issued by the China Academy of Mechanical Science
Printed by the China Academy of Mechanical Science
(No. 2 Shouti South Road, Beijing
Postal Code 100044)
Format 880×1230
Sheet 1/2
Word Count 6,000
First Edition in May 1992
First Printing in May 1992
Print Quantity 1-500
Price 2.00 Yuan
Mechanical Industry Standard Service Network: http://swww.JB.ac.cn1661_8
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T 5784-1991
Test Method for Sealed Glow Plugs
Published on October 17, 1991
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on October 1, 1992
Mechanical Industry Standard of the People's Republic of China
Test Method for Sealed Glow Plugs
1 Subject Content and Scope of Application
This standard specifies the test method for sealed glow plugs. This standard applies to the test of sealed glow plugs. 2 Test Items and Methods
2.1 Appearance and Dimension Inspection
Appearance inspection is carried out visually.
JB/T5784-1991
Partially replaces JB3259-83
Dimension inspection is carried out with a vernier caliper with an accuracy of 0.02mm or other measuring instruments and special measuring tools with corresponding accuracy. 2.2 Sealing performance
Install the sample on a special device and apply a gas pressure of 4MPa (40.8kgf/cm2). When there is no gas leakage between the sample and the device, use the drainage gas collection method or other corresponding methods to check whether there is continuous leakage. 2.3 Cold resistance
a. The test should be carried out at room temperature of 23±5℃. b. Use a single-arm bridge or an instrument of corresponding accuracy (the change of the current passing through the glow plug after 1 minute is not more than 2%) to measure the resistance value between the sample terminal and the shell.
2.4 Temperature rise test
a. The test should be carried out at room temperature of 23±5℃; b. The sample should be heated at rated voltage and cooled to room temperature after 0.5~1min; c. The sample after test b shall be installed on a special cooling device to keep the temperature of the sealing seat of the glow plug shell below 30℃;
d. Connect the sample to the device as specified in Figure 1, apply rated voltage ±0.1V (measurement should be made when the voltage is stable), and then measure the time required for the temperature to reach 850℃ and 1000℃ within 8mm of the end of the heating element. Non-contact temperature measurement method or other appropriate methods can also be used for temperature measurement.
Approved by the Ministry of Machinery and Electronics Industry on October 17, 1991 and implemented on October 1, 1992Www.bzxZ.net
In the figure: E-
DC regulated power supply;
A0.5-level ammeter:
0.5-level voltmeter:
1——Sample:
JB/T 57841991
2——Nickel-chromium, nickel-silicon thermocouple with a diameter not greater than 0.3mm:3——Temperature recorder
2.5 Working current
a. The test should be carried out at room temperature of 23±5℃. b. Install the sample on the device specified in Figure 2, apply the rated voltage ±0.1V (measured when the voltage is stable), and read the indication value of the ammeter at the specified time.
In the figure: E-
DC regulated power supply:
0.5-level ammeter:
0.5-level voltmeter:
K-—Switch:
One sample
2.6 Overvoltage test
JB/T5784-1991
Install the sample on the device specified in Figure 2, apply 125% of the rated voltage, cut off the power supply after 15s, and let the sample cool to room temperature. Then measure the temperature and working current of the sample according to the test methods specified in 2.4 and 2.5. 2.7 Overload test
Install the sample on the device specified in Figure 2. As shown in Figure 3, apply the rated voltage and the test voltage of 110% and 115% of the rated voltage respectively, then cut off the power supply and let the sample cool to room temperature. Then measure the temperature and working current of the sample according to the test methods specified in 2.4 and 2.5.
2745678
2.8 Power-off and power-on test
a: Install the sample on a special cooling device to keep the temperature of the sealing seat of the glow plug shell below 30℃; b. Connect the sample to the test device specified in Figure 2, apply a test voltage 10% higher than the rated voltage, and perform power-off and power-on tests for the specified time.
Additional instructions:
This standard was proposed and managed by the Nanjing Spark Plug Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by the Nanjing Spark Plug Research Institute. The main drafters of this standard are Gao Fenggang, Zhang Minsheng, and Ni Lingzhen. 3
People's Republic of China
Mechanical Industry Standard
Test Method for Sealed Glow Plugs
JB/T 57841991
Published and issued by the China Academy of Mechanical Science
Printed by the China Academy of Mechanical Science
(No. 2 Shouti South Road, Beijing
Postal Code 100044)
Format 880×1230
Sheet 1/2
Word Count 6,000
First Edition in May 1992
First Printing in May 1992
Print Quantity 1-500
Price 2.00 Yuan
Mechanical Industry Standard Service Network: http://swww.JB.ac.cn1661_8
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 19157-2003 General technical requirements for remote-controlled fire monitor systems
- GB/T 8196-2003 Mechanical safety guards General requirements for the design and manufacture of fixed and movable guards
- HG 21519-1995 Vertical hanging cover plate type flat welding flange manhole. Attached picture
- JB/T 9950-1999 Parameters of woodworking sawing machine with movable worktable
- GB/T 15663.2-1995 Coal mine scientific and technological terminology shaft and tunnel engineering
- GB 3089-1982 Stainless acid-resistant steel plate thin-walled seamless steel pipe
- GB 6529-1986 Standard atmospheres for conditioning and testing textiles
- JB/T 58651.3-1999 Fastener product quality classification stud
- JB/T 8327-1996 Accuracy of instrument turret lathe
- JB/T 4403-1999 Compacted graphite iron castings
- QB/T 1572-1992 General technical requirements for electroplating of sewing machine parts
- HG/T 3106-1988 Inner tube vulcanizing press
- JB/T 7085.2-1993 Guidelines for stator and rotor winding process of series-excited motors for power tools Part 2: Rotor symmetric winding process
- JB/T 9159.8-1999 Single-axis longitudinal cutting automatic lathe auxiliary tool tap sleeve A-type dimensions
- GB/T 9649.32-2001 The terminology classification codes of geology and mineral resoures--The prospecting and exploration of solid mineral resources
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com