JB/T 2001.21-1999 Water system centralized air release valve (PN=31.5MPa)
time:
2024-08-14 15:19:22
- JB/T 2001.21-1999
- in force
Standard ID:
JB/T 2001.21-1999
Standard Name:
Water system centralized air release valve (PN=31.5MPa)
Chinese Name:
水系统 集中放气阀(PN=31.5MPa)
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1999-06-28 -
Date of Implementation:
2000-01-01
Standard ICS number:
Fluid systems and general parts >> 23.100 Fluid power systemsChina Standard Classification Number:
Machinery>>General Parts>>J20 Hydraulic and Pneumatic Devices
alternative situation:
JB 2021-1984
Focal point Organization:
Metallurgical Equipment Standardization Technical CommitteePublishing Department:
Metallurgical Equipment Standardization Technical Committee
Skip to download
Summary:
JB/T 2001.21-1999 This standard is a revision of JB 2021-84 "Type and size of centralized air release valve for hydraulic presses (Pg=315×100000Pa)". This standard specifies the type, size and technical requirements of centralized air release valves for water systems. This standard is applicable to centralized air release valves used in high-altitude and underground working cylinders, pipelines, etc. with a nominal pressure of 31.5MPa and inconvenient to operate during decentralized air release. This standard was first published on January 1, 1984. JB/T 2001.21-1999 Centralized air release valve for water systems (PN=31.5MPa) JB/T2001.21-1999 Standard download decompression password: www.bzxz.net
Some standard content:
IC.s$ 23.110
Standard of the Machinery Industry of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system components
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(-01-U1 Implementation
Standard of the Machinery Industry of the People's Republic of China
Water system
Central air escape valve
Type and size
Watcr system-manifold air-escape-Typenndsize
[PN=31.5 MPa]
Added the type, size and technical requirements of the air release valve used in the water system. JB/T2001.21—1999
Represented 1221—34
Small standard with 31.5MPa, the inconvenience of gas exploration in high altitude underground cylinders, pipelines, etc. The centralized air release valve
? The referenced standards
1 are included in the marked clauses, which constitute the clauses of this standard through reference in this standard. When this standard is published, the full version shown is valid. All standard parts will be revised, and the parties using this standard should discuss and use them as soon as possible. The possibility of a new version of the standard is listed. J2T2001201999 Water System Centralized 1 Air Release Valve Core [PN = 31.5MPa] 3 Types and Sizes
3.1 The standard adopts 014×3m! According to the number of air release valves, there are two types: Type 1: a nested air release valve core [see Figure]: Type 1: a centralized air release adjustment core (Figure 1. 3.2 The size should comply with the provisions of 1 and 1
3.3 Figure 1 + 2! The central air valve core" is in accordance with the provisions of 1B/2001.20. Table
22001.2:.1
J3.T 2001.21.2
China Machinery Industry Bureau approved on 1999-06-28 4
2000-01-1 implementation
4 Technical requirements
1B/2001.21-1999bzxz.net
[-body: 2-centralized venting core; 3-accumulation period connection.1
4.1 Nominal 3].5MPu, test pressure 42MPa. 4.2 The body and the core are tested together to check the valve strength and tightness. The test method is shown in the technical specification of HT2001.20. Example of centralized venting valve: centralized venting type 1 J3/T2001.21-1999
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Standard of the Machinery Industry of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system components
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(-01-U1 Implementation
Standard of the Machinery Industry of the People's Republic of China
Water system
Central air escape valve
Type and size
Watcr system-manifold air-escape-Typenndsize
[PN=31.5 MPa]
Added the type, size and technical requirements of the air release valve used in the water system. JB/T2001.21—1999
Represented 1221—34
Small standard with 31.5MPa, the inconvenience of gas exploration in high altitude underground cylinders, pipelines, etc. The centralized air release valve
? The referenced standards
1 are included in the marked clauses, which constitute the clauses of this standard through reference in this standard. When this standard is published, the full version shown is valid. All standard parts will be revised, and the parties using this standard should discuss and use them as soon as possible. The possibility of a new version of the standard is listed. J2T2001201999 Water System Centralized 1 Air Release Valve Core [PN = 31.5MPa] 3 Types and Sizes
3.1 The standard adopts 014×3m! According to the number of air release valves, there are two types: Type 1: a nested air release valve core [see Figure]: Type 1: a centralized air release adjustment core (Figure 1. 3.2 The size should comply with the provisions of 1 and 1
3.3 Figure 1 + 2! The central air valve core" is in accordance with the provisions of 1B/2001.20. Table
22001.2:.1
J3.T 2001.21.2
China Machinery Industry Bureau approved on 1999-06-28 4
2000-01-1 implementation
4 Technical requirements
1B/2001.21-1999bzxz.net
[-body: 2-centralized venting core; 3-accumulation period connection.1
4.1 Nominal 3].5MPu, test pressure 42MPa. 4.2 The body and the core are tested together to check the valve strength and tightness. The test method is shown in the technical specification of HT2001.20. Example of centralized venting valve: centralized venting type 1 J3/T2001.21-1999
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JG/T 3060-1999 Composite steel formwork
- GB/T 17980.101-2004 Pesticide-Guidelines for the field efficacy trials(II)-Part 101:Fungicides against pineappleal disease of sugarcane
- SY/T 5270-2000 Technical regulations for the design of high-pressure water injection pipeline accessories
- JB/T 7217-1994 General technical requirements for coating of separation machinery
- JB/T 7925.1-1995 Sliding bearings Single-layer bearing anti-friction alloy hardness test method
- HG/T 2365-1992 Determination of moisture content of poly(alkylene terephthalate) pellets
- JB/T 9918.2-1999 Technical requirements for high precision hob grinders
- GB/T 3171.2-1982 Determination of bulk density of aluminium powder - Volumetric method
- GB/T 27936-2011 Publication distribution terminology
- HG/T 3119-1998 Tire curing press test method
- GB 16915.3-2000 Switches for household and similar fixed electrical installations Part 2: Particular requirements Section 2: Remote control switches (RCS)
- SY/T 6537-2002 Gas and solution analysis methods for natural gas purification plants