JB/T 6433-1992 Types and basics of large and medium-sized vertical mixed-flow pumps
time:
1992-07-20 15:00:00
- JB/T 6433-1992
- Abolished
Standard ID:
JB/T 6433-1992
Standard Name:
Types and basics of large and medium-sized vertical mixed-flow pumps
Chinese Name:
大、中型立式混流泵 型式与基
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1992-07-20 -
Date of Implementation:
1993-01-01 -
Date of Expiration:
2007-03-01
China Standard Classification Number:
Machinery>>General Machinery and Equipment>>J71 Pump
alternative situation:
Replaced by JB/T 6433-2006
Skip to download
Summary:
This standard specifies the types and basic parameters of large and medium-sized vertical mixed-flow pumps. JB/T 6433-1992 Types and bases of large and medium-sized vertical mixed-flow pumps JB/T6433-1992 Standard download and decompression password: www.bzxz.net
Some standard content:
J71 | | tt | | JB | |tt||Released on 1992-07-20
Implemented by the Ministry of Mechanical and Electronics Industry of the People's Republic of China on 1993-01-01
Released
Machinery Industry Standards of the People's Republic of China
Large and medium-sized vertical mixed-flow pumps
Types and basic parameters
1 Subject content and scope of application
This standard specifies the types of large and medium-sized vertical mixed-flow pumps (hereinafter referred to as "\ and basic parameters. JB/T643392
This standard is applicable to tickets for transporting clean water or other liquids with physical properties similar to water. The temperature of the transported liquid is not higher than 50C. 2 Reference Standards
GB/ T13008 mixed flow pump and axial flow pump technical conditions 3 types and basic parameters
3.1.1 According to the inspection and disassembly type, it is divided into:
Extractable type:
non-extractable,
3.1.2 Press water chamber types are divided into:
b.||tt ||Guide vane type:
Vortex type
According to the blade adjustment type:
b.| |tt||e.
Fixed type:
Rate adjustment type:
Fully adjustable type.
Inlet channel type
3.1.4| |tt||The pump inlet adopts a trumpet-shaped inlet channel. When the nominal diameter of the discharge port is greater than 1200mm, a square inlet channel can be used. 3.1.5 Minimum water inlet level
The pump inlet should be filtered at the lowest level. A certain depth below the water inlet level. The specific bay depth is given by the manufacturer. 3.2 Basic parameters | . The working range of the 3.2.2 series is shown in the figure. The specified point flow range is 0.57~11.38m/s, and the lift range is 10~24m. The inspection and deviation of the basic parameters listed in the table 3.2.3 are in accordance with the provisions of GB/T13008. . The Ministry of Mechanical and Electronic Industry approved the implementation on 1993-01-01 on 1992-07-20
600HL-10| |tt||600HL-12
600HL-16
600HL-24
700HL-10
700HL-12
700HL-16||tt ||700HL-24
900HL-10
900HL-12
900HL-16
900HL-24
1200HL-10
1200HL-12
1200HL-16
1200HL-24
1400HL-10
1400HL-12
1400HL-16
1400HL- 24
1600HL-10
1600HI-12
1600HL-16
1600HL-24
1800HL-10
1800HL-12| |tt||1800HL-16
1800HL-24
2000HL-10
2000HL-12
2000HL-16
2000HL-24||tt ||2200HL-10
2200HL-12
2200HL-24
2908||tt ||2052
14328| |tt||21960
22968||tt ||34344
Quantity
JB/T 643392
1. 04||tt ||1. 804
3. 47||tt ||2. 52
12| |tt||16
11.5| |tt||16.5
12.2| |tt||16.8
11.5||tt ||24
485||tt ||365
efficiency
85.6| |tt||86. 2
86. 4||tt ||87.1
87.3| |tt||87.7
Niu do
1200HL
1800HL
2400HL
1200HL
900H1-16||tt| |700HL16
JB/T 643392
2200HL
2000HL||tt ||1800HL~12
1600HL-32
1400HL12
3200HL12
900HL-12
factory
2200H,-10||tt ||20008L-10
1800HL-10
1690HL10
1400HD,10
1800FL-10
900HL-10
700HL- 10
600HL,-10
0||tt| |·3
e| |tt||eo
3.3 Model representation method
Model example:
JB/T6433-92||tt ||Nominal lift at specified point, m
Blade adjustment form: Semi-adjustable type is indicated by B, fully adjustable type is indicated by Q, fixed type is not indicated
Pressure water chamber type: volute type is indicated by W means, the guide vane type does not mean the inspection and disassembly type: the extractable type is expressed by C, the non-extractable type does not mean
vertical mixed flow pump
nominal diameter of the cumulative discharge outlet, mm
discharge Vertical mixed-flow pump with a nominal outlet diameter of 1800mm, non-extractable, vortex type, fully adjustable type, and a specified point lift of 16.8m: 1800HLWQ-16.
4 rotation directions
Pump rotation Direction, looking down from the driving end, the pump rotates in the clockwise direction of the membrane. Additional notes: www.bzxz.net
This standard is proposed and managed by Shenyang Water Pump Research Institute. This standard is drafted by Shanghai Water Pump Guang. The main drafters of this standard are Tang Lixing and Gu Yajian.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Implemented by the Ministry of Mechanical and Electronics Industry of the People's Republic of China on 1993-01-01
Released
Machinery Industry Standards of the People's Republic of China
Large and medium-sized vertical mixed-flow pumps
Types and basic parameters
1 Subject content and scope of application
This standard specifies the types of large and medium-sized vertical mixed-flow pumps (hereinafter referred to as "\ and basic parameters. JB/T643392
This standard is applicable to tickets for transporting clean water or other liquids with physical properties similar to water. The temperature of the transported liquid is not higher than 50C. 2 Reference Standards
GB/ T13008 mixed flow pump and axial flow pump technical conditions 3 types and basic parameters
3.1.1 According to the inspection and disassembly type, it is divided into:
Extractable type:
non-extractable,
3.1.2 Press water chamber types are divided into:
b.||tt ||Guide vane type:
Vortex type
According to the blade adjustment type:
b.| |tt||e.
Fixed type:
Rate adjustment type:
Fully adjustable type.
Inlet channel type
3.1.4| |tt||The pump inlet adopts a trumpet-shaped inlet channel. When the nominal diameter of the discharge port is greater than 1200mm, a square inlet channel can be used. 3.1.5 Minimum water inlet level
The pump inlet should be filtered at the lowest level. A certain depth below the water inlet level. The specific bay depth is given by the manufacturer. 3.2 Basic parameters | . The working range of the 3.2.2 series is shown in the figure. The specified point flow range is 0.57~11.38m/s, and the lift range is 10~24m. The inspection and deviation of the basic parameters listed in the table 3.2.3 are in accordance with the provisions of GB/T13008. . The Ministry of Mechanical and Electronic Industry approved the implementation on 1993-01-01 on 1992-07-20
600HL-10| |tt||600HL-12
600HL-16
600HL-24
700HL-10
700HL-12
700HL-16||tt ||700HL-24
900HL-10
900HL-12
900HL-16
900HL-24
1200HL-10
1200HL-12
1200HL-16
1200HL-24
1400HL-10
1400HL-12
1400HL-16
1400HL- 24
1600HL-10
1600HI-12
1600HL-16
1600HL-24
1800HL-10
1800HL-12| |tt||1800HL-16
1800HL-24
2000HL-10
2000HL-12
2000HL-16
2000HL-24||tt ||2200HL-10
2200HL-12
2200HL-24
2908||tt ||2052
14328| |tt||21960
22968||tt ||34344
Quantity
JB/T 643392
1. 04||tt ||1. 804
3. 47||tt ||2. 52
12| |tt||16
11.5| |tt||16.5
12.2| |tt||16.8
11.5||tt ||24
485||tt ||365
efficiency
85.6| |tt||86. 2
86. 4||tt ||87.1
87.3| |tt||87.7
Niu do
1200HL
1800HL
2400HL
1200HL
900H1-16||tt| |700HL16
JB/T 643392
2200HL
2000HL||tt ||1800HL~12
1600HL-32
1400HL12
3200HL12
900HL-12
factory
2200H,-10||tt ||20008L-10
1800HL-10
1690HL10
1400HD,10
1800FL-10
900HL-10
700HL- 10
600HL,-10
0||tt| |·3
e| |tt||eo
3.3 Model representation method
Model example:
JB/T6433-92||tt ||Nominal lift at specified point, m
Blade adjustment form: Semi-adjustable type is indicated by B, fully adjustable type is indicated by Q, fixed type is not indicated
Pressure water chamber type: volute type is indicated by W means, the guide vane type does not mean the inspection and disassembly type: the extractable type is expressed by C, the non-extractable type does not mean
vertical mixed flow pump
nominal diameter of the cumulative discharge outlet, mm
discharge Vertical mixed-flow pump with a nominal outlet diameter of 1800mm, non-extractable, vortex type, fully adjustable type, and a specified point lift of 16.8m: 1800HLWQ-16.
4 rotation directions
Pump rotation Direction, looking down from the driving end, the pump rotates in the clockwise direction of the membrane. Additional notes: www.bzxz.net
This standard is proposed and managed by Shenyang Water Pump Research Institute. This standard is drafted by Shanghai Water Pump Guang. The main drafters of this standard are Tang Lixing and Gu Yajian.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 8064.1-1996 Technical requirements for compression gas springs
- HG/T 2138-1991 Glass-lined concentric reducers
- JGJ 65-1989 Safety technical regulations for construction of hydraulic sliding formwork
- JB/T 7293-1994 Technical requirements for bolts and nuts for main bearing caps of internal combustion engines
- JB/T 9983-1999 Types and basic parameters of cylindrical trough motor vibrating feeder
- GB 15842-1995 Safety requirements and test methods for mobile communication equipment
- JB/T 7731.2-1995 Technical requirements for small gasoline engine direct-connected high-speed centrifugal pumps
- GBZ 22-2002 Diagnostic criteria for occupational melanosis
- JB 10146-1999 Safety requirements for cupolas and cupola charging machines
- JB/T 6312-1992 Mine flameproof coal drill transformer integrated equipment
- GB/T 21618-2008 Dangerous goods - Test method for burning rate of flammable solids
- GB/T 17002-1997 STANDARDization of production management for anti-counterfeiting printing products
- JB/T 4371.2-1999 Self-tightening drill chuck accuracy inspection
- GB/T 11318.12-1996 Cable distribution system equipment and components for television and sound signals Part 12: General specification for system output ports
- JB/T 9016.2-1999 Suspension conveyor sprocket
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com