NZS4512 2003 Fire Detection and Alarm Systems
建筑物中的火灾探测与报警系统
NZS4512 2003 Fire Detection and Alarm Systems
Fire Detection and Alarm Systems in Buildings
标准信息
STANDARD INFORMATION- 标准编号
- NZS4512 2003 Fire Detection and Alarm Systems
- 所属分类
- NZS 新西兰标准
- 发布机构
- Standards New Zealand
- 版本年份
- 2003
- 文件语言
- 英语
- 文件格式
- 文件页数
- 6 页
- 文件大小
- 1.12 MB
中文名称为参考译名,文件语言以原文为准。
· 更新:
标准简介
OVERVIEW中文简介
该标准规定了建筑物中火灾探测与报警系统的设计、构造、安装、调试和维护要求。它适用于多区域和单区域火灾报警系统,并涵盖探测器、手动报警按钮、警报装置、电源及系统失效时的预防措施。
English summary
This standard specifies requirements for the design, construction, installation, commissioning and maintenance of fire detection and alarm systems in buildings. It applies to multizone and single-zone fire alarm systems, including detectors, manual call points, alerting devices, power supplies and precautions when systems are inoperative.
以上为根据文件整理的内容简介。
相关标签
标准内容预览
DOCUMENT PREVIEWRELATED DOCUMENTS
Reference is made in this document to the following:
NEW ZEALAND STANDARDS
| NZS 4514:2002 | Interconnected smoke alarms for single household units |
| NZS 4515:xxxx | Fire sprinkler systems for residential occupancies (in preparation) |
| NZS 4541:xxxx | Automatic fire sprinkler systems (in preparation) |
| NZS 6401:2003 | Electric cables PVC insulated for working voltages up to and including 600/100 V |
| NZS 7702:1989 | Specification for colours for identification, coding and special purposes |
| NZS ISO/IEC 17025: 1999 | General requirements for the competence of testing and calibration laboratories |
JOINT AUSTRALIAN/ NEW ZEALAND STANDARDS
| AS/NZS 3000:2000 | Electrical installations (known as the Australian/ New Zealand Wiring Rules) |
| AS/NZS 3013:1995 | Electrical installations – Classification of the fire and mechanical performance of wiring systems |
| AS/NZS 3100:1997 | Approval and test specification – General requirements for electrical equipment |
| AS/NZS 4130:2001 | Polyethylene (PE) pipes for pressure applications |
| AS/NZS 5000:1999 | Electric cables – Polymeric insulated |
| AS/NZS ISO/IEC 17020: 2000 | General criteria for the operation of various types of bodies performing inspection |
INTERNATIONAL STANDARDS
| IEC 61000:- - - Part 4.3:2002 | Electromagnetic compatibility Testing and measurement technique – Radiated, radio-frequency, electromagnetic field immunity test |
AMERICAN STANDARDS
| ASTM B117-97 | Standard practice for operating salt spray (fog) apparatus |
6
COMMITTEE REPRESENTATION
This Standard was prepared by the Fire Alarms in Buildings Committee (P 4512) for the Standards Council established under the Standards Act 1988.
Standards New Zealand wishes to thank the following nominating organizations for their representation on Committee P 4512:
Building Industry Authority
Disabled Persons Assembly (New Zealand) Inc.
Electrical Contractors' Association of New Zealand Inc.
Fire Protection Association, New Zealand
Fire Protection Contractors' Association of New Zealand
Insurance Council of New Zealand
New Zealand Chapter of the Society of Fire Protection Engineers
New Zealand Fire Equipment Association Inc.
New Zealand Fire Service
New Zealand Institute of Architects Inc.
The Corporation of Insurance Brokers of New Zealand Inc.
The Institution of Fire Engineers
© COPYRIGHT
The copyright of this document is the property of the Standards Council. No part of it may be reproduced by photocopying or by any other means without the prior written permission of the Chief Executive of Standards New Zealand, unless the circumstances are covered by Part III of the Copyright Act 1994.
Standards New Zealand will vigorously defend the copyright in this Standard. Every person who breaches Standards New Zealand's copyright may be liable to a fine not exceeding $50,000 or to imprisonment for a term not to exceed three months. If there has been a flagrant breach of copyright, Standards New Zealand may also seek additional damages from the infringing party, in addition to obtaining injunctive relief and an account of profits.
Published by Standards New Zealand, the trading arm of the Standards Council, Private Bag 2439, Wellington 6020.
Telephone: (04) 498 5990, Fax: (04) 498 5994.
Website: www.standards.co.nz
| No | Date of issue | Description | Entered by, and date |
|---|---|---|---|
2
CONTENTS
| CONTENTS | PAGE |
|---|---|
| Committee representation | IFC |
| Copyright | IFC |
| Related documents | 4 |
| Foreword | 7 |
| Review of Standards | 7 |
| PART 1 GENERAL | |
| Section | |
| 101 Scope | 9 |
| 102 Objective | 9 |
| 103 Interpretation | 9 |
| 104 Definitions | 10 |
| 105 Declared functional requirements | 14 |
| 106 Types of fire alarms | 14 |
| 107 Compliance | 14 |
| 108 Legislative requirements | 15 |
| 109 Workmanship and competency | 16 |
| 110 Reliability | 16 |
| PART 2 DESIGN AND CONSTRUCTION – MULTIZONE FIRE ALARM SYSTEMS | |
| Section | |
| 201 Type and function | 17 |
| 202 Zones | 17 |
| 203 Ancillary services | 17 |
| 204 Fire alarm | 18 |
| 205 Silencing switches | 19 |
| 206 Manual reset facilities | 20 |
| 207 Evacuation and alert switches | 20 |
| 208 Defect warning | 20 |
| 209 Manual isolation from remote receiving centre | 21 |
| 210 Indicators and indicating units | 22 |
| 211 Electrical supply | 23 |
| 212 Battery charger | 24 |
| 213 Rechargeable batteries | 25 |
| 214 Non-rechargeable batteries | 25 |
| 215 Construction of control and indicating equipment | 26 |
| 216 Detection system | 27 |
| 217 Manual call points | 28 |
| 218 Alerting devices | 28 |
| 219 Addressable fire alarm systems | 30 |
| 220 Environmental tests | 30 |
| 221 Operational test | 33 |
| 222 Radiated radio frequency interference | 33 |
| 223 Marking | 33 |
| 224 Software controlled equipment | 33 |
Contents continued overleaf
3
PART 3 SINGLE ZONE FIRE ALARM SYSTEMS
Section
| 301 | Functions, limitations and components | 35 |
PART 4 INSTALLATION
Section
| 401 | Zones and sectors | 36 |
| 402 | Installation practice | 37 |
| 403 | Equipment location | 41 |
| 404 | Manual call point locations | 42 |
| 405 | Detector selection, location, position, spacing and coverage | 43 |
| 406 | Alerting devices | 52 |
| 407 | Multi-point aspirated smoke detectors | 53 |
| 408 | Delay timers | 55 |
| 409 | Owner isolation facilities | 55 |
PART 5 COMMISSIONING
Section
| 501 | General | 56 |
| 502 | Visual examination | 56 |
| 503 | Tests on electrical equipment | 57 |
| 504 | Tests to verify correct operation and function | 58 |
| 505 | Documents | 58 |
| 506 | Certificate of completion | 59 |
PART 6 MAINTAINING SYSTEMS IN COMPLIANCE AND GOOD WORKING ORDER
Section
| 601 | General | 60 |
| 602 | Monthly checks and tests | 60 |
| 603 | Annual checks and tests | 61 |
| 604 | Emergency warning and intercommunication systems (EWIS): additional requirements | 63 |
PART 7 PRECAUTIONS TO BE TAKEN WHEN A FIRE ALARM IS RENDERED INOPERATIVE
Section
| 701 | General | 64 |
| 702 | Notification | 64 |
| 703 | Permanent disconnection | 64 |
| 704 | Authorization | 64 |
Appendix
| A | Signalling to a remote receiving centre (Normative) | 65 |
| B | Types of fire alarms (Informative) | 69 |
| C | Supplementary detectors and systems (Informative) | 70 |
| D | Specification for heat actuated fire detectors (Normative) | 71 |
| E | Specification for manual call points (Normative) | 79 |
4
Contents
| F Audible altering signals (Normative) | 81 |
| G Standard zone index symbols (Normative) | 83 |
| H Selection and location of fire detectors (Informative) | 85 |
| J Certificate of completion for fire alarm system (Normative) | 89 |
| K Notification form – Fire alarm isolation (Normative) | 91 |
| L Other Standards for fire protection (Informative) | 93 |
Figure
| 1 Typical detector locations at apex of ceiling, roof or surface | 46 |
| 2 Effect of protrusions (beam, joist, purlin etc.) on detector location and spacing | 48 |
| 3 Protection of wardrobes and cupboards flowchart | 49 |
| A1 Example layout of zones and sectors | 67 |
| D1 Ball pressure apparatus | 74 |
| D2 Resistance to shock test | 74 |
| D3 Rate of rise heat-actuated fire detectors | 76 |
| E1 Notice to be displayed on, or adjacent to, each manual call point | 79 |
| F1 Evacuation signal | 81 |
| F2 Alert signal | 82 |
Table
| G1 Symbols | 83 |
| H1 Recommended fire detectors for different applications | 88 |
| Index | 94 |
5
RELATED DOCUMENTS
Reference is made in this document to the following:
NEW ZEALAND STANDARDS
| NZS 4514:2002 | Interconnected smoke alarms for single household units |
| NZS 4515:xxxx | Fire sprinkler systems for residential occupancies (in preparation) |
| NZS 4541:xxxx | Automatic fire sprinkler systems (in preparation) |
| NZS 6401:2003 | Electric cables PVC insulated for working voltages up to and including 600/100 V |
| NZS 7702:1989 | Specification for colours for identification, coding and special purposes |
| NZS ISO/IEC 17025: 1999 | General requirements for the competence of testing and calibration laboratories |
JOINT AUSTRALIAN/ NEW ZEALAND STANDARDS
| AS/NZS 3000:2000 | Electrical installations (known as the Australian/ New Zealand Wiring Rules) |
| AS/NZS 3013:1995 | Electrical installations – Classification of the fire and mechanical performance of wiring systems |
| AS/NZS 3100:1997 | Approval and test specification – General requirements for electrical equipment |
| AS/NZS 4130:2001 | Polyethylene (PE) pipes for pressure applications |
| AS/NZS 5000:1999 | Electric cables – Polymeric insulated |
| AS/NZS ISO/IEC 17020: 2000 | General criteria for the operation of various types of bodies performing inspection |
INTERNATIONAL STANDARDS
| IEC 61000:- - - Part 4.3:2002 | Electromagnetic compatibility Testing and measurement technique – Radiated, radio-frequency, electromagnetic field immunity test |
AMERICAN STANDARDS
| ASTM B117-97 | Standard practice for operating salt spray (fog) apparatus |
6
预览内容由文件识别整理,表格、公式及文字请以原始文件为准。
原文图片预览
PAGE IMAGES下载标准文件
NZS4512 2003 Fire Detection and Alarm Systems
英语 · PDF · 6 页 · 1.12 MB