Method for measurement of light transmissivity (τ546) for color pictrure tube glass panel
time:
2024-07-14 17:20:54
- SJ/T 10938-1996
- in force
Standard ID:
SJ/T 10938-1996
Standard Name:
Method for measurement of light transmissivity (τ546) for color pictrure tube glass panel
Chinese Name:
彩色显像管用屏玻璃光透射比(τ546)的测试方法
Standard category:
Electronic Industry Standard (SJ)
-
Date of Release:
1996-11-20 -
Date of Implementation:
1997-01-01
China Standard Classification Number:
General>>Standardization Management and General Provisions>>A01 Technical Management
alternative situation:
Original standard number GB 9474.3-88
Skip to download
Summary:
SJ/T 10938-1996 Test method for light transmittance (τ546) of screen glass for color picture tubes SJ/T10938-1996 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Method of measurement for light transmissivity(t546)of color pictrure tube glass panelGB9474.3—88
Reduced to SJ/T10938-96
This standard specifies the test method for glass light transmittance (t546), applicable to color picture tube screen glass. 1 Principle of the method
When light is incident vertically on a transparent object, the ratio of the luminous flux of the transmitted light to the incident light is the light transmittance of the object, and the measurement is carried out on a spectrophotometer. For color picture tube screen glass, the incident light with a wavelength of 546nm is specified, and the sample thickness is specified to be 10.16nm. 2 Instruments and Equipment
2.1 Grinder
2.2 Polisher
2.3 Micrometer
2.4 Spectrophotometer
3 Sample Preparation
Cut a sample of 30mm×40mm from the center of the screen. The sample should not have defects such as stones, bubbles and stripes, and be annealed. Grind and polish. The two surfaces of the sample are required to be parallel, and the thickness difference at each location should not exceed 0.02mm. The surface should be flat, smooth, transparent, and clean. It is used to measure the thickness with a micrometer. 4 Test Steps
Place the sample vertically in the optical path of the spectrophotometer, and measure the light transmittance of the sample to air at a wavelength of 546nm. 5 Calculation Results
Calculate the light transmittance at the specified thickness (10.16mm) according to the following formula. t, =+8c(1-r)* × 100%-
Wherein: %—light transmittance of the sample with specified thickness (10.16mm), %—light transmittance of the measured actual thickness, %;.-actual measured thickness, mm,
r—surface reflection coefficient【r
n-refractive index of the sample.
6Test Report
(n+1)2
Approved by the Ministry of Electronics Industry of the People's Republic of China on April 29, 1988TTKNTKAa
Implementation on December 1, 1988
The test report should include the following contents:
Light transmittance T846 (%);www.bzxz.net
Specified thickness of the sample is 10.16mm,
Actual thickness of the sample:
Instrument model.
Additional Notes:
GB9474.3-88
This standard was drafted by Factory 4400 of the Ministry of Electronics Industry and the Standards Research Institute.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Method of measurement for light transmissivity(t546)of color pictrure tube glass panelGB9474.3—88
Reduced to SJ/T10938-96
This standard specifies the test method for glass light transmittance (t546), applicable to color picture tube screen glass. 1 Principle of the method
When light is incident vertically on a transparent object, the ratio of the luminous flux of the transmitted light to the incident light is the light transmittance of the object, and the measurement is carried out on a spectrophotometer. For color picture tube screen glass, the incident light with a wavelength of 546nm is specified, and the sample thickness is specified to be 10.16nm. 2 Instruments and Equipment
2.1 Grinder
2.2 Polisher
2.3 Micrometer
2.4 Spectrophotometer
3 Sample Preparation
Cut a sample of 30mm×40mm from the center of the screen. The sample should not have defects such as stones, bubbles and stripes, and be annealed. Grind and polish. The two surfaces of the sample are required to be parallel, and the thickness difference at each location should not exceed 0.02mm. The surface should be flat, smooth, transparent, and clean. It is used to measure the thickness with a micrometer. 4 Test Steps
Place the sample vertically in the optical path of the spectrophotometer, and measure the light transmittance of the sample to air at a wavelength of 546nm. 5 Calculation Results
Calculate the light transmittance at the specified thickness (10.16mm) according to the following formula. t, =+8c(1-r)* × 100%-
Wherein: %—light transmittance of the sample with specified thickness (10.16mm), %—light transmittance of the measured actual thickness, %;.-actual measured thickness, mm,
r—surface reflection coefficient【r
n-refractive index of the sample.
6Test Report
(n+1)2
Approved by the Ministry of Electronics Industry of the People's Republic of China on April 29, 1988TTKNTKAa
Implementation on December 1, 1988
The test report should include the following contents:
Light transmittance T846 (%);www.bzxz.net
Specified thickness of the sample is 10.16mm,
Actual thickness of the sample:
Instrument model.
Additional Notes:
GB9474.3-88
This standard was drafted by Factory 4400 of the Ministry of Electronics Industry and the Standards Research Institute.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 50197-2000 Quality classification of 6MW~600MW steam turbine rotor and main shaft forgings
- GB/T 39315.6-2020 General resource of military and civilian—Data Model—Part 6:Facilities
- JB/T 3364.2-1999 Accuracy test of horizontal circular sawing machines
- GB/T 5527-1985 Determination of refractive index for inspection of vegetable oils and fats
- JB/T 8055-1996 Direct-fired lithium bromide absorption cooling and hot water units
- NY 525-2002 Organic Fertilizers
- GB 12624-1990 General technical requirements for labor protection gloves
- GB/T 3781.7-1993 Determination of iodine absorption value of acetylene black
- GB 12282.2-1990 Life test tables Simple linear unbiased estimation tables (extreme value distribution, Weibull distribution)
- GB/T 17850.11-2011 Preparation of steel substrates before application of paints and related products—Specifications for non-metallic blast-cleaning abrasives—Part 11:Special type grit of steel slag
- GB 4544-1996 Beer Bottle
- GB 12344-1990 Compilation specifications for 1:100000 topographic maps
- JB/T 9941-1999 Assembly complexity level of modular fixtures
- GB/T 27844-2011 Chemicals—Solution/extraction behaviour of polymers in water
- GB/T 5009.163-2003 Determination of multi-component residues of carbamate pesticides in animal foods by high performance liquid chromatography
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com