
GB/T 9104.5-1988 Test method for industrial stearic acid - Determination of freezing point
time:
2024-08-10 01:13:17
- GB/T 9104.5-1988
- Abolished
Standard ID:
GB/T 9104.5-1988
Standard Name:
Test method for industrial stearic acid - Determination of freezing point
Chinese Name:
工业硬脂酸试验方法 凝固点的测定
Standard category:
National Standard (GB)
-
Date of Release:
1988-04-30 -
Date of Implementation:
1988-10-01 -
Date of Expiration:
2008-12-01
Standard ICS number:
Chemical Technology>>Organic Chemistry>>71.080.40 Organic AcidChina Standard Classification Number:
Chemicals>>Organic Chemical Raw Materials>>G17 General Organic Chemical Raw Materials
alternative situation:
Replaced by GB/T 9104-2008Procurement status:
≈ISO 5466-80
Release date:
1988-04-30Review date:
2004-10-14Drafting Organization:
Daily Chemical Research Institute of the Ministry of Light IndustryFocal point Organization:
National Technical Committee on Standardization of Surfactants and DetergentsPublishing Department:
China Light Industry FederationCompetent Authority:
China Light Industry Federation

Skip to download
Summary:
GB/T 9104.5-1988 Test method for industrial stearic acid Determination of freezing point GB/T9104.5-1988 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Test methods for industrial stearic acids-Determination of titer
Subject content and scope of application
This standard specifies the method for determining the freezing point of industrial stearic acid. UDC 668.1.012
:543.06
GB9104.5—88
This standard applies to the determination of the freezing point of industrial stearic acid produced by hydrolysis of animal and vegetable fats by compression or distillation. 2 Definition
Freezing point: The highest temperature reached when stearic acid solidifies after being cooled to below the melting point according to the prescribed procedure. 3 InstrumentswwW.bzxz.Net
See Figure 1
1-Thermometer, 2-Precision thermometer, 3-Agitator: 4, 5.9--Cork (pad); 6-Water bath; 7-Coagulation tube; 8-Wide-mouth bottle; 10-Weight, 11-Beaker Approved by the Ministry of Light Industry of the People's Republic of China on April 30, 1988 and implemented on October 1, 1988
GB9104.5-88
3.1 Thermometer with a graduation of 0.1℃, 50~100℃, needs to be calibrated. 3.2 The diameter of the coagulation tube is about 25mm, the length is 100mm, and there is a scale about 57mm from the bottom. The tube mouth is equipped with a cork. The cork has two holes, the middle hole is inserted with a thermometer, and the other hole is inserted with a glass (or stainless steel) agitator. 3.3 Wide-mouth bottle 450mL, the inner diameter of the bottleneck is about 38mm, and the bottle mouth is equipped with a cork with a hole of 25mm in diameter. 3.4 Stirrer, glass or stainless steel, with the lower end bent into a ring with a diameter of 20 mm and perpendicular to the rod. 4 Test procedure
Melt the sample at about 30°C, so that its temperature should be at least 10°C higher than the freezing point. Place it in the freezing tube to the scale, insert the thermometer and stirrer, and make the mercury ball of the thermometer about 45mm below the scale. Place the freezing tube in a wide-mouth bottle with a cork, as shown in Figure 1. Keep the water bath temperature at about 30°C, use the stirrer on the thermometer to stir at a constant speed with an amplitude of about 40mm up and down (about 80~100 times per minute), and pay attention to the temperature. When the temperature stops falling for 30s, stop stirring immediately and carefully observe the sudden rise in temperature. 5 Processing of results
The highest temperature that rises is the freezing point of the sample. Take the average of the two tests as the final result. The allowable error of the results of two parallel tests is 0.2°C. Additional remarks:
This standard is proposed by the Ministry of Light Industry of the People's Republic of China. This standard is under the technical jurisdiction of the Daily Chemical Industry Research Institute of the Ministry of Light Industry. This standard was drafted by the Daily Chemical Industry Research Institute of the Ministry of Light Industry. This standard is equivalent to the determination of solidification point in Japanese Industrial Standard JIS K3331 "Industrial Stearic Acid Fatty Acid".
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Test methods for industrial stearic acids-Determination of titer
Subject content and scope of application
This standard specifies the method for determining the freezing point of industrial stearic acid. UDC 668.1.012
:543.06
GB9104.5—88
This standard applies to the determination of the freezing point of industrial stearic acid produced by hydrolysis of animal and vegetable fats by compression or distillation. 2 Definition
Freezing point: The highest temperature reached when stearic acid solidifies after being cooled to below the melting point according to the prescribed procedure. 3 InstrumentswwW.bzxz.Net
See Figure 1
1-Thermometer, 2-Precision thermometer, 3-Agitator: 4, 5.9--Cork (pad); 6-Water bath; 7-Coagulation tube; 8-Wide-mouth bottle; 10-Weight, 11-Beaker Approved by the Ministry of Light Industry of the People's Republic of China on April 30, 1988 and implemented on October 1, 1988
GB9104.5-88
3.1 Thermometer with a graduation of 0.1℃, 50~100℃, needs to be calibrated. 3.2 The diameter of the coagulation tube is about 25mm, the length is 100mm, and there is a scale about 57mm from the bottom. The tube mouth is equipped with a cork. The cork has two holes, the middle hole is inserted with a thermometer, and the other hole is inserted with a glass (or stainless steel) agitator. 3.3 Wide-mouth bottle 450mL, the inner diameter of the bottleneck is about 38mm, and the bottle mouth is equipped with a cork with a hole of 25mm in diameter. 3.4 Stirrer, glass or stainless steel, with the lower end bent into a ring with a diameter of 20 mm and perpendicular to the rod. 4 Test procedure
Melt the sample at about 30°C, so that its temperature should be at least 10°C higher than the freezing point. Place it in the freezing tube to the scale, insert the thermometer and stirrer, and make the mercury ball of the thermometer about 45mm below the scale. Place the freezing tube in a wide-mouth bottle with a cork, as shown in Figure 1. Keep the water bath temperature at about 30°C, use the stirrer on the thermometer to stir at a constant speed with an amplitude of about 40mm up and down (about 80~100 times per minute), and pay attention to the temperature. When the temperature stops falling for 30s, stop stirring immediately and carefully observe the sudden rise in temperature. 5 Processing of results
The highest temperature that rises is the freezing point of the sample. Take the average of the two tests as the final result. The allowable error of the results of two parallel tests is 0.2°C. Additional remarks:
This standard is proposed by the Ministry of Light Industry of the People's Republic of China. This standard is under the technical jurisdiction of the Daily Chemical Industry Research Institute of the Ministry of Light Industry. This standard was drafted by the Daily Chemical Industry Research Institute of the Ministry of Light Industry. This standard is equivalent to the determination of solidification point in Japanese Industrial Standard JIS K3331 "Industrial Stearic Acid Fatty Acid".
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 8012.2-1999 Machine tool fixture parts and components hook-shaped clamps (combination)
- JB/T 10399-2004 Off-grid wind turbine rotor blades
- GB 50258-1996 Electrical installation engineering 1kv and below wiring engineering construction and acceptance specification GB50258-96
- JB/T 8463-1996 Two-position four-way reversing valve 40MPa
- GB 19510.12-2005 Lamp controlgear Part 12: Particular requirements for miscellaneous electronic circuits used in conjunction with lamps
- GB/T 15940-1995 同步数字体系信号的基本复用结构
- GB/T 3454-1982 Definition table of interface circuits between data terminal equipment (DTE) and data circuit-terminating equipment (DCE)
- GB/T 14902-2003 Ready-mixed concrete
- GB/T 8622-1988 Determination of urease activity in soybean products
- GB/Z 18890.2-2002 Cross-linked polyethylene insulated power cables with rated voltage of 220 kV (Um=252 kV) and their accessories Part 2: Cross-linked polyethylene insulated power cables with rated voltage of 220 kV (Um=252 kV)
- JB/T 10053-1999 Water for lead-acid batteries
- CB 739-68 Portable Battery Light
- HG/T 20570.3-1995 Setting and selection of bursting discs
- HG/T 20701.14-2000 Equipment professional engineering design data management method
- JB/T 9839-1999 Technical requirements for cycloid rotary valve closed center hydrostatic steering gear
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com