HG/T 2138-1991 Glass-lined concentric reducers
time:
2024-08-13 11:00:45
- HG/T 2138-1991
- Abolished
Standard ID:
HG/T 2138-1991
Standard Name:
Glass-lined concentric reducers
Chinese Name:
搪玻璃同心异径管
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1991-08-19 -
Date of Implementation:
1992-01-01 -
Date of Expiration:
2009-07-01
Standard ICS number:
Chemical Technology>>Chemical Equipment>>71.120.99 Other Chemical EquipmentChina Standard Classification Number:
Chemical Industry>>Chemical Machinery and Equipment>>G94 Non-metallic Chemical Machinery and Equipment
alternative situation:
Replaces HG 5-259-1979; replaced by HG/T 2138-2009

Skip to download
Summary:
HG/T 2138-1991 Glass-lined concentric reducer HG/T2138-1991 Standard download decompression password: www.bzxz.net

Some standard content:
Chemical Industry Standard of the People's Republic of China
Glass concentric reducer
1 Subject content and scope of application
HG/T2138-91
This standard specifies the type, basic parameters, dimensions and technical requirements of glass concentric reducers. This standard is applicable to glass concentric reducers with a nominal pressure (PN) equal to or less than 1.0MPa and a medium temperature of -20℃ to 200℃ for type A reducers and -107 to 200℃ for type B and type C reducers. Reference standards
Tolerance and fit Limit deviation of dimensions without tolerance GB1804
Hexagon head bolts, grade C
GB57802
GB5782 Hexagon head bolts, grade A and B
GB6 1701 type hexagonal nut, A and B grade
GB9439 gray cast iron parts
ZBG94004. Technical conditions for glass equipment
HG/T2105 slip-on flanges for glass equipment
3 types, basic parameters and dimensions bzxz.net
3.1° slip-on flange connected steel glass concentric reducer (type A) according to the provisions of Figure 1 and Table 1,
Figure 1 Type A
*PN and DN in this standard represent pressure and nominal diameter respectively. Approved by the Ministry of Chemical Industry of the People's Republic of China on August 19, 1991. Standard Technology Network
All kinds of standards industry information free download
1992-01-01 implementation
Note: S in the figure and table refers to the front wall thickness of the glass. HG/T2138-91
32 Cast iron concentric glass reducer (type B) connected by slip-on flange shall comply with the provisions of Figure 2 and Table 2.
Far standard network, b product, ccm customer standard industry qualification bidding ticket PN
Reference weight, kg
PN/MPa
HG/T2138-91
Standard fee network
, cem various standard industry information free of charge category d
Reference weight, kg
PN/MPa
Note: S in the figure and table refers to the thickness of the front wall of the glass HG/T2138-91
3.3 Cast iron concentric glass reducer (type C) connected by flange shall comply with the provisions of Figure 3 and Table 3.
5 Various types of standard industry data are required below
Reference weight, kg
PN-0.6MPa
PN/MPa
HG/T2138—91
Note: S in the figure and table refers to the front wall thickness of the pond glass, D,
3.4 Marking example
Type A pond glass concentric reducer, PN is 0.6MPaDN, is 80mm, DN is 50mm, marking: concentric reducer PN0.6DN80/50-AHG/T2138—914 Technical requirements
4,1 Material selection, manufacturing, testing and acceptance shall be carried out in accordance with ZBG94004 and this standard. 4.2 Manufacturing tolerance and allowable deviation
Reference weight
4.2.1 The materials of Type B and Type C reducers shall comply with the relevant provisions of GB9439: 4.2.2 The allowable deviation of the center circle diameter of the bolt hole on the flange of Type C reducer and the chord length of two adjacent bolt holes is ±0.6mm. The allowable deviation of the chord length of any two bolt holes is +1mm.
Standard investment network.breo5o:com All kinds of standard industry information are free to download HG/T2138-91
4.2.3 The tolerance grade of the un-indicated tolerance size of the machined surface shall be IT14 as specified in GB1804, and the tolerance grade of the un-indicated tolerance size of the non-machined surface shall be IT16.
4.2.4 The allowable deviation of the length L of the reducer shall be as specified in Table 4. Table 4
65~100
125~200
4.3 The slip-on flanges for Type A and Type B reducers shall be selected in accordance with HG/T2105. 250
4.4 Bolts for flange connection: When PN is greater than 0.6MPa and less than or equal to 1.0MPa, follow the provisions of GB5782; when PN is less than or equal to 0.6MPa, follow the provisions of GB5780; nuts shall follow the provisions of GB6170; gaskets shall be selected according to relevant standards; 4.5 Water pressure test pressure and maximum working pressure at different temperatures shall be selected according to Table 5 Table 5
Packaging, transportation and storage
Test pressure
5.1 The product shall be accompanied by a packing list, product certificate and product instruction manual; 5.2 No collision shall be allowed during moving and transportation.
5.3 The exposed glass surface shall be sealed with soft gaskets and blind plates; 5.4 The product shall be stored indoors; open storage or stacking is not allowed; Additional instructions:
This standard is proposed by China National Chemical Equipment Corporation. This standard is under the jurisdiction of the National Sugar Glass Equipment Standardization Technical Committee. This standard was drafted by the Shanghai Pharmaceutical Design Institute of the State Drug Administration. The main drafters of this standard are Li Yijun, Hua Qiuyuan and Bao Aiyuan. MPa
Maximum working pressure P at the following temperature
200℃
From the date of implementation of this standard, the original standard HG5-259-79 "Tang Glass Concentric Reducer" issued by the Ministry of Chemical Industry of the People's Republic of China will be invalidated.
Standard Search Network sbsos:som
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Glass concentric reducer
1 Subject content and scope of application
HG/T2138-91
This standard specifies the type, basic parameters, dimensions and technical requirements of glass concentric reducers. This standard is applicable to glass concentric reducers with a nominal pressure (PN) equal to or less than 1.0MPa and a medium temperature of -20℃ to 200℃ for type A reducers and -107 to 200℃ for type B and type C reducers. Reference standards
Tolerance and fit Limit deviation of dimensions without tolerance GB1804
Hexagon head bolts, grade C
GB57802
GB5782 Hexagon head bolts, grade A and B
GB6 1701 type hexagonal nut, A and B grade
GB9439 gray cast iron parts
ZBG94004. Technical conditions for glass equipment
HG/T2105 slip-on flanges for glass equipment
3 types, basic parameters and dimensions bzxz.net
3.1° slip-on flange connected steel glass concentric reducer (type A) according to the provisions of Figure 1 and Table 1,
Figure 1 Type A
*PN and DN in this standard represent pressure and nominal diameter respectively. Approved by the Ministry of Chemical Industry of the People's Republic of China on August 19, 1991. Standard Technology Network
All kinds of standards industry information free download
1992-01-01 implementation
Note: S in the figure and table refers to the front wall thickness of the glass. HG/T2138-91
32 Cast iron concentric glass reducer (type B) connected by slip-on flange shall comply with the provisions of Figure 2 and Table 2.
Far standard network, b product, ccm customer standard industry qualification bidding ticket PN
Reference weight, kg
PN/MPa
HG/T2138-91
Standard fee network
, cem various standard industry information free of charge category d
Reference weight, kg
PN/MPa
Note: S in the figure and table refers to the thickness of the front wall of the glass HG/T2138-91
3.3 Cast iron concentric glass reducer (type C) connected by flange shall comply with the provisions of Figure 3 and Table 3.
5 Various types of standard industry data are required below
Reference weight, kg
PN-0.6MPa
PN/MPa
HG/T2138—91
Note: S in the figure and table refers to the front wall thickness of the pond glass, D,
3.4 Marking example
Type A pond glass concentric reducer, PN is 0.6MPaDN, is 80mm, DN is 50mm, marking: concentric reducer PN0.6DN80/50-AHG/T2138—914 Technical requirements
4,1 Material selection, manufacturing, testing and acceptance shall be carried out in accordance with ZBG94004 and this standard. 4.2 Manufacturing tolerance and allowable deviation
Reference weight
4.2.1 The materials of Type B and Type C reducers shall comply with the relevant provisions of GB9439: 4.2.2 The allowable deviation of the center circle diameter of the bolt hole on the flange of Type C reducer and the chord length of two adjacent bolt holes is ±0.6mm. The allowable deviation of the chord length of any two bolt holes is +1mm.
Standard investment network.breo5o:com All kinds of standard industry information are free to download HG/T2138-91
4.2.3 The tolerance grade of the un-indicated tolerance size of the machined surface shall be IT14 as specified in GB1804, and the tolerance grade of the un-indicated tolerance size of the non-machined surface shall be IT16.
4.2.4 The allowable deviation of the length L of the reducer shall be as specified in Table 4. Table 4
65~100
125~200
4.3 The slip-on flanges for Type A and Type B reducers shall be selected in accordance with HG/T2105. 250
4.4 Bolts for flange connection: When PN is greater than 0.6MPa and less than or equal to 1.0MPa, follow the provisions of GB5782; when PN is less than or equal to 0.6MPa, follow the provisions of GB5780; nuts shall follow the provisions of GB6170; gaskets shall be selected according to relevant standards; 4.5 Water pressure test pressure and maximum working pressure at different temperatures shall be selected according to Table 5 Table 5
Packaging, transportation and storage
Test pressure
5.1 The product shall be accompanied by a packing list, product certificate and product instruction manual; 5.2 No collision shall be allowed during moving and transportation.
5.3 The exposed glass surface shall be sealed with soft gaskets and blind plates; 5.4 The product shall be stored indoors; open storage or stacking is not allowed; Additional instructions:
This standard is proposed by China National Chemical Equipment Corporation. This standard is under the jurisdiction of the National Sugar Glass Equipment Standardization Technical Committee. This standard was drafted by the Shanghai Pharmaceutical Design Institute of the State Drug Administration. The main drafters of this standard are Li Yijun, Hua Qiuyuan and Bao Aiyuan. MPa
Maximum working pressure P at the following temperature
200℃
From the date of implementation of this standard, the original standard HG5-259-79 "Tang Glass Concentric Reducer" issued by the Ministry of Chemical Industry of the People's Republic of China will be invalidated.
Standard Search Network sbsos:som
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 3736.2-1983 Compression-type tapered thread long connector
- GB/T 39013-2020 Consumer Product Safety Risk Control Guide
- JB/T 2564-1991 Technical requirements for sliding bearing seats
- JB/T 5060-1991 Guidelines for the manufacture and use of process equipment
- JB/T 6377-1992 Pneumatic port connection thread types and dimensions
- MT 933-2005 Specifications for sports car protective devices
- GBZ 128-2002 Occupational external radiation personal monitoring specification
- HG 2958.7-1988 Determination of iron content in celestite ore Sulfosalicylic acid spectrophotometric method
- GB/T 5008.3-2005 Dimensions and markings of lead-acid starting battery terminals
- GB/T 2261.4-2003 Classificatoin and codes of basic personal information—Part 4:Codes for state of employment
- GB/Z 15629.1-2000 Information technology systems - Telecommunications and information exchange - Specific requirements for local area networks and metropolitan area networks - Part 1: Overview of local area network standards
- JB/T 6885-1993 Ventilator circular flange dimensions
- JB/T 7039-1993 Technical requirements for hydraulic vane pumps
- SB/T 10064-1992 Apple Sales Quality Standard
- HG/T 2694-1995 Positive PS Plate
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]