
JB/T 6213.3-1992 Flexible cables and cords for connecting motor windings Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
time:
2024-06-29 15:38:55
- JB/T 6213.3-1992
- Abolished
Standard ID:
JB/T 6213.3-1992
Standard Name:
Flexible cables and cords for connecting motor windings Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
Chinese Name:
电机绕组引接软电缆和软线 第3 部分 连续运行导体最高温度为90℃的软电缆和软线
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1992-06-16 -
Date of Implementation:
1993-01-01 -
Date of Expiration:
2007-07-01
China Standard Classification Number:
Electrical Engineering>>Electrical Materials and General Parts>>K13 Cables and Accessories
alternative situation:
Replaced by JB/T 6213.3-2006Procurement status:
BS 6195 NEQ AS-40007 NEQ
Focal point Organization:
Shanghai Cable Research InstitutePublishing Department:
Shanghai Cable Research Institute

Skip to download
Summary:
This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 90°C. This standard applies to flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 90°C. In addition to meeting the requirements specified in this standard, this standard shall also meet the relevant provisions of JB 6213.1. JB/T 6213.3-1992 Flexible cables and cords for connecting motor windings Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C JB/T6213.3-1992 Standard download decompression password: www.bzxz.net

Some standard content:
Mechanical Industry Standard of the People's Republic of China
JB/T 6213.3-1992
Flexible cables and cords for connecting motor windings
Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
Issued on June 16, 1992
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993
Mechanical Industry Standard of the People's Republic of China
Flexible cables and cords for connecting motor windings
Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
Subject content and scope of application
JB/T6213.31992
This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 90°C.
This standard applies to flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 90°C. In addition to meeting the requirements of this standard, the product shall also meet the relevant provisions of JB6213.1. 2
Cited standards
Application characteristics
Part 1 General provisions
Flexible cables and cords for connecting motor windings
The rated AC voltage of the cable (wire) is 500, 1000, 3000, 6000V, and the maximum continuous operating conductor temperature of the cable (wire) is 90°C. The allowable bending radius of the cable (wire) during laying should not be less than 4 times the outer diameter of the cable (wire). Model
The model of the cable (wire) product is as specified in Table 1. Table
Specifications are as specified in Table 2
Pin core EPDM rubber insulation Motor winding lead cable (wire) Copper core EPDM rubber insulation Oxycarbonized polyethylene sheath Motor winding lead cable (wire) Pin core EPDM rubber edge Fluoroether sheath Motor winding lead cable (wire) Pin core Fluorosulfonated polyethylene insulation Motor winding lead cable (wire) Approved by the Ministry of Machinery and Electronics Industry on June 16, 1992 and implemented on January 1, 1993
JB/T 6213.31992
Rated voltage
The structure of the cable (wire) is as specified in Table 3.
Nominal cross section
16~240
16~240
16~240
Test and inspection rules
The cable (wire) is tested according to the items specified in Table 4. Sequence
Structural dimensions
Conductor structure||tt| |Insulation thickness
Sheath thickness
Electrical properties
Conductor resistance
Power frequency voltage test
Bending test
Thermal effect test
Solvent resistance test
Impregnation paint resistance test
Additional instructions:
JB/T6213.31992
Article 5.2.1 of JB6213.1||tt| |Article 5.3.3 of JB6213.1 and the provisions of Table 3 of this standard. |Article 5.4.2 of JB6213.1 and the provisions of Table 3 of this standard.
Article 5.5.2 of JB6213.1 and the provisions of Table 1. |Article 5.5.3 of JB6213.1 and the provisions of Article 6.4. |Article 5.5.4 of JB6213.1 and the provisions of Article 6.5. |Article 5.5.5 of JB6213.1 and the provisions of Article 6.6. 6 Articles of JB6213.1 Articles 5.5.6 and 6.7 Articles of JB6213.1 Articles 5.5.7 and 6.8 This standard is proposed and managed by Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry and other units. The main drafters of this standard are Zhang Dihua and Lin Jingwen. Test type
Test method
GB4909
GB 2951. 4
Appendix A of JB6213.1
Appendix A of JB6213.1
Appendix A of JB6213.1
Appendix A of JB6213.1
People's Republic of China
Mechanical Industry Standard
Flexible cables and cords for connecting motor windings
Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
JB/T 6213.31992
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing
Postal Code: 100044)
Format: 880×12301/16
Number of words: XXX,XXXwwW.bzxz.Net
Sheets: x/X
Edition: X, XX, 19XX
Printing: X, XX, 19XX
Number of copies: 1-XXX
Price: XXX.XX Yuan
XX-XXX
Mechanical Industry Standards Service Network: http://www.JB.ac.cn669
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T 6213.3-1992
Flexible cables and cords for connecting motor windings
Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
Issued on June 16, 1992
Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993
Mechanical Industry Standard of the People's Republic of China
Flexible cables and cords for connecting motor windings
Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
Subject content and scope of application
JB/T6213.31992
This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 90°C.
This standard applies to flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 90°C. In addition to meeting the requirements of this standard, the product shall also meet the relevant provisions of JB6213.1. 2
Cited standards
Application characteristics
Part 1 General provisions
Flexible cables and cords for connecting motor windings
The rated AC voltage of the cable (wire) is 500, 1000, 3000, 6000V, and the maximum continuous operating conductor temperature of the cable (wire) is 90°C. The allowable bending radius of the cable (wire) during laying should not be less than 4 times the outer diameter of the cable (wire). Model
The model of the cable (wire) product is as specified in Table 1. Table
Specifications are as specified in Table 2
Pin core EPDM rubber insulation Motor winding lead cable (wire) Copper core EPDM rubber insulation Oxycarbonized polyethylene sheath Motor winding lead cable (wire) Pin core EPDM rubber edge Fluoroether sheath Motor winding lead cable (wire) Pin core Fluorosulfonated polyethylene insulation Motor winding lead cable (wire) Approved by the Ministry of Machinery and Electronics Industry on June 16, 1992 and implemented on January 1, 1993
JB/T 6213.31992
Rated voltage
The structure of the cable (wire) is as specified in Table 3.
Nominal cross section
16~240
16~240
16~240
Test and inspection rules
The cable (wire) is tested according to the items specified in Table 4. Sequence
Structural dimensions
Conductor structure||tt| |Insulation thickness
Sheath thickness
Electrical properties
Conductor resistance
Power frequency voltage test
Bending test
Thermal effect test
Solvent resistance test
Impregnation paint resistance test
Additional instructions:
JB/T6213.31992
Article 5.2.1 of JB6213.1||tt| |Article 5.3.3 of JB6213.1 and the provisions of Table 3 of this standard. |Article 5.4.2 of JB6213.1 and the provisions of Table 3 of this standard.
Article 5.5.2 of JB6213.1 and the provisions of Table 1. |Article 5.5.3 of JB6213.1 and the provisions of Article 6.4. |Article 5.5.4 of JB6213.1 and the provisions of Article 6.5. |Article 5.5.5 of JB6213.1 and the provisions of Article 6.6. 6 Articles of JB6213.1 Articles 5.5.6 and 6.7 Articles of JB6213.1 Articles 5.5.7 and 6.8 This standard is proposed and managed by Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry and other units. The main drafters of this standard are Zhang Dihua and Lin Jingwen. Test type
Test method
GB4909
GB 2951. 4
Appendix A of JB6213.1
Appendix A of JB6213.1
Appendix A of JB6213.1
Appendix A of JB6213.1
People's Republic of China
Mechanical Industry Standard
Flexible cables and cords for connecting motor windings
Part 3 Flexible cables and cords with a maximum continuous operating conductor temperature of 90°C
JB/T 6213.31992
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing
Postal Code: 100044)
Format: 880×12301/16
Number of words: XXX,XXXwwW.bzxz.Net
Sheets: x/X
Edition: X, XX, 19XX
Printing: X, XX, 19XX
Number of copies: 1-XXX
Price: XXX.XX Yuan
XX-XXX
Mechanical Industry Standards Service Network: http://www.JB.ac.cn669
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 1987-1986 Food additive citric acid
- JB/T 6307.1-1992 Test methods for power semiconductor modules - Rectifier arm pairs
- QB/T 2623.3-2003 Soap test method Determination of total alkali content and total fatty matter content in soap
- JB/T 10336-2002 Supplementary technical requirements for rolling bearings and their parts
- JB/T 9904.2-1999 Spline shaft grinding machine accuracy inspection
- JB/T 50093-1997 Rolling bearing life and reliability test evaluation method
- JB/T 7686-1995 Cone-disc ring-disc type continuously variable transmission
- GB/T 21619-2008 Dangerous goods - Test method for flammable solids which in contacting with water emit flammable gases
- HG/T 2129.29-1991 Acid-resistant phenolic plastic slip-on flanges for chemical equipment parts
- GB/T 28227.2-2011 Guidelines for the implementation of the quality management system of cultural service—Part 2:Indoor museum
- GB/T 7387-1999 Technical requirements for marine reference electrodes
- GB/T 5413.1-1997 Determination of protein in infant formula and milk powder
- JB/T 5997-1992 Technical requirements for brake systems of wheeled tractor trailer units
- GB 11701-1989 Basic provisions for marine gangways
- GB 4859-1984 Basic measurement methods for anti-interference characteristics of electrical equipment
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]