
GB 8808-1988 Peel test method for soft composite plastic materials
time:
2024-08-10 03:15:41
- GB 8808-1988
- in force
Standard ID:
GB 8808-1988
Standard Name:
Peel test method for soft composite plastic materials
Chinese Name:
软质复合塑料材料剥离试验方法
Standard category:
National Standard (GB)
-
Date of Release:
1988-02-13 -
Date of Implementation:
1988-07-01
Standard ICS number:
Rubber and plastics industry >> 83.080 PlasticsChina Standard Classification Number:
Light Industry, Cultural and Living Goods>>Daily Use Glass, Ceramics, Enamel, Plastic Products>>Y20 Daily Use Glass, Ceramics, Enamel, Plastic Products Comprehensive
Release date:
1988-02-13Review date:
2004-10-14Drafter:
Zeng Xinrong, Li DeyingDrafting Organization:
Plastics Processing Applied Science Research Institute, Ministry of Light IndustryFocal point Organization:
Plastics Processing Applied Science Research Institute, Ministry of Light IndustryProposing Organization:
Ministry of Light Industry of the People's Republic of ChinaPublishing Department:
Ministry of Light Industry of the People's Republic of ChinaCompetent Authority:
China Light Industry Federation

Skip to download
Summary:
This standard specifies the determination of the peeling force of various soft composite plastic materials on plastic or other substrates (such as aluminum foil, paper, fabric, etc.). GB 8808-1988 Peeling test method for soft composite plastic materials GB8808-1988 standard download decompression password: www.bzxz.net

Some standard content:
1 Subject Content
National Standard of the People's Republic of China
Test method for peel force of flexible laminated plastics
UDC 678.5/7.076
: 620.172
GB8808-88
This standard specifies the determination of peel force of various flexible laminated plastics laminated on plastic or other substrates (such as aluminum foil, paper, fabric, etc.).
2 Principle
Test the sample of specified width at a certain speed by T-peeling to determine the average peel force between the composite layer and the substrate. 3 Test Equipment
Tensile testing machine with graphic recording device, or other equipment that can meet the requirements of this test. 4 Test Specimen
4.1 Specimen sizewwW.bzxz.Net
Method A Width 15.0±0.1mm, length 200mm. Used for composite films, etc. Method B has a width of 30.0±0.2mm and a length of 150mm. It is used for artificial leather, woven composite bags, etc. 4.2 Sample preparation
Remove 50mm from both ends of the sample in the width direction, and evenly cut 5 longitudinal and transverse samples along the width direction of the sample. The composite direction is longitudinal.
Pre-peel the composite layer and the substrate 50mm along the length direction of the sample, and the peeled part shall not have obvious damage. If the sample is not easy to peel, immerse about 20mm of one end of the sample in an appropriate solvent for treatment, wait for the solvent to completely evaporate, and then conduct the peeling force test. If the composite layer cannot be separated from the substrate after this treatment, the test cannot be carried out. 5 State adjustment and test environment
The sample should be placed in an environment with a temperature of 23±2℃ and a relative humidity of 45%~55% for more than 4 hours, and then the test should be carried out in the above environment.
6 Test speed
Method A 300±50mm/min;
Method B 200±50mm/min.
7 Test steps
Clamp the two ends of the peeled part of the sample on the upper and lower clamps of the test machine respectively, so that the longitudinal axis of the peeled part of the sample coincides with the line connecting the center of the upper and lower clamps
GB8808-88
approved by the Ministry of Light Industry of the People's Republic of China on February 13, 1988 and implemented on July 1, 1988, and the tightness is appropriate. During the test, the unpeeled part is T-shaped with the tensile direction, as shown in Figure 1. Record the peeling force curve during the peeling process of the sample.
Figure 1 Schematic diagram of sample clamping
1-upper clamp; 2-lower clamp; 3-speeled part of the sample; 4-unpeeled sample 8 Representation of test results
According to the shape of the curve obtained in the test (refer to the three typical curves in Figure 2), adopt a value selection method that is close to them. Calculate the arithmetic mean of each group of samples, take two significant figures, and take Newton (N) as the unit. MW
Figure 2 Typical peeling force curve value
The dashed line indicates the average value of the sample
If necessary, calculate the standard deviation S as follows: S
Where: X, a single measured value;
——arithmetic mean of a group of measurements;
Number of measured values.
9Test report
The test report should include the following parts:
E(X, - X)2
Type and composite process of the sample tested;
State adjustment and test environment;
Sample width and test speed;
GB8808-88
Arithmetic mean of peeling force in longitudinal and transverse directions; If necessary, the standard deviation and maximum and minimum values of peeling force should be given; sampling date, test date, and test personnel. Additional remarks;
This standard is proposed by the Ministry of Light Industry of the People's Republic of China. This standard is under the jurisdiction of the Plastic Processing Applied Science Research Institute of the Ministry of Light Industry. This standard was drafted by the Plastic Processing Applied Science Research Institute of the Ministry of Light Industry. The main drafters of this standard are Zeng Xinrong and Li Deying. This standard refers to the Federal Republic of Germany national standard DIN53357-82 "Plastic tape and film test film peeling test".
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
Test method for peel force of flexible laminated plastics
UDC 678.5/7.076
: 620.172
GB8808-88
This standard specifies the determination of peel force of various flexible laminated plastics laminated on plastic or other substrates (such as aluminum foil, paper, fabric, etc.).
2 Principle
Test the sample of specified width at a certain speed by T-peeling to determine the average peel force between the composite layer and the substrate. 3 Test Equipment
Tensile testing machine with graphic recording device, or other equipment that can meet the requirements of this test. 4 Test Specimen
4.1 Specimen sizewwW.bzxz.Net
Method A Width 15.0±0.1mm, length 200mm. Used for composite films, etc. Method B has a width of 30.0±0.2mm and a length of 150mm. It is used for artificial leather, woven composite bags, etc. 4.2 Sample preparation
Remove 50mm from both ends of the sample in the width direction, and evenly cut 5 longitudinal and transverse samples along the width direction of the sample. The composite direction is longitudinal.
Pre-peel the composite layer and the substrate 50mm along the length direction of the sample, and the peeled part shall not have obvious damage. If the sample is not easy to peel, immerse about 20mm of one end of the sample in an appropriate solvent for treatment, wait for the solvent to completely evaporate, and then conduct the peeling force test. If the composite layer cannot be separated from the substrate after this treatment, the test cannot be carried out. 5 State adjustment and test environment
The sample should be placed in an environment with a temperature of 23±2℃ and a relative humidity of 45%~55% for more than 4 hours, and then the test should be carried out in the above environment.
6 Test speed
Method A 300±50mm/min;
Method B 200±50mm/min.
7 Test steps
Clamp the two ends of the peeled part of the sample on the upper and lower clamps of the test machine respectively, so that the longitudinal axis of the peeled part of the sample coincides with the line connecting the center of the upper and lower clamps
GB8808-88
approved by the Ministry of Light Industry of the People's Republic of China on February 13, 1988 and implemented on July 1, 1988, and the tightness is appropriate. During the test, the unpeeled part is T-shaped with the tensile direction, as shown in Figure 1. Record the peeling force curve during the peeling process of the sample.
Figure 1 Schematic diagram of sample clamping
1-upper clamp; 2-lower clamp; 3-speeled part of the sample; 4-unpeeled sample 8 Representation of test results
According to the shape of the curve obtained in the test (refer to the three typical curves in Figure 2), adopt a value selection method that is close to them. Calculate the arithmetic mean of each group of samples, take two significant figures, and take Newton (N) as the unit. MW
Figure 2 Typical peeling force curve value
The dashed line indicates the average value of the sample
If necessary, calculate the standard deviation S as follows: S
Where: X, a single measured value;
——arithmetic mean of a group of measurements;
Number of measured values.
9Test report
The test report should include the following parts:
E(X, - X)2
Type and composite process of the sample tested;
State adjustment and test environment;
Sample width and test speed;
GB8808-88
Arithmetic mean of peeling force in longitudinal and transverse directions; If necessary, the standard deviation and maximum and minimum values of peeling force should be given; sampling date, test date, and test personnel. Additional remarks;
This standard is proposed by the Ministry of Light Industry of the People's Republic of China. This standard is under the jurisdiction of the Plastic Processing Applied Science Research Institute of the Ministry of Light Industry. This standard was drafted by the Plastic Processing Applied Science Research Institute of the Ministry of Light Industry. The main drafters of this standard are Zeng Xinrong and Li Deying. This standard refers to the Federal Republic of Germany national standard DIN53357-82 "Plastic tape and film test film peeling test".
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- BB/T 0012-2008 Polyvinylidene chloride (PVDC) coated film
- GB/T 3756.2-1983 Compression fitting straight-through connector
- JB/T 5175-1991 Metallographic inspection of main parts of diesel engine fuel injection pump and injector assembly
- JB/T 6892-1993 Reciprocating piston oxygen compressor performance test method
- MT/T 789-1998 Diamond core drill bits for coal drilling
- GB/T 27836-2011 Test method for hazard classification of chemicals—External fire(bonfire) test
- GB 16916.1-1997 Residual current circuit breakers (RCCB) without overcurrent protection for household and similar purposes Part 1: General rules
- DB33/T 772-2009 Specification for after-sales service of furniture
- GB 18242-2000 Elastomer modified bitumen waterproofing membrane
- JB/T 6387-1992 Shaft-mounted arc cylindrical worm reducer
- JB/T 5240-1991 Technical requirements for paper filter elements for diesel engine diesel filters
- GB/T 5359.5-1996 Terminology for motorcycles and mopeds - Mass of two-wheeled vehicles
- HG/T 2620-1994 Color motion picture film sensitivity and average slope determination method
- JB/T 5678-1991 Technical requirements for fluidized bed tea drying machine
- JJG 845-2009 Raw Cotton Moisture Tester
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com