QB/T 1826-1993 Centrifugal sanitary pump
time:
2024-08-08 00:58:42
- QB/T 1826-1993
- in force
Standard ID:
QB/T 1826-1993
Standard Name:
Centrifugal sanitary pump
Chinese Name:
离心式卫生泵
Standard category:
Light Industry Standard (QB)
-
Date of Release:
1993-07-29 -
Date of Implementation:
1994-03-01
China Standard Classification Number:
Food>>Food Processing Machinery>>X99 Other Food Processing Machinery
alternative situation:
ZB/T Y99023-89
Drafter:
Guo Jianing, Zhou Minhua, Shen Xugen, Zhou LianfangDrafting Organization:
Ningbo Food Equipment Manufacturing FactoryFocal point Organization:
National Dairy Machinery Standardization CenterProposing Organization:
Technical Equipment Department of the Ministry of Light IndustryPublishing Department:
Ministry of Light Industry of the People's Republic of China
Skip to download
Summary:
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation, storage, etc. of centrifugal sanitary pumps. This standard applies to centrifugal sanitary pumps for transporting food fluid materials such as milk and dairy products (hereinafter referred to as "sanitary pumps"). QB/T 1826-1993 Centrifugal Sanitary Pumps QB/T1826-1993 Standard download decompression password: www.bzxz.net
Some standard content:
Light Industry Industry Standard of the People's Republic of China
Centrifugal Sanitary Pump
Subject Content and Scope of Application
QB/T1826--1993
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation, storage, etc. of centrifugal sanitary pumps.
This standard applies to centrifugal sanitary pumps (hereinafter referred to as "sanitary pumps") for conveying food fluid materials such as milk and dairy products. 2 Reference standardsWww.bzxZ.net
GB/T191 Packaging, storage and transportation pictorial signs
GB/T3216 Test methods for centrifugal pumps, mixed flow pumps, axial flow pumps and vortex pumps GB/T6388 Transport packaging and delivery marks
GB12073 Safety and sanitation of dairy equipment
JB/T8 Product labels
JB/T4127 Technical conditions for mechanical seals
QB/T842.8 General technical conditions for light industrial machinery weighing instruments Packaging QB/T1823 Method for compiling dairy machinery models ZBJ50004 Determination of noise sound pressure level of metal cutting machine tools 3 Product classification
3.1 Sanitary pumps are: single-stage, single-suction.
3.1.1 According to the impeller structure, they can be divided into: open, semi-open, and closed. 3.1.2 According to the sealing form, they can be divided into: single-end face and double-end face seals. 3.2 Model representation
Models are compiled in accordance with the provisions of QB/T1823 and in combination with product features. Y
3.3 Flow range: 1~120kL/h.
3.4 Head range, see Table 1.
Ministry of Light Industry of the People's Republic of China approved import on July 29, 1993
Closed
Semi-open
Nominal flow rate
Sanitary pump
One milk pump
One transport (delivery)
-Dairy machinery
Implemented on March 1, 1994
Head/m
Note: 1) It is a water column.
Technical requirements
QB/T1826—1993
Semi-open
4.1 Sanitary pumps shall be manufactured in accordance with the provisions of this standard and the drawings and technical documents approved by the prescribed procedures. 4.2 The temperature of the fluid material transported by the sanitary pump shall be lower than 80℃ and the viscosity shall be less than 1.4Pa·s. 4.3
Main parts materials shall comply with the provisions of GB12073. Closed
4.4 The welds in contact with the material shall be machined to remove slag, oxide scale and splash particles, and the surface roughness R. value shall not exceed 3.2μm. 4.5 The pump cavity shall be subjected to a water pressure test for sealing. No leakage shall be allowed within the prescribed test pressure time. 4.6 The impeller shall be statically balanced, and its static balance tolerance shall comply with the provisions of Table 2. The weight removal is at the edge of the blade. Table 2
Impeller outer diameter D/mm
Static balance tolerance on the maximum diameter of the impeller/gD≤180
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Centrifugal Sanitary Pump
Subject Content and Scope of Application
QB/T1826--1993
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation, storage, etc. of centrifugal sanitary pumps.
This standard applies to centrifugal sanitary pumps (hereinafter referred to as "sanitary pumps") for conveying food fluid materials such as milk and dairy products. 2 Reference standardsWww.bzxZ.net
GB/T191 Packaging, storage and transportation pictorial signs
GB/T3216 Test methods for centrifugal pumps, mixed flow pumps, axial flow pumps and vortex pumps GB/T6388 Transport packaging and delivery marks
GB12073 Safety and sanitation of dairy equipment
JB/T8 Product labels
JB/T4127 Technical conditions for mechanical seals
QB/T842.8 General technical conditions for light industrial machinery weighing instruments Packaging QB/T1823 Method for compiling dairy machinery models ZBJ50004 Determination of noise sound pressure level of metal cutting machine tools 3 Product classification
3.1 Sanitary pumps are: single-stage, single-suction.
3.1.1 According to the impeller structure, they can be divided into: open, semi-open, and closed. 3.1.2 According to the sealing form, they can be divided into: single-end face and double-end face seals. 3.2 Model representation
Models are compiled in accordance with the provisions of QB/T1823 and in combination with product features. Y
3.3 Flow range: 1~120kL/h.
3.4 Head range, see Table 1.
Ministry of Light Industry of the People's Republic of China approved import on July 29, 1993
Closed
Semi-open
Nominal flow rate
Sanitary pump
One milk pump
One transport (delivery)
-Dairy machinery
Implemented on March 1, 1994
Head/m
Note: 1) It is a water column.
Technical requirements
QB/T1826—1993
Semi-open
4.1 Sanitary pumps shall be manufactured in accordance with the provisions of this standard and the drawings and technical documents approved by the prescribed procedures. 4.2 The temperature of the fluid material transported by the sanitary pump shall be lower than 80℃ and the viscosity shall be less than 1.4Pa·s. 4.3
Main parts materials shall comply with the provisions of GB12073. Closed
4.4 The welds in contact with the material shall be machined to remove slag, oxide scale and splash particles, and the surface roughness R. value shall not exceed 3.2μm. 4.5 The pump cavity shall be subjected to a water pressure test for sealing. No leakage shall be allowed within the prescribed test pressure time. 4.6 The impeller shall be statically balanced, and its static balance tolerance shall comply with the provisions of Table 2. The weight removal is at the edge of the blade. Table 2
Impeller outer diameter D/mm
Static balance tolerance on the maximum diameter of the impeller/gD≤180
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 549-1996 Electric welded anchor chain
- HG/T 3510-2000 Emulsifier T-80
- CB/T 3708-1995 Technical requirements for repair of marine screw pumps
- GB 4333.1-1984 Chemical analysis methods for ferrosilicon - Determination of silicon content by gravimetric method with perchloric acid dehydration
- GB/T 33464-2016 Guide to the preparation and use of standard operating procedures for chemical analysis
- GB 16663-1996 Alcohol-based liquid fuels
- SY/T 5217-2000 Diamond drill bits and diamond core drill bits
- GBJ 93-1986 Industrial Automation Instrumentation Engineering Construction and Acceptance Specification GBJ93-86
- GB/T 3959-1994 Industrial anhydrous aluminum chloride
- GB/T 4248-2004 Technical requirements for hand-held 1:50 taper pin reamers
- JB/T 6662.1-1993 Types and basic parameters of light and small pipe water irrigation units
- GB/T 8885-1988 Edible corn starch
- JB/T 10299-2001 RH two-ring reducer
- JB/T 3712-1998 Small torsion spring comparator
- GB/T 12366.4-1991 Guideline for the work of complex standardization Drafting method for program of standard-complex
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com