GB 17053-1997 Hygienic standard for sodium carbonate in workshop air
time:
2024-08-06 03:23:54
- GB 17053-1997
- in force
Standard ID:
GB 17053-1997
Standard Name:
Hygienic standard for sodium carbonate in workshop air
Chinese Name:
车间空气中碳酸钠卫生标准
Standard category:
National Standard (GB)
-
Date of Release:
1997-01-01 -
Date of Implementation:
1998-01-02
Standard ICS number:
Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplaceChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
publishing house:
China Standards PressISBN:
155066.1-14631Publication date:
2004-07-29
Release date:
1997-11-11Review date:
2004-10-14Drafting Organization:
Dalian Institute of Occupational HygieneFocal point Organization:
Ministry of HealthPublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
Ministry of Health

Skip to download
Summary:
This standard specifies the maximum permissible concentration and time-weighted average permissible concentration of sodium carbonate in the air of workplaces and their monitoring and inspection methods. This standard is applicable to all types of enterprises that produce and use sodium carbonate. GB 17053-1997 Hygienic Standard for Sodium Carbonate in Workshop Air GB17053-1997 Standard download decompression password: www.bzxz.net

Some standard content:
GB17053-1997
This standard is formulated for the first time based on toxicological experiments, on-site labor hygiene surveys and epidemiological survey data, and with reference to foreign occupational exposure limits. It is a hygienic standard used for workplace environmental monitoring and health supervision. This standard shall be implemented from December 1, 1998. Appendix A of this standard is the appendix to the standard.
This standard is proposed and coordinated by the Ministry of Health.
This standard was drafted by Dalian Institute of Labor Hygiene, Harbin Medical University, and Dalian Chemical Industry Company. The main drafters of this standard are Ma Xiaohong, Wen Tao, Wang Ziyuan, Niu Qiong, and Yan Chengze. This standard is interpreted by the Chinese Academy of Preventive Medicine, the technical coordination unit entrusted by the Ministry of Health. 604
National Standard of the People's Republic of China
Hygienic standard for sodium carbonate in the air of workplace
GB17053—1997
This standard specifies the maximum allowable concentration and time-weighted average allowable concentration of sodium carbonate in the air of workplace and its monitoring and inspection methods. This standard is applicable to all types of enterprises that produce and use sodium carbonate. Hygienic requirements
The maximum allowable concentration of sodium carbonate in the air of workplace is 6mg/m3, and the time-weighted average allowable concentration is 3mg/m3. 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt the acid-base titration method, see Appendix A (Appendix to the standard). Approved by the State Administration of Technical Supervision on November 11, 1997 and implemented on December 1, 1998
A1 Principle
GB 17053—1997
Appendix A
(Appendix of Standard Recommendation)
Acid-base titration method for sodium carbonate in workshop air Sodium carbonate in the air is collected with perchloroethylene filter membrane, eluted with water, and titrated to the end point with methyl orange as indicator and hydrochloric acid standard solution, and the content of sodium carbonate is calculated.
A2 Instrument
Dust sampling clip or aluminum alloy sampling clip.
A2.2 Perchloroethylene filter membrane.
A2.3 Dust sampler, flow rate 0~30L/min. A2.4 Burette, 2mL.
Conical flask, 100mL.
A3 Reagents
A3.1 The water used in this method is distilled water. Hydrochloric acid standard solution 0.0100 mol/L. 1 mL of this solution is equivalent to (sodium carbonate) (Na2CO) 0.53 mg.
A3.2 Methyl orange solution 1 g/L.
A4 Sampling
Install the perchloroethylene filter membrane in the sampling clip and collect 200L of air at a flow rate of 25E/min. A5 Analysis steps
A5.1 Control test: Take the sampling clip with the filter membrane installed to the sampling point. Except for not collecting air, the rest of the operations are the same as the sample as the blank control of the sample.
A5.2 Sample treatment: Put the perchloroethylene filter membrane in a 50mL beaker, add 10mL of water and stir continuously for 10min to dissolve the sodium carbonate in the water; pour the solution into a conical flask, and wash the filter membrane and beaker twice with 10 mL of water, and pour the washing liquid into the conical flask together. A5.3 Determination: Add 1 drop of methyl orange indicator to the sample solution, carefully titrate with hydrochloric acid standard solution until orange just appears, and record the amount used. At the same time, take 20mL of water as a blank for titration. A6 Calculation
A6.1 Convert the sampling volume to the volume under standard conditions according to formula (A1). 273
+273+t
Where: Vo-
Convert to the sampling volume under standard conditions, L, V.-—The sampling volume when the atmospheric pressure is pkPa and the air temperature is t℃, L, p-—The atmospheric pressure at the sampling point, kPa;
The air temperature at the sampling point, ℃.
A6.2 Calculate the concentration of sodium carbonate in the air according to the following formula. (V - V2) × 0. 53 X 1 000bZxz.net
(A1)
Where: c—sodium carbonate concentration in air, mg/m3; GB17053—1997
V is the amount of hydrochloric acid standard solution used during sample titration, mL; V is the amount of hydrochloric acid standard solution used during blank titration, mLV. Convert to sampling volume under standard conditions, L. A7 Description
A7.1 The detection limit of this method is 42.4μg/20mL; the minimum detection concentration is 0.21mg/m3 (collecting 200L of air). When the sampling volume is 200L, the determination range of this method is 0.21~~50mg/m3. A7.2 The sampling efficiency of this method is 97.9%~100%; the elution efficiency is 95.4%~99.6%. 607
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This standard is formulated for the first time based on toxicological experiments, on-site labor hygiene surveys and epidemiological survey data, and with reference to foreign occupational exposure limits. It is a hygienic standard used for workplace environmental monitoring and health supervision. This standard shall be implemented from December 1, 1998. Appendix A of this standard is the appendix to the standard.
This standard is proposed and coordinated by the Ministry of Health.
This standard was drafted by Dalian Institute of Labor Hygiene, Harbin Medical University, and Dalian Chemical Industry Company. The main drafters of this standard are Ma Xiaohong, Wen Tao, Wang Ziyuan, Niu Qiong, and Yan Chengze. This standard is interpreted by the Chinese Academy of Preventive Medicine, the technical coordination unit entrusted by the Ministry of Health. 604
National Standard of the People's Republic of China
Hygienic standard for sodium carbonate in the air of workplace
GB17053—1997
This standard specifies the maximum allowable concentration and time-weighted average allowable concentration of sodium carbonate in the air of workplace and its monitoring and inspection methods. This standard is applicable to all types of enterprises that produce and use sodium carbonate. Hygienic requirements
The maximum allowable concentration of sodium carbonate in the air of workplace is 6mg/m3, and the time-weighted average allowable concentration is 3mg/m3. 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt the acid-base titration method, see Appendix A (Appendix to the standard). Approved by the State Administration of Technical Supervision on November 11, 1997 and implemented on December 1, 1998
A1 Principle
GB 17053—1997
Appendix A
(Appendix of Standard Recommendation)
Acid-base titration method for sodium carbonate in workshop air Sodium carbonate in the air is collected with perchloroethylene filter membrane, eluted with water, and titrated to the end point with methyl orange as indicator and hydrochloric acid standard solution, and the content of sodium carbonate is calculated.
A2 Instrument
Dust sampling clip or aluminum alloy sampling clip.
A2.2 Perchloroethylene filter membrane.
A2.3 Dust sampler, flow rate 0~30L/min. A2.4 Burette, 2mL.
Conical flask, 100mL.
A3 Reagents
A3.1 The water used in this method is distilled water. Hydrochloric acid standard solution 0.0100 mol/L. 1 mL of this solution is equivalent to (sodium carbonate) (Na2CO) 0.53 mg.
A3.2 Methyl orange solution 1 g/L.
A4 Sampling
Install the perchloroethylene filter membrane in the sampling clip and collect 200L of air at a flow rate of 25E/min. A5 Analysis steps
A5.1 Control test: Take the sampling clip with the filter membrane installed to the sampling point. Except for not collecting air, the rest of the operations are the same as the sample as the blank control of the sample.
A5.2 Sample treatment: Put the perchloroethylene filter membrane in a 50mL beaker, add 10mL of water and stir continuously for 10min to dissolve the sodium carbonate in the water; pour the solution into a conical flask, and wash the filter membrane and beaker twice with 10 mL of water, and pour the washing liquid into the conical flask together. A5.3 Determination: Add 1 drop of methyl orange indicator to the sample solution, carefully titrate with hydrochloric acid standard solution until orange just appears, and record the amount used. At the same time, take 20mL of water as a blank for titration. A6 Calculation
A6.1 Convert the sampling volume to the volume under standard conditions according to formula (A1). 273
+273+t
Where: Vo-
Convert to the sampling volume under standard conditions, L, V.-—The sampling volume when the atmospheric pressure is pkPa and the air temperature is t℃, L, p-—The atmospheric pressure at the sampling point, kPa;
The air temperature at the sampling point, ℃.
A6.2 Calculate the concentration of sodium carbonate in the air according to the following formula. (V - V2) × 0. 53 X 1 000bZxz.net
(A1)
Where: c—sodium carbonate concentration in air, mg/m3; GB17053—1997
V is the amount of hydrochloric acid standard solution used during sample titration, mL; V is the amount of hydrochloric acid standard solution used during blank titration, mLV. Convert to sampling volume under standard conditions, L. A7 Description
A7.1 The detection limit of this method is 42.4μg/20mL; the minimum detection concentration is 0.21mg/m3 (collecting 200L of air). When the sampling volume is 200L, the determination range of this method is 0.21~~50mg/m3. A7.2 The sampling efficiency of this method is 97.9%~100%; the elution efficiency is 95.4%~99.6%. 607
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG/T 3483-1978 Chemical reagent sodium tetraphenylborate (formerly HG/T 3-1164-78)
- JB/T 5303-2002 Supplementary structural dimensions of spherical ball bearings with seats
- GB/T 4549.11-2004 Railway rolling stock vocabulary Part 11: Special freight car accessories
- GB/T 3884.2-2000 Chemical analysis methods for copper concentrates - Determination of gold and silver content
- JB/T 8555-1997 Method of indicating heat treatment technical requirements on part drawings
- GB 13104-1991 Hygienic standard for white sugar
- JB/T 3411.70-1999 Dimensions of elastic clamping sleeves for straight shank tools
- JB/T 7288-1994 Basic parameters of drum type grass cutter series
- JB/T 53215-1999 Carbonated beverage filling and capping machines - Product quality classification
- GB/T 2855.7-1990 Narrow upper die seat with rear guide pin for die slide guide seat
- GB 16233-1996 Hygienic standard for acetic acid in workplace air
- GB 16272-1996 Safety technical requirements for wood processing circular saws
- GB 18824-2002 Product of designations of origin or geographical indication--Panjin rice
- GB/T 3421-1982 Sand mold centrifugal cast iron pipe
- HG/T 2186-1991 Tire water pressure test method
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]