Micrographics-Test object character and instruction for 16mm microfilm recorder
time:
2024-07-15 19:20:45
- GB/T 12356-1990
- Abolished
Standard ID:
GB/T 12356-1990
Standard Name:
Micrographics-Test object character and instruction for 16mm microfilm recorder
Chinese Name:
缩微摄影技术 16mm平台式缩微摄影机用测试标板的特征及其使用
Standard category:
National Standard (GB)
-
Date of Release:
1990-05-11 -
Date of Implementation:
1991-03-01 -
Date of Expiration:
2009-01-01
Standard ICS number:
Imaging Technology>>37.080 Document Imaging TechnologyChina Standard Classification Number:
General>>Economy, Culture>>A14 Library, Archives, Documentation and Information Work
alternative situation:
Replaced by GB/T 12356-2008
Release date:
1990-05-11Review date:
2004-10-14Drafting Organization:
National Microfilm Technical Standardization CommitteeFocal point Organization:
National Document Imaging Technology Standardization Technical CommitteePublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
National Standardization Administration

Skip to download
Summary:
This standard specifies the characteristics and use of test targets for 16mm flat-bed microfilm cameras. This standard applies to 105mm×mm microfilm cameras. This standard does not apply to COM microfilm cameras and rotary microfilm cameras. GB/T 12356-1990 Microfilming Technology Characteristics and Use of Test Targets for 16mm Flat-bed Microfilm Cameras GB/T12356-1990 Standard download decompression password: www.bzxz.net
This standard specifies the characteristics and use of test targets for 16mm flat-bed microfilm cameras. This standard applies to 105mm×mm microfilm cameras. This standard does not apply to COM microfilm cameras and rotary microfilm cameras.
This standard specifies the characteristics and use of test targets for 16mm flat-bed microfilm cameras. This standard applies to 105mm×mm microfilm cameras. This standard does not apply to COM microfilm cameras and rotary microfilm cameras.

Some standard content:
National Standard of the People's Republic of China
Micrographic Technology
Characteristics and Use of Test Target Plates for 16mm Platform Microfilm RecordersWww.bzxZ.net
Micrographles--Test object charaeter and instruction for 16 mmmicrofilm recorder
1 Subject content and scope of application
GB/T 12356-90
This standard specifies the characteristics and use of test targets for 16mm platform microfilm recorders. This standard is also applicable to 1n5mm×148mm microfilm recorders. This standard is not applicable to COM microfilm cameras and rotary microfilm cameras. 2 Reference standards
GB6161 Microfilming Technology No. 2 Test Pattern Characteristics and Its Application in Microfilming GB8987 Microfilming Technology Test Standard for Testing Optical Density of Negative Images in Microfilming 3 Test Standard
3.1 Bottom Plate Material
The bottom plate of the test standard plate shall be a white matte material with stable dimensions or a lead plate with a black surface, and the thickness shall be less than 2mm.
3.2 Plate Size
This standard plate is divided into two types: Plate A is 297mm×210mm, and Plate B is 297mm×420mm. 3.3 Shrinkage Test Ruler
The 10mm×100mm shrinkage test ruler at 35mm square to the center of the center test pattern array indicates the measurement unit in millimeters, with a character height of not less than 2mm, and is parallel to the bottom of the test standard plate. 3.4 Test pattern arrangement
Five No. 2 test patterns that meet the requirements of GB6161 are located at the center and four corners of the target plate as shown in the figure below. The array center of the No. 2 test pattern located in the center should be at the center of the test target plate, with a deviation error within 2 μm, and the edges of the test pattern parallel to the edges of the test target plate. The array center of the No. 2 test pattern located at the four corners should be on the diagonal of the target plate, 0.35 (d represents the length of the diagonal) from the center of the target plate, and the deviation error should be within 2m; the side of the test pattern is parallel to the diagonal: from the center of the test target plate, the numbers on the test pattern should be read clockwise,
State Administration of Technical Supervision 7990-06-11 approved 1991-03-01 practice
Note: I1R represents the reduction rate,
3.5 Reduction rate math card
GB/T12356
As shown in the figure, the black background white letter (equilinear font) card marked with 1:R is placed directly below the center test pattern. 55mm away from the center of the test pattern array, the height is not less than 15mm.
4 Usage
4.1A plate uses half-frame microfilm.
4.2B plate is used for full-frame microfilming.
4.3 When using the entry plate and B plate, the standard plate specified in GB8987 shall be used under the same conditions, and another frame shall be photographed. The determination of resolution shall be carried out in accordance with the method specified in GB 6161.
Additional remarks:
This standard was proposed by the National Technical Committee for Standardization of Microfilm Technology. This standard was drafted by the Fourth Technical Committee of the National Technical Committee for Standardization of Microfilm Technology. The main drafters of this standard are Zeng Jin and He Shaoxi.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Micrographic Technology
Characteristics and Use of Test Target Plates for 16mm Platform Microfilm RecordersWww.bzxZ.net
Micrographles--Test object charaeter and instruction for 16 mmmicrofilm recorder
1 Subject content and scope of application
GB/T 12356-90
This standard specifies the characteristics and use of test targets for 16mm platform microfilm recorders. This standard is also applicable to 1n5mm×148mm microfilm recorders. This standard is not applicable to COM microfilm cameras and rotary microfilm cameras. 2 Reference standards
GB6161 Microfilming Technology No. 2 Test Pattern Characteristics and Its Application in Microfilming GB8987 Microfilming Technology Test Standard for Testing Optical Density of Negative Images in Microfilming 3 Test Standard
3.1 Bottom Plate Material
The bottom plate of the test standard plate shall be a white matte material with stable dimensions or a lead plate with a black surface, and the thickness shall be less than 2mm.
3.2 Plate Size
This standard plate is divided into two types: Plate A is 297mm×210mm, and Plate B is 297mm×420mm. 3.3 Shrinkage Test Ruler
The 10mm×100mm shrinkage test ruler at 35mm square to the center of the center test pattern array indicates the measurement unit in millimeters, with a character height of not less than 2mm, and is parallel to the bottom of the test standard plate. 3.4 Test pattern arrangement
Five No. 2 test patterns that meet the requirements of GB6161 are located at the center and four corners of the target plate as shown in the figure below. The array center of the No. 2 test pattern located in the center should be at the center of the test target plate, with a deviation error within 2 μm, and the edges of the test pattern parallel to the edges of the test target plate. The array center of the No. 2 test pattern located at the four corners should be on the diagonal of the target plate, 0.35 (d represents the length of the diagonal) from the center of the target plate, and the deviation error should be within 2m; the side of the test pattern is parallel to the diagonal: from the center of the test target plate, the numbers on the test pattern should be read clockwise,
State Administration of Technical Supervision 7990-06-11 approved 1991-03-01 practice
Note: I1R represents the reduction rate,
3.5 Reduction rate math card
GB/T12356
As shown in the figure, the black background white letter (equilinear font) card marked with 1:R is placed directly below the center test pattern. 55mm away from the center of the test pattern array, the height is not less than 15mm.
4 Usage
4.1A plate uses half-frame microfilm.
4.2B plate is used for full-frame microfilming.
4.3 When using the entry plate and B plate, the standard plate specified in GB8987 shall be used under the same conditions, and another frame shall be photographed. The determination of resolution shall be carried out in accordance with the method specified in GB 6161.
Additional remarks:
This standard was proposed by the National Technical Committee for Standardization of Microfilm Technology. This standard was drafted by the Fourth Technical Committee of the National Technical Committee for Standardization of Microfilm Technology. The main drafters of this standard are Zeng Jin and He Shaoxi.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 6533-1997 Rotary vane vacuum pump
- GB/T 6565-2009 Classification and codes of occupations
- GB/T 5301-1985 Safe picture areas for motion-picture films for television-Positions and dimensions
- GB 18180-2000 Safe operation requirements for liquefied gas vessels
- GB 3074.1-1982 Determination of flexural strength of graphite electrodes
- HG 3623-1999 Trichlorfon TC
- GA/T 556.10-2007 The codes for finance security manage information-Part 10:The codes for certificate of financial security equipments
- GB/T 15555.5-1995 Determination of total chromium in solid wastes - Diphenylcarbazide spectrophotometric method
- QB/T 2212.5-1996 Construction tools (brick and tile) Trapezoidal flat trowel
- JB/T 5777.3-2002 Basic test methods for control and relay protection panels (cabinets and stations) used in secondary circuits of power systems
- QB/T 3781-1999 Test method for industrial casein
- JJG 531-1988 the DC Resistive Volt Radio Box
- GB 15989-1995 Diagnostic criteria and treatment principles for malaria
- GB/T 3453-1994 Basic control regulations for data communication
- SB/T 10524-2009 Purchase & sale practice for fresh and live prawns
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com