- Location:
- Standard Download >>
- National Standard (GB) >>
- GB 4844.2-1995 Pure helium

GB 4844.2-1995 Pure helium
time:
1995-12-20 16:00:00
- GB 4844.2-1995
- in force
Standard ID:
GB 4844.2-1995
Standard Name:
Pure helium
Chinese Name:
纯氦
Standard category:
National Standard (GB)
-
Date of Release:
1995-12-20 -
Date of Implementation:
1996-08-01
Standard ICS number:
Chemical Technology>>Chemical Products>>71.100.20 Industrial GasesChina Standard Classification Number:
Chemical Industry>>Other Chemical Products>>G86 Industrial Gases and Chemical Gases
alternative situation:
GB 4844-1984 GB 4845-1984
Release date:
1984-04-18Review date:
2004-10-14Drafting Organization:
Southwest Chemical Research Institute of the Ministry of Chemical IndustryFocal point Organization:
National Gas Standardization Technical CommitteePublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
China Petroleum and Chemical Industry Association

Skip to download
Summary:
This standard specifies the technical requirements, inspection methods, inspection rules for pure helium products, as well as product packaging, marking, storage, transportation, etc. This standard applies to bottled gaseous helium extracted from air, natural gas or factory exhaust gas by cryogenic method. It is mainly used for welding, diving breathing, special metal smelting, chromatographic analysis carrier gas, as well as pressurization and cleaning gas. GB 4844.2-1995 Pure helium GB4844.2-1995 standard download and decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Hydrogen
Pure helium
Subject content and scope of application
GB4844.2—1995
Replaced GB4844~4845·84
This standard specifies the technical requirements, inspection methods, inspection rules for pure nitrogen products, as well as product packaging, marking, storage, transportation, etc. This standard applies to bottled gaseous ammonia extracted from air, natural gas or factory exhaust gas by cryogenic method. It is mainly used for welding, diving breathing, special metal smelting, chromatographic analysis carrier gas, as well as pressurization and cleaning gas. Molecular formula: He
Relative molecular mass: 4.00260 (according to the 1991 international relative atomic mass). Reference standards
GB/T4844.1 Industrial hydrogen
GB/T4844.3 High purity nitrogen
GB/T5832.1 Determination of trace moisture in gas electrolysis Method GB/T8984 Determination of carbon monoxide, carbon dioxide and methane in gases Gas Chromatography 3 Technical requirements
The quality of pure nitrogen products should meet the requirements of Table 1. In the table, "Purity" and "Content" are both volume fractions (V/V). Table 1
Technical indicators
Nitrogen purity, 10~2
Chlorine content, 106
Hydrogen content, 106
Oxygen (argon) content, 10
Nitrogen content, 106
Oxide carbon content, 106| |tt||Carbon dioxide content, 10-6
Methane content, 106
Moisture content, 106
4 test methods
4.1 Hydrogen*Purity||tt ||National Technical Supervision Bureau approved high-quality products on December 20, 1995
refers to
standard
first-class product
Qualified product
99.99| |tt||40
1996-08-01 Implementation
GB 4844.2-1995
Hydrogen purity is expressed in volume fraction, calculated according to the following formula: = 100(Φ +++Φ+Φ++,+)×10-a where: Φ——Purity, 10-2(V/ V);
Φ - chlorine content (volume fraction), 10-6V/V) Φ2 - hydrogen content (volume fraction), 10-6 (V/V) @ - oxygen (argon) content ( Volume fraction), 10-6 (V/V); @----Nitrogen content (volume fraction), 10-6 (V/V); s—. Carbon monoxide content (volume fraction), 10-(V/V ); @ - carbon dioxide content (volume fraction) 10-6 (V/V); @, - methane content (volume fraction), 10-\ (V/V); Φg - moisture content (volume fraction), 10 - (V/V). 4.2 Determination of atmosphere, hydrogen, oxygen (argon), and nitrogen content 4.2.1 shall be carried out in accordance with Article 4.2 of GB/T4844.3. It is allowed to use an ammonia ionization detector, or Gas chromatographs with discharge detectors or photoionization detectors can directly inject samples for measurement and comply with the following regulations:
Ensure that the content of each component in the carrier gas used should be about one order of magnitude lower than that of the sample to be tested. a.
b. The operating parameters of the instrument are selected according to the instrument instructions to ensure that the detection limit of each component to be measured is about one order of magnitude lower than the value specified in Table 1.
ensures that the chromatographic column is suitable for each group. The separation of points is greater than 1. c
d. The standard mixed gas is prepared with nitrogen as the base gas, and the content of each component to be tested should be close to the values ??specified in Table 1, and it should have a standard sample certificate from the State Administration of Technical Supervision. serial number. bZxz.net
When the inspection results are inconsistent with Article 4.2.1 (concentration method), or there is objection to the product quality, the method specified in GB/T4844.3 Article 4.2 e.
shall be the arbitration method.
4.3 Determination of carbon monoxide, carbon dioxide, and methane content 4.3.1 Determination of carbon monoxide, carbon dioxide, and methane content shall be carried out in accordance with the regulations of GB/T8984. When the peak height of each tested component cannot guarantee three significant digits, the provisions of Article 4.3 in GB/T4844.3 shall be followed. 4.3.2 It is allowed to use a gas chromatograph with a nitrogen ionization detector (HID) or photoionization detector (PID) for direct sample injection and measurement. The content of carbon monoxide, carbon dioxide, and methane in the carrier gas used should be about one order of magnitude lower than that of the sample to be tested. Other operating conditions are selected according to the instrument instruction manual to ensure that the detection limit (volume fraction) of each component is approximately 0.2×10-(V/V), the separation of each component is greater than 1, and the relative deviation of two parallel measurements is not greater than 10%, and its average value is used as the measurement result. 4.4 Determination of moisture content
shall be carried out in accordance with the provisions of GB/T5832.1.
5 Inspection Rules
5.1 Pure ammonia products shall be inspected by the quality supervision and inspection department of the manufacturer in accordance with the provisions of this standard to ensure that the manufactured products meet the requirements of this standard. 5.2 Pure nitrogen products are inspected based on batch sampling. The batch size is the number of product bottles produced by one operation shift, or the number of product bottles per delivery. Samples submitted for inspection are randomly selected as specified in Table 2. 5.3 When any indicator of the unit (bottle) being inspected does not meet the requirements of this standard, the bottle product is unqualified. 5.4 When one bottle of the samples submitted for inspection fails, double samples from the same batch of products should be taken again according to Table 2 for re-inspection. If there are…- bottles that are unqualified, then the batch of products is unqualified. 5.5 Users have the right to inspect and accept products in accordance with the provisions of this standard. 5.6 When the supply and demand parties have objections to product quality, both parties shall negotiate for joint inspection and acceptance or submit to arbitration. 724
Product batch (bottle)
>50|| tt||6 Packaging, marking, storage and transportation
GB4844.2—1995
Table 2 Sampling table
Sampling quantity (bottles)
2||tt| |3
6.1 The packaging, marking, storage and transportation of pure nitrogen products shall comply with the provisions of Chapter 6 of GB/T4844.1. 6.2 Cylinders filled with nitrogen should be marked with "Pure Nitrogen" and should have a plastic cap on the bottle mouth when leaving the factory. Additional notes:
This standard is proposed by the Ministry of Chemical Industry of the People's Republic of China. This standard is under the jurisdiction of the Southwest Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard is drafted by the Southwest Chemical Research Institute of the Ministry of Chemical Industry and Weiyuan Natural Gas Chemical Plant of Sichuan Petroleum Administration Bureau. The main drafters of this standard are He Daoshan and Dai Qiwen. 725
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Hydrogen
Pure helium
Subject content and scope of application
GB4844.2—1995
Replaced GB4844~4845·84
This standard specifies the technical requirements, inspection methods, inspection rules for pure nitrogen products, as well as product packaging, marking, storage, transportation, etc. This standard applies to bottled gaseous ammonia extracted from air, natural gas or factory exhaust gas by cryogenic method. It is mainly used for welding, diving breathing, special metal smelting, chromatographic analysis carrier gas, as well as pressurization and cleaning gas. Molecular formula: He
Relative molecular mass: 4.00260 (according to the 1991 international relative atomic mass). Reference standards
GB/T4844.1 Industrial hydrogen
GB/T4844.3 High purity nitrogen
GB/T5832.1 Determination of trace moisture in gas electrolysis Method GB/T8984 Determination of carbon monoxide, carbon dioxide and methane in gases Gas Chromatography 3 Technical requirements
The quality of pure nitrogen products should meet the requirements of Table 1. In the table, "Purity" and "Content" are both volume fractions (V/V). Table 1
Technical indicators
Nitrogen purity, 10~2
Chlorine content, 106
Hydrogen content, 106
Oxygen (argon) content, 10
Nitrogen content, 106
Oxide carbon content, 106| |tt||Carbon dioxide content, 10-6
Methane content, 106
Moisture content, 106
4 test methods
4.1 Hydrogen*Purity||tt ||National Technical Supervision Bureau approved high-quality products on December 20, 1995
refers to
standard
first-class product
Qualified product
99.99| |tt||40
1996-08-01 Implementation
GB 4844.2-1995
Hydrogen purity is expressed in volume fraction, calculated according to the following formula: = 100(Φ +++Φ+Φ++,+)×10-a where: Φ——Purity, 10-2(V/ V);
Φ - chlorine content (volume fraction), 10-6V/V) Φ2 - hydrogen content (volume fraction), 10-6 (V/V) @ - oxygen (argon) content ( Volume fraction), 10-6 (V/V); @----Nitrogen content (volume fraction), 10-6 (V/V); s—. Carbon monoxide content (volume fraction), 10-(V/V ); @ - carbon dioxide content (volume fraction) 10-6 (V/V); @, - methane content (volume fraction), 10-\ (V/V); Φg - moisture content (volume fraction), 10 - (V/V). 4.2 Determination of atmosphere, hydrogen, oxygen (argon), and nitrogen content 4.2.1 shall be carried out in accordance with Article 4.2 of GB/T4844.3. It is allowed to use an ammonia ionization detector, or Gas chromatographs with discharge detectors or photoionization detectors can directly inject samples for measurement and comply with the following regulations:
Ensure that the content of each component in the carrier gas used should be about one order of magnitude lower than that of the sample to be tested. a.
b. The operating parameters of the instrument are selected according to the instrument instructions to ensure that the detection limit of each component to be measured is about one order of magnitude lower than the value specified in Table 1.
ensures that the chromatographic column is suitable for each group. The separation of points is greater than 1. c
d. The standard mixed gas is prepared with nitrogen as the base gas, and the content of each component to be tested should be close to the values ??specified in Table 1, and it should have a standard sample certificate from the State Administration of Technical Supervision. serial number. bZxz.net
When the inspection results are inconsistent with Article 4.2.1 (concentration method), or there is objection to the product quality, the method specified in GB/T4844.3 Article 4.2 e.
shall be the arbitration method.
4.3 Determination of carbon monoxide, carbon dioxide, and methane content 4.3.1 Determination of carbon monoxide, carbon dioxide, and methane content shall be carried out in accordance with the regulations of GB/T8984. When the peak height of each tested component cannot guarantee three significant digits, the provisions of Article 4.3 in GB/T4844.3 shall be followed. 4.3.2 It is allowed to use a gas chromatograph with a nitrogen ionization detector (HID) or photoionization detector (PID) for direct sample injection and measurement. The content of carbon monoxide, carbon dioxide, and methane in the carrier gas used should be about one order of magnitude lower than that of the sample to be tested. Other operating conditions are selected according to the instrument instruction manual to ensure that the detection limit (volume fraction) of each component is approximately 0.2×10-(V/V), the separation of each component is greater than 1, and the relative deviation of two parallel measurements is not greater than 10%, and its average value is used as the measurement result. 4.4 Determination of moisture content
shall be carried out in accordance with the provisions of GB/T5832.1.
5 Inspection Rules
5.1 Pure ammonia products shall be inspected by the quality supervision and inspection department of the manufacturer in accordance with the provisions of this standard to ensure that the manufactured products meet the requirements of this standard. 5.2 Pure nitrogen products are inspected based on batch sampling. The batch size is the number of product bottles produced by one operation shift, or the number of product bottles per delivery. Samples submitted for inspection are randomly selected as specified in Table 2. 5.3 When any indicator of the unit (bottle) being inspected does not meet the requirements of this standard, the bottle product is unqualified. 5.4 When one bottle of the samples submitted for inspection fails, double samples from the same batch of products should be taken again according to Table 2 for re-inspection. If there are…- bottles that are unqualified, then the batch of products is unqualified. 5.5 Users have the right to inspect and accept products in accordance with the provisions of this standard. 5.6 When the supply and demand parties have objections to product quality, both parties shall negotiate for joint inspection and acceptance or submit to arbitration. 724
Product batch (bottle)
>50|| tt||6 Packaging, marking, storage and transportation
GB4844.2—1995
Table 2 Sampling table
Sampling quantity (bottles)
2||tt| |3
6.1 The packaging, marking, storage and transportation of pure nitrogen products shall comply with the provisions of Chapter 6 of GB/T4844.1. 6.2 Cylinders filled with nitrogen should be marked with "Pure Nitrogen" and should have a plastic cap on the bottle mouth when leaving the factory. Additional notes:
This standard is proposed by the Ministry of Chemical Industry of the People's Republic of China. This standard is under the jurisdiction of the Southwest Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard is drafted by the Southwest Chemical Research Institute of the Ministry of Chemical Industry and Weiyuan Natural Gas Chemical Plant of Sichuan Petroleum Administration Bureau. The main drafters of this standard are He Daoshan and Dai Qiwen. 725
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- SY 4032.4-1993 Petroleum Construction Project Quality Inspection and Assessment Standard Communication Engineering (Long-distance Communication Open Line Carrier Telephone Installation Engineering)
- GB/T 15370-2004 General technical requirements for agricultural wheeled and crawler tractors
- QB/T 2745-2005 Cooking rice wine
- GB 8296-1987 Determination of manganese content in natural rubber latex (potassium periodate photometric method)
- GB/T 4960.5-1996 Terminology of nuclear science and technology Radiation protection and safety of radiation sources
- GB 12282.2-1990 Life test tables Simple linear unbiased estimation tables (extreme value distribution, Weibull distribution)
- QB/T 3691-1999 Box-type barley germination system
- JB/T 7733-1995 Technical requirements for small harvester
- JB/T 10358-2002 Water-cooled cables for industrial electric heating equipment
- JB/T 6324-1992 KE type 50A to 500A thyristors for electric welding machines
- GB/T 5329-1985 Test sieves and test sieving--Vocabulary
- HG/T 2968-1999 Industrial Sodium Pyrophosphate