GB 3074.2-1982 Determination method of elastic modulus of graphite electrode
time:
2024-08-11 10:38:06
- GB 3074.2-1982
- Abolished
Standard ID:
GB 3074.2-1982
Standard Name:
Determination method of elastic modulus of graphite electrode
Chinese Name:
石墨电极弹性模量测定方法
Standard category:
National Standard (GB)
-
Date of Release:
1982-05-10 -
Date of Implementation:
1983-03-01 -
Date of Expiration:
2008-11-01
Standard ICS number:
Electrical Engineering >> 29.040 Insulating FluidsChina Standard Classification Number:
Building Materials>>Carbon Materials>>Q51 Graphite Materials
alternative situation:
Replaced by GB/T 3074.2-2008
Release date:
1982-05-10Review date:
2004-10-14Drafter:
Poplar rootsDrafting Organization:
Shanghai Carbon FactoryFocal point Organization:
National Technical Committee on Steel StandardizationProposing Organization:
Ministry of Metallurgical Industry of the People's Republic of ChinaPublishing Department:
State Administration of StandardsCompetent Authority:
China Iron and Steel Association

Skip to download
Summary:
Elastic modulus is a measure of the relationship between stress and elongation or compression elastic deformation of a material under the action of external force. Its value is the ratio of normal stress to strain on the cross section of the specimen. GB 3074.2-1982 Determination of elastic modulus of graphite electrode GB3074.2-1982 standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Method for the determination of the elastic modulusof graphite electrodes
1 Definition
UDC 621.35.035.2
: 661.666.2
GB 3074.2-82
Elastic modulus is a measure of the relationship between stress and elongation or compression elastic deformation of a material under the action of an external force. Its value is the ratio of the normal stress to the strain on the cross section of the specimen.
2 Instruments and equipment
2.1 The device can be divided into five parts:wwW.bzxz.Net
Exciter - electrical/mechanical energy transducer, used to excite the resonance of the specimen. Receiver - mechanical/electrical energy transducer, used to receive the resonance signal of the specimen. Driving circuit - provides audio sinusoidal electrical signal. Detection circuit - amplifies and displays the electrical signal from the receiver. Sample holder - place the sample.
Drive circuit
Detection circuit
2.2Industrial balance: sensitivity 0.1g.
2.3Vernier caliper: measuring range 0~200mm, accuracy 0.02mm. 3Sample
Exciter
Sample"
Receiver!
3.1Size: For electrodes with a diameter greater than or equal to 300mm, the sample size is 20mm in diameter and 160mm in length. For electrodes with a diameter less than 300mm, the sample size is 10mm in diameter and 120mm in length. Processing accuracy is ±0.1mm. 3.2Requirements: Parallelism is not greater than 0.1mm/100mm, and smoothness is √6. There are no visible cracks or flaws on the sample surface. 3.3Sampling position: Take a piece of bad material parallel to the extrusion direction at the center of the end of the electrode to be tested and process it into a sample. 3.4 Quantity: Take 6 electrodes per furnace (two electrodes are taken from the middle and two ends of the furnace core). 4 Test steps
4.1 The sample must be baked in a drying oven at 110℃ for 2 hours and stored in a desiccator to cool to room temperature for use. 4.2 Measure the diameter, length and mass of the sample. Diameter measurement requires measuring three places along the axis of the sample, measuring each place twice, and the corresponding diameters of the two times are perpendicular to each other. Average the six measured data. Calculate the ratio of diameter to length, and determine the correction factor Cr according to this ratio. Issued by the General Administration of Standards of China on May 10, 1982
Implementation on March 1, 1983
GB 3074. 2-82
4.3 Turn on all instruments, preheat for 30 minutes, and use known stainless steel standards to identify whether the sensitivity and stability of the instruments are normal. 4.4 Carefully hang (place) the sample on the bracket, change the output frequency of the audio signal, make the sample resonate at the fundamental frequency, record the resonant frequency, then rotate the sample 90° around the axis and re-measure it, and take the average of the two measurements. 5 Calculation formula
The elastic modulus E (kg/cm2) of the sample is calculated as follows: accurate to one decimal place.
Where: E-elastic modulus, kg/cm2,
M mass, g
_-frequency, Hz,
~sample diameter, mm,
correction coefficient. Its value is shown in the table below.
6 Test report
The test report should include the following contents:
Sample number, specification and source.
Sample elastic modulus and its average value.
Additional instructions:
-X10-108
This standard is proposed by the Ministry of Metallurgical Industry of the People's Republic of China. This standard was drafted by Shanghai Carbon Factory and mainly drafted by Yang Shugen.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Method for the determination of the elastic modulusof graphite electrodes
1 Definition
UDC 621.35.035.2
: 661.666.2
GB 3074.2-82
Elastic modulus is a measure of the relationship between stress and elongation or compression elastic deformation of a material under the action of an external force. Its value is the ratio of the normal stress to the strain on the cross section of the specimen.
2 Instruments and equipment
2.1 The device can be divided into five parts:wwW.bzxz.Net
Exciter - electrical/mechanical energy transducer, used to excite the resonance of the specimen. Receiver - mechanical/electrical energy transducer, used to receive the resonance signal of the specimen. Driving circuit - provides audio sinusoidal electrical signal. Detection circuit - amplifies and displays the electrical signal from the receiver. Sample holder - place the sample.
Drive circuit
Detection circuit
2.2Industrial balance: sensitivity 0.1g.
2.3Vernier caliper: measuring range 0~200mm, accuracy 0.02mm. 3Sample
Exciter
Sample"
Receiver!
3.1Size: For electrodes with a diameter greater than or equal to 300mm, the sample size is 20mm in diameter and 160mm in length. For electrodes with a diameter less than 300mm, the sample size is 10mm in diameter and 120mm in length. Processing accuracy is ±0.1mm. 3.2Requirements: Parallelism is not greater than 0.1mm/100mm, and smoothness is √6. There are no visible cracks or flaws on the sample surface. 3.3Sampling position: Take a piece of bad material parallel to the extrusion direction at the center of the end of the electrode to be tested and process it into a sample. 3.4 Quantity: Take 6 electrodes per furnace (two electrodes are taken from the middle and two ends of the furnace core). 4 Test steps
4.1 The sample must be baked in a drying oven at 110℃ for 2 hours and stored in a desiccator to cool to room temperature for use. 4.2 Measure the diameter, length and mass of the sample. Diameter measurement requires measuring three places along the axis of the sample, measuring each place twice, and the corresponding diameters of the two times are perpendicular to each other. Average the six measured data. Calculate the ratio of diameter to length, and determine the correction factor Cr according to this ratio. Issued by the General Administration of Standards of China on May 10, 1982
Implementation on March 1, 1983
GB 3074. 2-82
4.3 Turn on all instruments, preheat for 30 minutes, and use known stainless steel standards to identify whether the sensitivity and stability of the instruments are normal. 4.4 Carefully hang (place) the sample on the bracket, change the output frequency of the audio signal, make the sample resonate at the fundamental frequency, record the resonant frequency, then rotate the sample 90° around the axis and re-measure it, and take the average of the two measurements. 5 Calculation formula
The elastic modulus E (kg/cm2) of the sample is calculated as follows: accurate to one decimal place.
Where: E-elastic modulus, kg/cm2,
M mass, g
_-frequency, Hz,
~sample diameter, mm,
correction coefficient. Its value is shown in the table below.
6 Test report
The test report should include the following contents:
Sample number, specification and source.
Sample elastic modulus and its average value.
Additional instructions:
-X10-108
This standard is proposed by the Ministry of Metallurgical Industry of the People's Republic of China. This standard was drafted by Shanghai Carbon Factory and mainly drafted by Yang Shugen.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 20206-2006 Technical specification of banking seal verification system
- GB/T 5009.21-2003 Determination of carbaryl residues in grains, oils and vegetables
- JB/T 7886.3-1999 Sawtooth cotton gin, sawtooth velvet stripping machine brush
- JB/T 3567-1999 High voltage insulator radio interference test method
- QB/T 2743-2005 Pickle Salt
- GB/T 5568-1994 Rubber and plastic hoses and hose assemblies - Hydraulic impulse test without flexure
- JB/T 9160.6-1999 Dimensions of double-ended toolholders for single-spindle turret automatic lathes
- HG/T 3506-1999 Determination of electrical conductivity of water or aqueous solution for surfactant testing
- JB/T 3411.118-1999 Dimensions of end milling cutter shanks with Morse taper shanks and end keys
- JB/T 5883.3-1991 电控设备图样及技术文件 格式
- GB/T 5070.1-2002 Chemical analysis methods for magnesia-chromium refractories Part 1: Gravimetric determination of loss on ignition
- GB/T 4312.1-1984 Technical parameters and measurement methods for FM broadcast transmitters - mono and stereo
- SJ 20620-1997 General Specification for Military Weather Radar
- GB/T 4323-2002 Elastic sleeve pin coupling
- GB/T 5009.97-2003 Determination of sodium cyclamate in foods
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com