GB/T 4517-1995 Test method for feeding direction stability of household sewing machines
time:
2024-08-05 08:30:40
- GB/T 4517-1995
- in force
Standard ID:
GB/T 4517-1995
Standard Name:
Test method for feeding direction stability of household sewing machines
Chinese Name:
家用缝纫机 送料方向稳定性测试方法
Standard category:
National Standard (GB)
-
Date of Release:
1995-05-02 -
Date of Implementation:
1995-12-01
Standard ICS number:
Clothing industry>>61.080 Sewing machines and other equipment for the clothing industryChina Standard Classification Number:
Light Industry, Cultural and Living Supplies>>Watches, Bicycles, Sewing Machines>>Y17 Sewing Machine
alternative situation:
GB 4517-1984Procurement status:
NEQ ISO 4817-1984
Release date:
1984-06-23Review date:
2004-10-14Drafter:
Fang Huangming, Guo MeizhuDrafting Organization:
Shanghai Sewing Machine Research InstituteFocal point Organization:
National Technical Committee for Standardization of Sewing MachineryProposing Organization:
China Light Industry FederationPublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
China Light Industry Federation

Skip to download
Summary:
This standard specifies the test materials and apparatus, test methods, presentation of test results and test reports for the feed direction stability test method of household sewing machines when sewing without threading. This standard applies to household sewing machines driven by electric motors, as well as household sewing machines driven by hand or foot. GB/T 4517-1995 Test method for feed direction stability of household sewing machines GB/T4517-1995 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Household sewing machines
Test method for feed direction stability
Household sewing machines
-Determination of directional stabilityGB/T4517-1995
Replaces GB4517-84
This standard adopts the international standard ISO 4817 "Test method for feed direction stability (deviation) of household sewing machines" in a non-equivalent manner. 1 Subject content and scope of application
This standard specifies the test materials and apparatus, test methods, expression of test results and test reports for the test method for feed direction stability of household sewing machines when sewing without threading. This standard applies to household sewing machines driven by electric motors, as well as household sewing machines driven by hand or foot. 2 Reference standards
GB406 Technical requirements for natural cotton fabrics
QB/T1514 Needles for household sewing machines
3 Test materials and apparatus
3.1 Test materials: 10 pieces of 130 medium plain cloth are cut into wrinkle-free test materials, which are 200mm long and 60mm wide. The long side must be along the warp direction, and a marking color line is drawn in the center of the test material, parallel to the long side of the test material. Note: Other test materials similar to the specified test materials are allowed, but they should be noted in the test report. 3.2 Needle: Nm80 needle as specified in QB/T1514. 3.3 Coordinate paper: No. 4 coordinate paper in millimeters, with a hole in the center to ensure that the feeding action of the feeding mechanism and the presser foot is not hindered. 3.4 Apparatus: Vernier caliper with an accuracy of 0.02mm. 4 Test methodWww.bzxZ.net
4.1 Test principle
Each sewing machine to be tested shall be tested five times. For household sewing machines capable of forming a zigzag seam, first test it five times with a straight seam, then adjust it to a zigzag seam and test it five more times. Calculate the average offset P for each. 4.2 Test conditions
4.2.1 Install the needle plate and presser foot supplied with the machine in accordance with the manufacturer's instructions for use corresponding to the seam. 4.2.2 Adjust the pressure of the presser foot in accordance with the manufacturer's instructions for use. a. If no specific value is specified in the instruction manual, and there is a presser foot pressure adjustment device for adjustment during use, the pressure when the presser foot is in the lowered position should be adjusted to 18±1N; b.
If there is no adjustment device, or if there is an adjustment device but it is not adjusted by the user, keep the original fixed value when the manufacturer ships. 4.2.3 Expand the working surface of the test sample so that the coordinate paper and the test sample must be placed completely flat on the working plane. The coordinate paper is fixed on the working plane with its longitudinal lines parallel to the theoretical feeding direction. 4.2.4 Adjust the stitch length to the following values;
a. Straight seam state: 1mm±0.1 mm; b. Z-shaped seam state: straight stitch length 0.5mm±0.05mm; horizontal stitch length 4mm±0.4mm.
4.2.5 Before each test, the needle must be replaced. 4.3 Test procedure
4.3.1 Place a single-layer test material on the coordinate paper between the feed member and the presser foot, and turn the upper wheel by hand to make the needle pierce the color line in the center of the test material. In the Z-shaped seam state, use the left side as the first needle to pierce the color line (see figure), make the long side of the test material parallel to the longitudinal line of the coordinate paper, and then put down the presser foot.
4.3.2 Feed the test material 150mm at a sewing speed of 700±35 stitches/min. If the sewing speed does not reach 700 stitches/min, test it according to the highest stable sewing speed that the sewing machine can achieve. Theoretical feeding direction
Operator-side
Marking color line
Sewing machine operation
Z-shaped seam test
Needle position at the end
No. 4 coordinate paper
Working surface
During the test, the operator is not allowed to touch the test material, and let it move forward naturally. 38
Z-shaped seam state
Actual direction
GB/T4517-1995
4.3.3 Use a vernier caliper to measure the vertical distance between the last needle hole of the machine needle piercing the test material and the color line. 5 Display of test results
5.1 Measure the result value A or B shown in the figure (error <±0.25mm), see the schematic diagram for details. 5.2 Measure the offset A...As or B.Bs obtained from 5 tests and calculate the arithmetic mean value P or PB6 Test report
The test report should include the following contents:
The number of this standard;
The model and number of the sewing machine under test;
The test speed of the sewing machine;
The specifications of the test material and the machine needle;
The test result value PA or PB under the straight seam state;
The test result value PA or P under the zigzag seam state;
The manufacturer's name
The test year, month and day,
The name of the tester.
Additional remarks:
This standard was proposed by the China Light Industry General Association.
This standard was drafted by the National Technical Committee for Sewing Machine Standardization and the Shanghai Sewing Machine Research Institute. The main drafters of this standard are Fang Yuming and Guo Meizhu. 39
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Household sewing machines
Test method for feed direction stability
Household sewing machines
-Determination of directional stabilityGB/T4517-1995
Replaces GB4517-84
This standard adopts the international standard ISO 4817 "Test method for feed direction stability (deviation) of household sewing machines" in a non-equivalent manner. 1 Subject content and scope of application
This standard specifies the test materials and apparatus, test methods, expression of test results and test reports for the test method for feed direction stability of household sewing machines when sewing without threading. This standard applies to household sewing machines driven by electric motors, as well as household sewing machines driven by hand or foot. 2 Reference standards
GB406 Technical requirements for natural cotton fabrics
QB/T1514 Needles for household sewing machines
3 Test materials and apparatus
3.1 Test materials: 10 pieces of 130 medium plain cloth are cut into wrinkle-free test materials, which are 200mm long and 60mm wide. The long side must be along the warp direction, and a marking color line is drawn in the center of the test material, parallel to the long side of the test material. Note: Other test materials similar to the specified test materials are allowed, but they should be noted in the test report. 3.2 Needle: Nm80 needle as specified in QB/T1514. 3.3 Coordinate paper: No. 4 coordinate paper in millimeters, with a hole in the center to ensure that the feeding action of the feeding mechanism and the presser foot is not hindered. 3.4 Apparatus: Vernier caliper with an accuracy of 0.02mm. 4 Test methodWww.bzxZ.net
4.1 Test principle
Each sewing machine to be tested shall be tested five times. For household sewing machines capable of forming a zigzag seam, first test it five times with a straight seam, then adjust it to a zigzag seam and test it five more times. Calculate the average offset P for each. 4.2 Test conditions
4.2.1 Install the needle plate and presser foot supplied with the machine in accordance with the manufacturer's instructions for use corresponding to the seam. 4.2.2 Adjust the pressure of the presser foot in accordance with the manufacturer's instructions for use. a. If no specific value is specified in the instruction manual, and there is a presser foot pressure adjustment device for adjustment during use, the pressure when the presser foot is in the lowered position should be adjusted to 18±1N; b.
If there is no adjustment device, or if there is an adjustment device but it is not adjusted by the user, keep the original fixed value when the manufacturer ships. 4.2.3 Expand the working surface of the test sample so that the coordinate paper and the test sample must be placed completely flat on the working plane. The coordinate paper is fixed on the working plane with its longitudinal lines parallel to the theoretical feeding direction. 4.2.4 Adjust the stitch length to the following values;
a. Straight seam state: 1mm±0.1 mm; b. Z-shaped seam state: straight stitch length 0.5mm±0.05mm; horizontal stitch length 4mm±0.4mm.
4.2.5 Before each test, the needle must be replaced. 4.3 Test procedure
4.3.1 Place a single-layer test material on the coordinate paper between the feed member and the presser foot, and turn the upper wheel by hand to make the needle pierce the color line in the center of the test material. In the Z-shaped seam state, use the left side as the first needle to pierce the color line (see figure), make the long side of the test material parallel to the longitudinal line of the coordinate paper, and then put down the presser foot.
4.3.2 Feed the test material 150mm at a sewing speed of 700±35 stitches/min. If the sewing speed does not reach 700 stitches/min, test it according to the highest stable sewing speed that the sewing machine can achieve. Theoretical feeding direction
Operator-side
Marking color line
Sewing machine operation
Z-shaped seam test
Needle position at the end
No. 4 coordinate paper
Working surface
During the test, the operator is not allowed to touch the test material, and let it move forward naturally. 38
Z-shaped seam state
Actual direction
GB/T4517-1995
4.3.3 Use a vernier caliper to measure the vertical distance between the last needle hole of the machine needle piercing the test material and the color line. 5 Display of test results
5.1 Measure the result value A or B shown in the figure (error <±0.25mm), see the schematic diagram for details. 5.2 Measure the offset A...As or B.Bs obtained from 5 tests and calculate the arithmetic mean value P or PB6 Test report
The test report should include the following contents:
The number of this standard;
The model and number of the sewing machine under test;
The test speed of the sewing machine;
The specifications of the test material and the machine needle;
The test result value PA or PB under the straight seam state;
The test result value PA or P under the zigzag seam state;
The manufacturer's name
The test year, month and day,
The name of the tester.
Additional remarks:
This standard was proposed by the China Light Industry General Association.
This standard was drafted by the National Technical Committee for Sewing Machine Standardization and the Shanghai Sewing Machine Research Institute. The main drafters of this standard are Fang Yuming and Guo Meizhu. 39
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 4703-2001 Capacitor voltage transformer
- HG/T 3697-2002 Hot melt adhesives for textiles
- GB/T 9115.1-2000 Flat and raised face welding steel pipe flanges
- GB/T 4499-1997 Determination of antioxidants in vulcanized rubber - Thin layer chromatography
- JB/T 7266-1994 Volumetric vacuum pump performance measurement method
- JB/T 8545-1997 Escalator step chains, accessories and sprockets
- HG/T 2058.1-1991 Glass-lined thermometer sleeve
- GBZ 101-2002 Diagnostic criteria for radiation-induced thyroid disease
- JB/T 1296.2-1999 Technical requirements for combined punching and shearing machines
- GB/T 3532-1995 Daily-use porcelain
- JB/T 5000.14-1998 General technical conditions for heavy machinery non-destructive testing of steel castings
- GB/T 8573-1999 Determination of available phosphorus content in compound fertilizers
- GB/T 38935-2020 On-orbit radiometric characteristics assessment foroptical imaging remote sensor—VIS-SWIR
- QB/T 3628-1999 Polytetrafluoroethylene raw tape for thread sealing
- GB/T 31565-2015 Vitreous ang porcelain enamels—Determination of the edge covering on enamelled steel plate to be used in heat exchangers
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com