GB/T 4372.3-2001 Direct chemical analysis of zinc oxide - Determination of copper oxide content by atomic absorption spectrometry
time:
2024-08-04 11:37:09
- GB/T 4372.3-2001
- in force
Standard ID:
GB/T 4372.3-2001
Standard Name:
Direct chemical analysis of zinc oxide - Determination of copper oxide content by atomic absorption spectrometry
Chinese Name:
直接法氧化锌化学分析方法 原子吸收光谱法测定氧化铜量
Standard category:
National Standard (GB)
-
Date of Release:
2001-07-01 -
Date of Implementation:
2001-12-01
Standard ICS number:
Metallurgy>>Non-ferrous metals>>77.120.60 Lead, zinc, tin and their alloysChina Standard Classification Number:
Metallurgy>>Metal Chemical Analysis Methods>>H13 Heavy Metals and Their Alloys Analysis Methods
alternative situation:
GB/T 4372.3-1984
Release date:
1984-04-30Review date:
2004-10-14Drafter:
Kuang Haiyan, Yao Xiaohong, Mao Yanling, Tan PingshengDrafting Organization:
Hunan Shuikoushan Mining BureauFocal point Organization:
National Technical Committee for Standardization of Nonferrous MetalsProposing Organization:
China Nonferrous Metals Industry AssociationPublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaCompetent Authority:
China Nonferrous Metals Industry Association

Skip to download
Summary:
This standard specifies the determination method of copper oxide content in direct zinc oxide. This standard is applicable to the determination of copper oxide content in direct zinc oxide. Determination range: 0.0005~0.010%. GB/T 4372.3-2001 Chemical analysis method of direct zinc oxide Determination of copper oxide content by atomic absorption spectrometry GB/T4372.3-2001 Standard download decompression password: www.bzxz.net

Some standard content:
GB/T4372.3--2001
This standard is a revision of GB/T4372.3-1984 "Zinc Oxide (Direct Method) Chemical Analysis Method Bicyclohexanone Oxalate Photometric Determination of Copper Oxide Content". The main content of the revision is the determination of copper oxide content by atomic absorption spectrometry. This standard complies with:
GB/T1467-1978 General Principles and General Provisions of Metallurgical Product Chemical Analysis Method Standard GB/T7728--1987 General Principles of Flame Atomic Absorption Spectrometry for Chemical Analysis of Metallurgical Products GB/T17433-1998 Basic Terminology for Chemical Analysis of Metallurgical Products This standard will replace GB/T4372.3-1984 from the date of implementation. Appendix A of this standard is a reminder appendix. This standard is proposed by China Nonferrous Metals Industry Association. This standard is under the jurisdiction of China Nonferrous Metals Industry Standard Metrology and Quality Research Institute. This standard is drafted by Shuikoushan Mining Bureau. The main drafters of this standard are Kuang Haiyan, Yao Xiaohong, Mao Yanling and Tan Husheng. The National Technical Committee for Standardization of Nonferrous Metals is entrusted with the interpretation of this standard. 119
1 Scope
National Standard of the People's Republic of China
Chemical analysis method of zinc oxide produced by direct process
Determination of copper oxide content by atomic absorption spectrometry
Methods for chemical analysis of zinc oxide produced by direct process- Determination of copper oxide content---Atomic absorption spectrometry method This standard specifies the method for determining the copper oxide content in zinc oxide produced by direct process. GB/T 4372.3-2001
Replaces GB/T 4372.3-1984
This standard is applicable to the determination of copper oxide content in zinc oxide produced by direct process. Determination range: 0.0005% to 0.010%. 2 Method Summary
The sample is dissolved in nitric acid. In a dilute nitric acid (5+95 medium, an air-acetylene flame is used to measure the absorbance of copper at a wavelength of 324.8nm on an atomic absorption spectrometer. The content of copper oxide is calculated using the standard curve method. 3 Reagents
3.1 Nitric acid (1+1).
3.2 Copper standard stock solution: Weigh 0.1000g of pure copper (99.99%) in a 300mL beaker, add 10mL of nitric acid (3.1), heat at low temperature to dissolve, boil to drive off nitrogen oxides, cool, transfer to a 1000mL volumetric flask, dilute to the mark with water, and mix. This solution contains 0.1 mg in 1ml. Copper.
3.3 Copper standard solution: Pipette 10.00mL of copper standard storage solution (3.2) into a 100mL volumetric flask, add 5mL of nitric acid (3.1), dilute to scale with water, and mix. This solution contains 10μg of copper in 1mL. 4 Instruments
Atomic absorption spectrometer with copper hollow cathode lamp. Under the best working conditions of the instrument, any instrument that can meet the following indicators can be used. Sensitivity: In a solution consistent with the matrix of the sample solution to be measured, the characteristic concentration of copper should not exceed 10μg. Greater than 0.035μg/mL. Precision: When the absorbance is measured 10 times with the highest concentration standard solution, the standard deviation should not exceed 1.0% of the average absorbance; when the absorbance is measured 10 times with the lowest concentration standard solution (not the zero standard solution), the standard deviation should not exceed 0.5% of the average absorbance of the highest concentration standard solution.
Linearity of working curve: Divide the working curve into five sections according to concentration. The ratio of the absorbance difference of the highest section to the absorbance difference of the lowest section should not be less than 0. 7.
For instrument working conditions, see Appendix A (indicative appendix). Approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on July 10, 2001 120
Implemented on December 1, 2001
5 Analysis steps
Weigh the sample according to Table 1, accurate to 0.0001g. Mass fraction of iron oxide, %
0. 000 5~~ 0. 001
>0. 001~ 0. 005
>0. 005 ~~0. 010
5.2 Blank test
Carry out a blank test with the sample.
5.3 Determination
GB/T 4372. 3--2001
Test material quantity·g
Measurement volume,mL
5.3.1 Place the test material (5.1) in a 150mL beaker, add 5mL nitric acid (3.1), cover with surface blood, place on a hot plate to dissolve with slight heat, after complete dissolution, remove and cool, blow water to wash the surface blood and the wall of the beaker, transfer to a 50mL volumetric flask, dilute with water to the scale and mix. 5.3.2 Use air-acetylene flame at the wavelength of 324.8nm of the atomic absorption spectrometer, adjust to zero with water, and measure the absorbance of the test solution. Subtract the absorbance of the blank test solution from the measured absorbance, and find the corresponding copper concentration from the working curve. 5.4 Drawing of working curve
5.4.1 Take 0, 2.00, 4.00, 6.00, 8.00, 10.00mL of copper standard solution (3.3) and place them in a set of 100mL volumetric flasks respectively, add 10mL of nitric acid (3.1), dilute to the scale with water, and mix well. 5.4.2 Under the same conditions as the test sample solution, measure the absorbance of the series of standard solutions. Draw the working curve with the copper concentration as the horizontal axis and the absorbance (minus the absorbance of the zero concentration solution) as the vertical axis. 6 Expression of analysis resultsbzxz.net
Calculate the mass fraction of copper oxide according to formula (1): w(Cu0) = c:V×10- ×1. 2518 ×100m
Wherein: w(CuO)
7 Allowable difference
Mass fraction of copper oxide, %;
Copper concentration obtained from the working curve, μug/mL; Volume of the measured solution, mL;
Mass of the sample, g;
Coefficient for converting copper into copper oxide.
The difference in analysis results between laboratories should not be greater than the allowable difference listed in Table 2. Table 2
Mass fraction of copper oxide
0. 000 5~~ 0. 001 0
>0. 001 0~0. 003 0
>0. 003 0~ 0. 006 0
>0. 006 0~ 0. 010 0
>0. 010 0~~0. 030 0
>0. 030 0~0. 050 0
Allowable difference
GB/T4372.3--2001
Appendix A
(Suggestive Appendix)
Instrument working conditions
The reference working conditions of GGX-5 atomic absorption spectrometer are shown in Table A1: Table A1
Wavelength, nm
Lamp current·mA
Monochromator passband, nm
Air flow, L/min
B flow, L/min
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This standard is a revision of GB/T4372.3-1984 "Zinc Oxide (Direct Method) Chemical Analysis Method Bicyclohexanone Oxalate Photometric Determination of Copper Oxide Content". The main content of the revision is the determination of copper oxide content by atomic absorption spectrometry. This standard complies with:
GB/T1467-1978 General Principles and General Provisions of Metallurgical Product Chemical Analysis Method Standard GB/T7728--1987 General Principles of Flame Atomic Absorption Spectrometry for Chemical Analysis of Metallurgical Products GB/T17433-1998 Basic Terminology for Chemical Analysis of Metallurgical Products This standard will replace GB/T4372.3-1984 from the date of implementation. Appendix A of this standard is a reminder appendix. This standard is proposed by China Nonferrous Metals Industry Association. This standard is under the jurisdiction of China Nonferrous Metals Industry Standard Metrology and Quality Research Institute. This standard is drafted by Shuikoushan Mining Bureau. The main drafters of this standard are Kuang Haiyan, Yao Xiaohong, Mao Yanling and Tan Husheng. The National Technical Committee for Standardization of Nonferrous Metals is entrusted with the interpretation of this standard. 119
1 Scope
National Standard of the People's Republic of China
Chemical analysis method of zinc oxide produced by direct process
Determination of copper oxide content by atomic absorption spectrometry
Methods for chemical analysis of zinc oxide produced by direct process- Determination of copper oxide content---Atomic absorption spectrometry method This standard specifies the method for determining the copper oxide content in zinc oxide produced by direct process. GB/T 4372.3-2001
Replaces GB/T 4372.3-1984
This standard is applicable to the determination of copper oxide content in zinc oxide produced by direct process. Determination range: 0.0005% to 0.010%. 2 Method Summary
The sample is dissolved in nitric acid. In a dilute nitric acid (5+95 medium, an air-acetylene flame is used to measure the absorbance of copper at a wavelength of 324.8nm on an atomic absorption spectrometer. The content of copper oxide is calculated using the standard curve method. 3 Reagents
3.1 Nitric acid (1+1).
3.2 Copper standard stock solution: Weigh 0.1000g of pure copper (99.99%) in a 300mL beaker, add 10mL of nitric acid (3.1), heat at low temperature to dissolve, boil to drive off nitrogen oxides, cool, transfer to a 1000mL volumetric flask, dilute to the mark with water, and mix. This solution contains 0.1 mg in 1ml. Copper.
3.3 Copper standard solution: Pipette 10.00mL of copper standard storage solution (3.2) into a 100mL volumetric flask, add 5mL of nitric acid (3.1), dilute to scale with water, and mix. This solution contains 10μg of copper in 1mL. 4 Instruments
Atomic absorption spectrometer with copper hollow cathode lamp. Under the best working conditions of the instrument, any instrument that can meet the following indicators can be used. Sensitivity: In a solution consistent with the matrix of the sample solution to be measured, the characteristic concentration of copper should not exceed 10μg. Greater than 0.035μg/mL. Precision: When the absorbance is measured 10 times with the highest concentration standard solution, the standard deviation should not exceed 1.0% of the average absorbance; when the absorbance is measured 10 times with the lowest concentration standard solution (not the zero standard solution), the standard deviation should not exceed 0.5% of the average absorbance of the highest concentration standard solution.
Linearity of working curve: Divide the working curve into five sections according to concentration. The ratio of the absorbance difference of the highest section to the absorbance difference of the lowest section should not be less than 0. 7.
For instrument working conditions, see Appendix A (indicative appendix). Approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on July 10, 2001 120
Implemented on December 1, 2001
5 Analysis steps
Weigh the sample according to Table 1, accurate to 0.0001g. Mass fraction of iron oxide, %
0. 000 5~~ 0. 001
>0. 001~ 0. 005
>0. 005 ~~0. 010
5.2 Blank test
Carry out a blank test with the sample.
5.3 Determination
GB/T 4372. 3--2001
Test material quantity·g
Measurement volume,mL
5.3.1 Place the test material (5.1) in a 150mL beaker, add 5mL nitric acid (3.1), cover with surface blood, place on a hot plate to dissolve with slight heat, after complete dissolution, remove and cool, blow water to wash the surface blood and the wall of the beaker, transfer to a 50mL volumetric flask, dilute with water to the scale and mix. 5.3.2 Use air-acetylene flame at the wavelength of 324.8nm of the atomic absorption spectrometer, adjust to zero with water, and measure the absorbance of the test solution. Subtract the absorbance of the blank test solution from the measured absorbance, and find the corresponding copper concentration from the working curve. 5.4 Drawing of working curve
5.4.1 Take 0, 2.00, 4.00, 6.00, 8.00, 10.00mL of copper standard solution (3.3) and place them in a set of 100mL volumetric flasks respectively, add 10mL of nitric acid (3.1), dilute to the scale with water, and mix well. 5.4.2 Under the same conditions as the test sample solution, measure the absorbance of the series of standard solutions. Draw the working curve with the copper concentration as the horizontal axis and the absorbance (minus the absorbance of the zero concentration solution) as the vertical axis. 6 Expression of analysis resultsbzxz.net
Calculate the mass fraction of copper oxide according to formula (1): w(Cu0) = c:V×10- ×1. 2518 ×100m
Wherein: w(CuO)
7 Allowable difference
Mass fraction of copper oxide, %;
Copper concentration obtained from the working curve, μug/mL; Volume of the measured solution, mL;
Mass of the sample, g;
Coefficient for converting copper into copper oxide.
The difference in analysis results between laboratories should not be greater than the allowable difference listed in Table 2. Table 2
Mass fraction of copper oxide
0. 000 5~~ 0. 001 0
>0. 001 0~0. 003 0
>0. 003 0~ 0. 006 0
>0. 006 0~ 0. 010 0
>0. 010 0~~0. 030 0
>0. 030 0~0. 050 0
Allowable difference
GB/T4372.3--2001
Appendix A
(Suggestive Appendix)
Instrument working conditions
The reference working conditions of GGX-5 atomic absorption spectrometer are shown in Table A1: Table A1
Wavelength, nm
Lamp current·mA
Monochromator passband, nm
Air flow, L/min
B flow, L/min
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 11755.2-1989 Medical diagnostic X-ray machine tube current test method
- JB/T 3299-1999 Manual leg-type hydraulic forklift
- NY/T 492-2002 Mango
- GB 17465.2-1998 Appliance couplers for household and similar purposes Part 2: Interconnection couplers for household and similar equipment
- GB/Z 19736-2005 Electronic imaging—Guidance for selection of document image compression methods
- GB/T 23244-2009 Fruit and vegetables - Principles and techniques of the controlled atmosphere method of storage
- QB/T 2241-1996 Alkyl cinnamaldehyde
- NY/T 1548-2007 Agricultural Technology Extensionist (Aquaculture)
- HGJ 206-1992 Chemical Machinery Installation Engineering Construction and Acceptance Specifications Small and Medium Piston Compressors
- HG/T 2129.15-1991 Acid-resistant phenolic plastics for chemical equipment parts flanged 90° elbow
- HG 21502.2-1992 Steel Vertical Cylindrical Internal Floating Roof Storage Tank Series
- GB/T 4798.6-2012 Classification of environmental conditions - Classification of groups of environmental parameters and their severities - Ship evironment
- HG/T 20572-1995 Unified regulations on the depth of content of water supply and drainage design construction drawings for chemical enterprises
- DL/T 575.12-1999 Ergonomic principles for the design of control centres Part 12 : Visual display terminal workstations
- QB/T 2371-1998 Beverage filling and capping machine
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]