JB/T 1308.18-1999 PN250a reducer types, dimensions and technical requirements
time:
1999-07-12 15:00:00
- JB/T 1308.18-1999
- in force
Standard ID:
JB/T 1308.18-1999
Standard Name:
PN250a reducer types, dimensions and technical requirements
Chinese Name:
PN250a 异径接头型式、尺寸和技术条件
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1999-07-12 -
Date of Implementation:
2000-01-01
Standard ICS number:
Fluid Systems and General Parts >> 23.060 ValvesChina Standard Classification Number:
Machinery>>General Parts>>J16 Valve
alternative situation:
JB 1325-1973
Focal point Organization:
National Valve Standardization Technical CommitteePublishing Department:
National Valve Standardization Technical Committee

Skip to download
Summary:
JB/T 1308.18-1999 This standard is a revision of JB 1325-73 "Type, size and technical requirements of Pg (2500kgf/cm2) reducers". This standard specifies the type, size and technical requirements of reducers for ultra-high pressure valves. This standard is applicable to reducers for neutral media such as ethylene and polyethylene with a nominal pressure of 250MPa. This standard was first published on 2010-03-17. JB/T 1308.18-1999 PN250a reducer type, size and technical requirements JB/T1308.18-1999 standard download decompression password: www.bzxz.net

Some standard content:
ICS23.060
Machinery Industry Standard of the People's Republic of China
JB/T1308.1~1308.21-1999
PN250MPa ultrahigh pressure valves and fittings
Technical conditions
Specifications for PN250MPa ultrahigh pressure valves and fittings
1999-07-12 Issued
State Bureau of Machinery Industry
Implementation on 2000-01-01
1 Scope
Machinery Industry Standard of the People's Republic of China
PN250MPa reduced joints
Type, dimensions and specifications of PN 250 MPa reduced joints This standard specifies the types, dimensions and technical requirements of reducing joints for ultrahigh pressure valves. JB/T1308.18—1999
Replaces JB1325—73
This standard applies to reducers for neutral media such as ethylene and polyethylene with a nominal pressure of PN250MPa. 2 Cited standards
The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest versions of the following standards. JB/1308.2—1999PN250MPa Technical conditions for valves, pipe fittings and fasteners JB/T1308.4—1999PN250MPa Neck joint types, dimensions and technical conditions Structural types and dimensions
3.1 The type of reducer shall be as specified in Figure 1. Its bearing capacity is 8 levels A, maintaining the angle of loss. Approved by the State Machinery Industry Bureau on 1999-07-12, 38, Baoshenyu, implemented on 2000-01-01. The dimensions of the reducer shall be as specified in Table 1.
Nominal diameter
10 ×3
15 ×10
Nominal diameter
10 ×3
10 ×6
15 ×10
Thread code
M24 × 22
M33 × 2-2
M48 × 22
4Technical requirements
Thread code
M20 ×1.52
M24 ×22www.bzxz.net
M33 ×22
Material of reducing joint 33CrNi3MoA.
JB/T1308.18-1999
The mechanical properties after heat treatment shall be as specified in Table 2. 4.2
Material grade
33CrNi3MoA
Tensile strength.
Service point. .
≥735
The end of the reducer shall comply with the provisions of JB/T1308.4. 4.3
Elongation 8,
Contraction rate medium
4.4The reducer shall be subjected to ultrasonic flaw detection and magnetic particle flaw detection in accordance with the provisions of JB/T1308.2. d,
Impact value A
269~321
4.5Each reducer shall be stamped with a steel stamp on the outer surface (at the mark in the figure), and the stamp content shall be: JB/T1308.18 specification/batch number. 5 Marking example
Reducing joint with nominal diameter 10×6mm:
5JB/T1308.18—1999
Reducing joint DN10×6
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of China
JB/T1308.1~1308.21-1999
PN250MPa ultrahigh pressure valves and fittings
Technical conditions
Specifications for PN250MPa ultrahigh pressure valves and fittings
1999-07-12 Issued
State Bureau of Machinery Industry
Implementation on 2000-01-01
1 Scope
Machinery Industry Standard of the People's Republic of China
PN250MPa reduced joints
Type, dimensions and specifications of PN 250 MPa reduced joints This standard specifies the types, dimensions and technical requirements of reducing joints for ultrahigh pressure valves. JB/T1308.18—1999
Replaces JB1325—73
This standard applies to reducers for neutral media such as ethylene and polyethylene with a nominal pressure of PN250MPa. 2 Cited standards
The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest versions of the following standards. JB/1308.2—1999PN250MPa Technical conditions for valves, pipe fittings and fasteners JB/T1308.4—1999PN250MPa Neck joint types, dimensions and technical conditions Structural types and dimensions
3.1 The type of reducer shall be as specified in Figure 1. Its bearing capacity is 8 levels A, maintaining the angle of loss. Approved by the State Machinery Industry Bureau on 1999-07-12, 38, Baoshenyu, implemented on 2000-01-01. The dimensions of the reducer shall be as specified in Table 1.
Nominal diameter
10 ×3
15 ×10
Nominal diameter
10 ×3
10 ×6
15 ×10
Thread code
M24 × 22
M33 × 2-2
M48 × 22
4Technical requirements
Thread code
M20 ×1.52
M24 ×22www.bzxz.net
M33 ×22
Material of reducing joint 33CrNi3MoA.
JB/T1308.18-1999
The mechanical properties after heat treatment shall be as specified in Table 2. 4.2
Material grade
33CrNi3MoA
Tensile strength.
Service point. .
≥735
The end of the reducer shall comply with the provisions of JB/T1308.4. 4.3
Elongation 8,
Contraction rate medium
4.4The reducer shall be subjected to ultrasonic flaw detection and magnetic particle flaw detection in accordance with the provisions of JB/T1308.2. d,
Impact value A
269~321
4.5Each reducer shall be stamped with a steel stamp on the outer surface (at the mark in the figure), and the stamp content shall be: JB/T1308.18 specification/batch number. 5 Marking example
Reducing joint with nominal diameter 10×6mm:
5JB/T1308.18—1999
Reducing joint DN10×6
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 15050-1994 Hand-knotted wool carpets
- GB/T 17557-1998 Insulation materials for marine power cables
- SY 6516-2001 Safety regulations for electric welding in the petroleum industry
- GB/T 548-1996 Anchor Technical Requirements
- HG/T 20521-1992 Chemical Steam System Design Regulations
- GB/T 39623-2020 Quality testing and evaluation of fundamental geographic information database system
- QB/T 1631-1992 Sandalwood 208
- SY/T 4103-1995 Steel pipeline welding and acceptance
- GB/T 4549.7-2004 Vocabulary of railway vehicles Part 7: Heating, ventilation and air conditioning equipment
- GB 15931-1995 Test methods for smoke exhaust fire dampers
- JB/T 8034-1999 Machine tool fixture parts and components hinge supports
- QB/T 1588.1-1992 General technical requirements for welding parts of light industrial machinery
- SY/T 0017-1996 Technical standard for direct current protection of buried steel pipelines
- JB/T 7517-1994 Mechanical product reliability design review
- JJG 967-2001 Verification Regulation of Calibrators for Headlamp Tester of Motor Vehicle
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]