GB 16183-1996 Hygienic standard for thallium in workshop air
time:
2024-08-06 06:57:37
- GB 16183-1996
- in force
Standard ID:
GB 16183-1996
Standard Name:
Hygienic standard for thallium in workshop air
Chinese Name:
车间空气中铊卫生标准
Standard category:
National Standard (GB)
-
Date of Release:
1996-04-03 -
Date of Implementation:
1996-09-01
Standard ICS number:
Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplaceChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
alternative situation:
Partially replaced by GBZ/T 160.21-2004
publishing house:
China Standards PressISBN:
155066.1-12962Publication date:
2004-04-10
Release date:
1996-04-03Review date:
2004-10-14Drafting Organization:
Beijing Institute of Labor Hygiene and Occupational DiseasesFocal point Organization:
Ministry of HealthPublishing Department:
State Administration of Technical Supervision Ministry of Health of the People's Republic of ChinaCompetent Authority:
Ministry of Health

Skip to download
Summary:
This standard specifies the maximum permissible concentration of thallium and its compounds in the air of a workplace and the monitoring and testing methods. This standard is applicable to all types of enterprises that produce and use thallium and its compounds. GB 16183-1996 Health Standard for Thallium in Workshop Air GB16183-1996 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Health standard for thallium in the air of workplace
Health standard for thallium in the air of workplaceSubject content and scope of application
GB16183-1996
This standard specifies the maximum permissible concentration of thallium and its compounds in workplace air and the blue test method. This standard applies to all types of enterprises that produce and use thallium and its compounds. 2 Hygiene requirements
The maximum permissible concentration of thallium in workplace air (in thallium) is 0.01mg/m (skin). 3
Monitoring and testing methods
The monitoring and testing methods of this standard adopt the stone furnace atomic absorption method, see Appendix A. 4 Supervision and implementation
Labor health and occupational health prevention agencies at all levels and health and epidemic prevention agencies at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996, and implemented on September 1, 1996
A1 Principle
GB16183-1996
Appendix A
Determination of thallium in air by atomic absorption method
(Supplement)
Use the single chromatographic line of the thallium hollow cathode lamp to be absorbed by atoms in the graphite furnace atomizer, and determine its spectral line intensity and compare it with the standard sample for quantitative determination.
The minimum detection concentration of this method is 10-2mg/m. A2 Instruments
A2.1 Atomic absorption instrument: Zeeman background correction graphite furnace atomic absorption instrument or chlorine lamp background correction graphite furnace atomic absorption instrument; hollow cathode lamp; non-pyrolytic graphite tube.
A2.2 Dust sampler.
A2.3 10mL centrifuge tube with stopper.
A2.449\Glass fiber filter paper.
A2.5 Adjustable micro-liquidator.
A3 Reagents
A3.1 Thallium carbonate or thallium sulfate, spectrally pure or analytically pure, use 5 mol/L nitric acid to make a stock solution of 1 mL 1 mg thallium, store in a refrigerator at 4C, and dilute with deionized water before analysis.
A3.2 Nitric acid, high-grade pure.
A4 Sampling
Install a single layer of glass fiber filter paper on the sampling head and collect air at a suction speed of 20 to 30 L/min for 20 to 30 minutes. Collect air samples at the pre-set sampling points, and record the temperature and air pressure conditions at the time and location. A5 Analysis steps
A5.1 Atomic absorption instrument parameters:
Wavelength 276.7 nm.
F-drying 80-120℃20s;120℃10s.
Ashing 120~300℃20s;300℃10s. Atomization 1800℃5s (gas off).
Heat removal 2400℃2s.
A5.2 Sample analysis
Fold the filter paper of the sample several times, put it into a 10mL centrifuge tube, dissolve it with 0.5mol/L nitric acid 5mL, shake it vigorously, shake the glass fiber filter paper thoroughly, let it stand for 3~5min, wait for the fiber to sink, take 25μL of the supernatant and inject it into the graphite tube. If the sample content is too high, it needs to be diluted before injection.
A5.3 Drawing of standard curve
Use 0.5mol/L nitric acid solution to dilute the thallium stock solution into a series of 0, 25, 50, 75, 100μg/L. Use a plastic adjustable micro-injector to draw 25 μl and inject it into the graphite tube. Repeat the same operation for seven days, merge the data, perform regression analysis on the concentration based on the absorbance value, and draw a standard curve for use when monitoring samples. 380
A6 Calculation
Where X-
-the concentration of thallium in the air, mg/m2;
GB16183-1996wwW.bzxz.Net
(————Concentration obtained from the standard curve, μg/I; K-sample dilution factor during injection;
V. —Volume of sample collected under standard conditions, L. A7 Precautions
A7.1 Carbide is a volatile element, so the temperature during ashing should not exceed 300°C, otherwise it will be lost. A7.2 Avoid using hydrochloric acid or perchloric acid during sample processing. Additional notes:
This standard was proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by the Beijing Institute of Labor Hygiene and Occupational Disease Prevention and Control. The main drafters of this standard were Cui Mingzhen and Chen Zhenyang. (A1)
This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, which is the technical management unit entrusted by the Ministry of Health. 381
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Health standard for thallium in the air of workplace
Health standard for thallium in the air of workplaceSubject content and scope of application
GB16183-1996
This standard specifies the maximum permissible concentration of thallium and its compounds in workplace air and the blue test method. This standard applies to all types of enterprises that produce and use thallium and its compounds. 2 Hygiene requirements
The maximum permissible concentration of thallium in workplace air (in thallium) is 0.01mg/m (skin). 3
Monitoring and testing methods
The monitoring and testing methods of this standard adopt the stone furnace atomic absorption method, see Appendix A. 4 Supervision and implementation
Labor health and occupational health prevention agencies at all levels and health and epidemic prevention agencies at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996, and implemented on September 1, 1996
A1 Principle
GB16183-1996
Appendix A
Determination of thallium in air by atomic absorption method
(Supplement)
Use the single chromatographic line of the thallium hollow cathode lamp to be absorbed by atoms in the graphite furnace atomizer, and determine its spectral line intensity and compare it with the standard sample for quantitative determination.
The minimum detection concentration of this method is 10-2mg/m. A2 Instruments
A2.1 Atomic absorption instrument: Zeeman background correction graphite furnace atomic absorption instrument or chlorine lamp background correction graphite furnace atomic absorption instrument; hollow cathode lamp; non-pyrolytic graphite tube.
A2.2 Dust sampler.
A2.3 10mL centrifuge tube with stopper.
A2.449\Glass fiber filter paper.
A2.5 Adjustable micro-liquidator.
A3 Reagents
A3.1 Thallium carbonate or thallium sulfate, spectrally pure or analytically pure, use 5 mol/L nitric acid to make a stock solution of 1 mL 1 mg thallium, store in a refrigerator at 4C, and dilute with deionized water before analysis.
A3.2 Nitric acid, high-grade pure.
A4 Sampling
Install a single layer of glass fiber filter paper on the sampling head and collect air at a suction speed of 20 to 30 L/min for 20 to 30 minutes. Collect air samples at the pre-set sampling points, and record the temperature and air pressure conditions at the time and location. A5 Analysis steps
A5.1 Atomic absorption instrument parameters:
Wavelength 276.7 nm.
F-drying 80-120℃20s;120℃10s.
Ashing 120~300℃20s;300℃10s. Atomization 1800℃5s (gas off).
Heat removal 2400℃2s.
A5.2 Sample analysis
Fold the filter paper of the sample several times, put it into a 10mL centrifuge tube, dissolve it with 0.5mol/L nitric acid 5mL, shake it vigorously, shake the glass fiber filter paper thoroughly, let it stand for 3~5min, wait for the fiber to sink, take 25μL of the supernatant and inject it into the graphite tube. If the sample content is too high, it needs to be diluted before injection.
A5.3 Drawing of standard curve
Use 0.5mol/L nitric acid solution to dilute the thallium stock solution into a series of 0, 25, 50, 75, 100μg/L. Use a plastic adjustable micro-injector to draw 25 μl and inject it into the graphite tube. Repeat the same operation for seven days, merge the data, perform regression analysis on the concentration based on the absorbance value, and draw a standard curve for use when monitoring samples. 380
A6 Calculation
Where X-
-the concentration of thallium in the air, mg/m2;
GB16183-1996wwW.bzxz.Net
(————Concentration obtained from the standard curve, μg/I; K-sample dilution factor during injection;
V. —Volume of sample collected under standard conditions, L. A7 Precautions
A7.1 Carbide is a volatile element, so the temperature during ashing should not exceed 300°C, otherwise it will be lost. A7.2 Avoid using hydrochloric acid or perchloric acid during sample processing. Additional notes:
This standard was proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by the Beijing Institute of Labor Hygiene and Occupational Disease Prevention and Control. The main drafters of this standard were Cui Mingzhen and Chen Zhenyang. (A1)
This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, which is the technical management unit entrusted by the Ministry of Health. 381
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG 3303-1990 Trichloroacetic Acaricide (formerly ZB G25 015-90)
- GB/T 4955-1997 Metallic coatings-Measurement of coating thickness-Coulometric method by anodic dissolution
- JB/T 7008-1993 ZC1 double-stage worm and gear worm reducer
- CB/T 3324-1995 Precision requirements for steel outfitting parts
- JB/T 7513-1994 Taper sleeve types, dimensions and basic parameters
- GB/T 17248.4-1998 Acoustics--Noise emitted by machinery and equipment--Determination of emission sound pressure level at a workstation and at other specified position from the sound power level
- GB/T 5059.5-1986 Chemical analysis methods for ferromolybdenum - Gravimetric method for determination of silicon content
- GB/T 5499-1985 Inspection of grains and oilseeds - Inspection method for pure kernel rate of shelled oilseeds
- JB/T 8350.1-1996 Cupola charging machine types and basic parameters
- GB/T 3434-1986 Semiconductor integrated circuit ECL circuit series and varieties
- GB 12262-1990 Heat exchangers for artificial heart-lung machines
- GB 12768-1991 重熔用电工铝锭
- QB 1801-1993 White Orchid Oil
- HG 2955-1989 Rules for the preparation of standards for molecular absorption spectroscopy analysis methods
- GB/T 11805-1999 Basic technical requirements for automation components (devices) and systems of hydro-generator sets
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]