GB 10493-1989 Technical requirements for railway station crossing signal equipment
time:
1989-03-22 16:00:00
- GB 10493-1989
- in force
Standard ID:
GB 10493-1989
Standard Name:
Technical requirements for railway station crossing signal equipment
Chinese Name:
铁路站内道口信号设备技术条件
Standard category:
National Standard (GB)
-
Date of Release:
1989-03-22 -
Date of Implementation:
1989-10-01
Standard ICS number:
Sociology, services, organization and management of companies (enterprises), administration, transportation>>Transportation>>03.220.30 Railway transportationChina Standard Classification Number:
Railway>>Railway Signaling>>S61 Signaling Equipment
Release date:
1989-03-22Review date:
2004-10-14Drafting Organization:
Ministry of Railways Communications and Signaling CompanyFocal point Organization:
Ministry of RailwaysPublishing Department:
State Bureau of Technical SupervisionCompetent Authority:
Ministry of Railways

Skip to download
Summary:
This standard specifies the terminology and technical conditions for crossing signals in railway stations. This standard is applicable to guarded railway station crossings and is a technical guideline for the study and design of station crossing signals and the section of adjacent station crossing signals notified by the station. The crossing signaling equipment is a safety protection facility installed at railway crossings. Industrial and mining enterprise railways can also refer to the implementation. GB 10493-1989 Technical conditions for crossing signaling equipment in railway stations GB10493-1989 Standard download and decompression password: www.bzxz.net

Some standard content:
CAS | It was approved by the National Standardization Administration Committee on May 19, 2005 in the National Standards Committee Gongjiaohan [2005] No. 24 document, and will be implemented from August 1, 2005. www.bzxz.net
Standard name: GB10493-1989 "Technical Conditions for Signaling Equipment at Crossings in Railway Stations" 1. Delete the words "According to the guarding situation" in Article 3.1: "Guarded crossings and 'Unguarded crossings'". ", modified to: "3.1 Railway crossing
refers to the railway pavement width of 2.5m or more, which directly intersects with the plane connected by the road. 2. Delete Article 4.3.3.
3. In the article "4.4.2 Light Display"
1) Delete column a;
2) Delete "moon white light goes out," in column b and modify it to "b. When the crossing is notified of the approaching train, two red lights flash alternately (when the flashing system fails, a steady red light is displayed)."; 3) List item c is modified to "c. When the power supply or equipment fails, the guard should be alerted If the operator receives equipment failure information, the warden promptly gives the message "Equipment failure, pay attention to the train sign" in the direction of the road. After the fault is repaired, "Equipment failure, please note that the train identification will be manually canceled." 4. In the article "4.16.2 Crossing Signals", 1) delete column a;
2) delete "the straight line display distance of the white light should not be less than 50m," in column b, and change it to "b. The straight line display distance of the red light is not less than 100m, and the deviation angle is not less than 40°.” 5. Delete column f in Article 4.19.1. 6. Delete item g in Article 4.19.2. Published in the 7th issue of "China Standardization" in 2005 50
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Standard name: GB10493-1989 "Technical Conditions for Signaling Equipment at Crossings in Railway Stations" 1. Delete the words "According to the guarding situation" in Article 3.1: "Guarded crossings and 'Unguarded crossings'". ", modified to: "3.1 Railway crossing
refers to the railway pavement width of 2.5m or more, which directly intersects with the plane connected by the road. 2. Delete Article 4.3.3.
3. In the article "4.4.2 Light Display"
1) Delete column a;
2) Delete "moon white light goes out," in column b and modify it to "b. When the crossing is notified of the approaching train, two red lights flash alternately (when the flashing system fails, a steady red light is displayed)."; 3) List item c is modified to "c. When the power supply or equipment fails, the guard should be alerted If the operator receives equipment failure information, the warden promptly gives the message "Equipment failure, pay attention to the train sign" in the direction of the road. After the fault is repaired, "Equipment failure, please note that the train identification will be manually canceled." 4. In the article "4.16.2 Crossing Signals", 1) delete column a;
2) delete "the straight line display distance of the white light should not be less than 50m," in column b, and change it to "b. The straight line display distance of the red light is not less than 100m, and the deviation angle is not less than 40°.” 5. Delete column f in Article 4.19.1. 6. Delete item g in Article 4.19.2. Published in the 7th issue of "China Standardization" in 2005 50
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 4343-1995 Measurement methods and allowable values ??for radio interference characteristics of household and similar electric and heating appliances, power tools and similar electrical appliances
- JB/T 6755-1993 Diesel generator set switchgear
- GB 8137-1987 Granular shellac
- GB 16798-1997 Food machinery safety and sanitation
- GB 18661-2002 Single-ended metal halide lamp (175W~1500W scandium sodium series)
- QB/T 1528-1992 Four-roller glue coating machine
- GB/T 2260-2002 Codes for the administrative divisions of the Peoples Republic of China
- GB/T 15663.4-1995 Terminology of coal mining technology - Open-pit mining
- JB/T 5247.2-1998 Basic parameters of desktop press type
- JB/T 9576-2000 Large and medium-sized turbine inlet valve series
- GB 474-1996 Coal sample preparation method
- SY/T 5097-1996 Technical requirements for multi-parameter instruments for drilling (repair) wells
- GB/T 15650-1995 Series and varieties of semiconductor integrated circuits Series and varieties of CMOS gate array circuits
- JJF 1030-2010 Measurement and Test Norm of Thermostatic Bath’s Metrological Characteristics
- SY 5670-1993 Petroleum and liquid petroleum products railway tank car transfer measurement procedures
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com