JB/T 5288.1-1991 Cycloidal pinwheel reducer temperature rise measurement method
time:
1991-07-22 16:00:00
- JB/T 5288.1-1991
- in force
Standard ID:
JB/T 5288.1-1991
Standard Name:
Cycloidal pinwheel reducer temperature rise measurement method
Chinese Name:
摆线针轮减速机 温升测定方法
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1991-07-22 -
Date of Implementation:
1992-07-01
China Standard Classification Number:
Machinery>>General Parts>>J19 Couplings, Brakes and Transmissions
Drafter:
Yang Yinsheng, Duan BingjunDrafting Organization:
Tianjin Petrochemical General Machinery Research InstituteFocal point Organization:
Tianjin Petrochemical General Machinery Research InstituteProposing Organization:
Tianjin Petrochemical General Machinery Research InstitutePublishing Department:
Ministry of Electronic Industry of the People's Republic of China

Skip to download
Summary:
This standard specifies the environmental conditions, measurement methods and judgment of the measurement results for the temperature rise measurement of cycloidal pinwheel reducers. This standard applies to reducers lubricated with lubricating oil. JB/T 5288.1-1991 Cycloidal pinwheel reducer temperature rise measurement method JB/T5288.1-1991 Standard download and decompression password: www.bzxz.net

Some standard content:
Machinery Industry Standard of the People's Republic of China
Cycloidal pinwheel reducer
1 Subject content and scope of application
Temperature rise measurement method
JB/T 5288.1||tt| |91
This standard specifies the environmental conditions, measurement methods and judgment of the measurement results for the temperature rise measurement of the cycloidal wheel reducer (hereinafter referred to as the reducer).
This standard applies to reducers lubricated with lubricating oil. 2 Reference standards
I13/T5288.3 Determination method of load carrying capacity and transmission efficiency of cycloidal wheel reducer 3 Environmental conditions and temperature measurement points
3.1 Environmental conditions
3.1.1 minus The measurement of reverse engine temperature rise should be carried out in a room that is not affected by the outside temperature. The indoor ambient temperature should be within the range of 5 to 40 degrees Celsius. 3.1.2 Free air circulation in the air + strong headflow is not allowed. 3.2 Measurement Temperature point
The temperature measurement point should be selected where the thermometer can contact the reducer lubricating oil: 4 Thermometer wwW.bzxz.Net
The graduation law is 0.5C,
5 Measurement method ||tt| |5.1 .Measurement of temperature
5.1.1 Determination of the temperature rise of the reducer under test. It is usually carried out at the same time as the load capacity and transmission efficiency of the reducer, but can also be carried out separately. 5.1.2 Reducer under test When complying with the provisions of 8.2.3 in B3/T5288.3, ??read the .1 operating temperature of the reducer at rated speed and rated input power
5.2 Determination of ambient temperature
5.2. 1. Place a thermometer 1.5m away from the surface of the reducer being measured. The height of the tide meter measuring point from the ground is the same as the axis of the reducer. 5.2.2 The placement of the overflow meter should not be affected by external radiant heat and airflow. 5.2.3 The reading of the ambient temperature value and the reading of the operating temperature value should be carried out at the same time. 6 Temperature rise calculation
The temperature rise is calculated according to the following formula:
A=t, ||tt| |The Ministry of Mechanical and Electronics Industry of the People's Republic of China approved 18
1991-07-01 implementation
Wuzhong: At-
·Reducer Temperature rise,;
JB/T5288.1-91
The operating temperature of the reducer at rated speed and rated input power. (:Ambient temperature, (.
Test results The judgment of
The judgment of temperature rise test results should comply with the provisions of the national standard cycloidal pinwheel reducer
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Cycloidal pinwheel reducer
1 Subject content and scope of application
Temperature rise measurement method
JB/T 5288.1||tt| |91
This standard specifies the environmental conditions, measurement methods and judgment of the measurement results for the temperature rise measurement of the cycloidal wheel reducer (hereinafter referred to as the reducer).
This standard applies to reducers lubricated with lubricating oil. 2 Reference standards
I13/T5288.3 Determination method of load carrying capacity and transmission efficiency of cycloidal wheel reducer 3 Environmental conditions and temperature measurement points
3.1 Environmental conditions
3.1.1 minus The measurement of reverse engine temperature rise should be carried out in a room that is not affected by the outside temperature. The indoor ambient temperature should be within the range of 5 to 40 degrees Celsius. 3.1.2 Free air circulation in the air + strong headflow is not allowed. 3.2 Measurement Temperature point
The temperature measurement point should be selected where the thermometer can contact the reducer lubricating oil: 4 Thermometer wwW.bzxz.Net
The graduation law is 0.5C,
5 Measurement method ||tt| |5.1 .Measurement of temperature
5.1.1 Determination of the temperature rise of the reducer under test. It is usually carried out at the same time as the load capacity and transmission efficiency of the reducer, but can also be carried out separately. 5.1.2 Reducer under test When complying with the provisions of 8.2.3 in B3/T5288.3, ??read the .1 operating temperature of the reducer at rated speed and rated input power
5.2 Determination of ambient temperature
5.2. 1. Place a thermometer 1.5m away from the surface of the reducer being measured. The height of the tide meter measuring point from the ground is the same as the axis of the reducer. 5.2.2 The placement of the overflow meter should not be affected by external radiant heat and airflow. 5.2.3 The reading of the ambient temperature value and the reading of the operating temperature value should be carried out at the same time. 6 Temperature rise calculation
The temperature rise is calculated according to the following formula:
A=t, ||tt| |The Ministry of Mechanical and Electronics Industry of the People's Republic of China approved 18
1991-07-01 implementation
Wuzhong: At-
·Reducer Temperature rise,;
JB/T5288.1-91
The operating temperature of the reducer at rated speed and rated input power. (:Ambient temperature, (.
Test results The judgment of
The judgment of temperature rise test results should comply with the provisions of the national standard cycloidal pinwheel reducer
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 16006-1995 Standard for Elimination of Iodine Deficiency Disorders
- GB 9053-1998 Stabilized light hydrocarbons
- GB/T 11798.1-2001 Technical requirements for the verification of motor vehicle safety testing equipment Part 1: Technical requirements for the verification of a skateboard-type vehicle side slip test bench
- GB/T 14501.6-1994 Determination of uranium in uranium hexafluoride
- HG/T 3132-1998 L-type cooling tower fan
- GB/T 20523-2006 Composition and calculation of enterprise logistics cost
- GB 17859-1999 Criteria for the classification of computer information system security protection levels
- QB/T 3599-1999 Sensory inspection of canned food
- JB/T 7658.9-1995 Low-pressure circulating liquid receiver for ammonia refrigeration equipment
- HG/T 2638-1994 Quality classification of glass-lined equipment
- GBJ 117-1988 Standard for seismic evaluation of industrial structures
- JB/T 5947-1991 General technical requirements for packaging of construction machinery
- JB/T 6989-2002 Rotary cone crusher
- GB 6465-1986 Metallic and other non-organic coatings; Corrodokote corrosion test(CORR test)
- GB 18483-2001 Emission standard for cooking fumes in the catering industry