HG 21590-1995 Reflection glass plate liquid level gauge (PN4.0)
time:
2024-08-13 14:41:11
- HG 21590-1995
- in force
Standard ID:
HG 21590-1995
Standard Name:
Reflection glass plate liquid level gauge (PN4.0)
Chinese Name:
反射式玻璃板液面计(PN4.0)
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1996-11-27 -
Date of Implementation:
1996-03-01
Standard ICS number:
Chemical Technology>>71.120 Chemical EquipmentChina Standard Classification Number:
Chemical Industry>>Chemical Machinery and Equipment>>G91 Chemical Machinery and Equipment Parts
alternative situation:
HG 5-1363~1370-1980 HG 5-227-1980
publishing house:
Engineering Construction Standards Editing Center of the Ministry of Chemical Industry
Skip to download
Summary:
This standard specifies the type, size, technical requirements and selection regulations of reflective glass plate liquid level gauges with a nominal pressure of 4.0 MPa. HG 21590-1995 Reflective glass plate liquid level gauge (PN4.0) HG21590-1995 Standard download decompression password: www.bzxz.net
Some standard content:
Reflection glass plate liquid level gauge
(PN4.0)
HG 21590—95
Subject content and scope of application
This standard specifies the type, size, technical requirements and selection regulations of reflection glass plate liquid level gauge with a nominal pressure of 4.0MPa1. 0. 1
. The nominal pressure of this standard is 4. 0MPs, and the operating temperature is 0~250℃; when the operating temperature exceeds 200C, the maximum allowable (impact-free) operating pressure shall be determined in Table 1.0.3 of HG21588-95#5 standard.
The corrosion margin in this standard shall be as specified in Table 1.0.2. 1.0.2
Table1.0.2
Material code
Stainless copper1
Corrosion allowance
Reference standard
HG21588-95 Standard series and technical requirements for glass plate fatigue gauge\t
Structural type, basic parameters and dimensions
The structural types of this standard are two types of liquid level gauges: "bottom with valve" and "bottom with screw plug", which are respectively "ordinary type" and "insulation type". The parameters and dimensions are shown in Table 3.0.1 and Figure 3.0.1. 3.0.2 The glass plate is in accordance with QB776-80 "Glass plate and glass tube for liquid level gauge" standard, and the specification number is R280.
Basic parameters and dimensions of reflective glass plate liquid level gauge (PIN4.0) Table 3. 0. 1
Hot steam pipe
(kg)
Liquid level gaugeLoose lengthTransparent sizeTransparent total lengthBottom valve with bottom screw plug
Interface spacing:
NumberL(mm)LX14(mm)
260×14
260×14
260×14
260×14
260×14
Ordinary typeInsulation typeOrdinary typeInsulation type
19.719. 617.7
28. 326. 2
Carbon steel (Class I), stainless steel (Class I) liquid level gauges have the same weight, 109
Uniform distribution in the span
-253 (open)
-Middle 18
Uniform distribution in the road
Insulation type
Ordinary type
A (B center) needle valve (part number) with valve type
Port material-120
4 (BC) needle valve (part number 1 or part number 9)
.6×1.3|| tt||Figure 3.0.1 (continued)
Structural diagram of reflection type glass plate liquid level gauge (PN4.0) 2
Sealing welding
Copper welding (melting electrode automatic argon arc welding)
Heating hot steam pipe interface
Copper welding (melting electrode automatic argon arc welding)
Heating steam general interface
Figure 3.0.1 (continued) Structural diagram of primary reflection type glass plate liquid level gauge (IN4.0) t
Technical requirements
Should comply with HG 21588-95 {Glass Plate Liquid Level Gauge Standard Series and Technical Requirements》.
Selection Regulations
Flange size and type for external connection
The nominal diameter of the flange is DN20 or 3/4\. 5.1.1
5.1.2The flange types are A, B and C, and their connection dimensions are as follows: Type A: Raised face flange (RF), according to HGJ50-91, PN6.3 Type B: Raised face flange (M), according to HGJ 51-91, PN6.3; Type C: Raised face flange (RF), according to ANSIB16.5W.N.300#. 5.2
This standard uses flexible graphite composite gaskets. Users can choose to replace materials with a preload pressure less than or equal to 48.5MPa and a gasket coefficient m less than or equal to 2 according to operating conditions and medium characteristics, but it must be indicated in the assembly drawing of the equipment. 5.3 Marking and specifications
Marking regulations and examples shall comply with the relevant regulations in HG21588-95. 5.3.2 Liquid level gauges of various specifications in this standard shall be selected according to Table 5.3.2 and indicated in the details column of the equipment assembly drawing.
Capsule 5.3.2 Specifications and markings for reflective glass-filled liquid level gauges (PN4.0)
Liquid level gauge A (B, C) R4.0-I -550V(P)
R4.0-1 850V(P)
Liquid level gauge A (B, C)
R4.0-- 1 -1150V(P)
R4.0-I -1450V(P)
Liquid level gauge A (B, C)
R4.0-- 1 -1750V(P)
Liquid level gauge A (BC)
R4.0-I -550V(P)
A(B,C)
Hidden surface meter
R4. 0- 1 -850V(P)
Axillary surface meter
R4. 0-I -1150V(P)
Wind surface meterA(B,C)
Hidden surface meter
A(B,C)
R4. 0— 1 -1450V(P)
Liquid level meter
R4. 0- -1750V(P)
Axillary surface meter
R4.0- I - 550V(P)
R4. 0- IW -- 850V(P)
Quilt surface gauge A(B,C)
R4, 0- 1 W-1150V(P)
Liquid level gauge
R4. 0-1W-1450V(P)
Cross surface gauge A(B,C)
Liquid level gauge A(B,C)
R4, 0- 1 W- 1750V(P)
Liquid level gauge
R4. 0- IW -- 550V(P)
R4. -- I W--850V(P)
Axillary surface gauge
A(B,C)
Liquid level gauge A(B,C)bzxZ.net
R4, 0- Iw-1150V(P)
Quilt surface meter A(B,C)
R4. 0- I W-1450V(P)
Surface meter
R4. 0- I W-1750V(P)
Standard drawing (i.e. construction drawing) drawing number
HG 21590—95-1
HG 21590-95-2
HG 21590-95—3
HG 21590- 95—4
HG 21590- 955
HG 21590-95-6
HG 21590-95-7
HG 21590-95--8
HG 21590- 95 -- 9
HG 21590-95-10
HG 21590—95—11
HG 21590—95—12
HG 21590— 95-13
HG 21590— 95—14
HG 21590—95—15
HG 21590-95-16
HG 21590—95-17
HG 21590-95-18
HG 21590-95—19
HG 21590—95—20
Additional Notes
The unit proposing this standard, the editor-in-chief
and the main drafters
Ministry of Equipment Investment and Technology Center
Global Chemical Engineering Corporation
Main drafters
Wang Xiaohua
Xue Tijun
Kong Xianglin
Bang Pichang
Xu Zhiyuan
Zou Zhiguang
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
(PN4.0)
HG 21590—95
Subject content and scope of application
This standard specifies the type, size, technical requirements and selection regulations of reflection glass plate liquid level gauge with a nominal pressure of 4.0MPa1. 0. 1
. The nominal pressure of this standard is 4. 0MPs, and the operating temperature is 0~250℃; when the operating temperature exceeds 200C, the maximum allowable (impact-free) operating pressure shall be determined in Table 1.0.3 of HG21588-95#5 standard.
The corrosion margin in this standard shall be as specified in Table 1.0.2. 1.0.2
Table1.0.2
Material code
Stainless copper1
Corrosion allowance
Reference standard
HG21588-95 Standard series and technical requirements for glass plate fatigue gauge\t
Structural type, basic parameters and dimensions
The structural types of this standard are two types of liquid level gauges: "bottom with valve" and "bottom with screw plug", which are respectively "ordinary type" and "insulation type". The parameters and dimensions are shown in Table 3.0.1 and Figure 3.0.1. 3.0.2 The glass plate is in accordance with QB776-80 "Glass plate and glass tube for liquid level gauge" standard, and the specification number is R280.
Basic parameters and dimensions of reflective glass plate liquid level gauge (PIN4.0) Table 3. 0. 1
Hot steam pipe
(kg)
Liquid level gaugeLoose lengthTransparent sizeTransparent total lengthBottom valve with bottom screw plug
Interface spacing:
NumberL(mm)LX14(mm)
260×14
260×14
260×14
260×14
260×14
Ordinary typeInsulation typeOrdinary typeInsulation type
19.719. 617.7
28. 326. 2
Carbon steel (Class I), stainless steel (Class I) liquid level gauges have the same weight, 109
Uniform distribution in the span
-253 (open)
-Middle 18
Uniform distribution in the road
Insulation type
Ordinary type
A (B center) needle valve (part number) with valve type
Port material-120
4 (BC) needle valve (part number 1 or part number 9)
.6×1.3|| tt||Figure 3.0.1 (continued)
Structural diagram of reflection type glass plate liquid level gauge (PN4.0) 2
Sealing welding
Copper welding (melting electrode automatic argon arc welding)
Heating hot steam pipe interface
Copper welding (melting electrode automatic argon arc welding)
Heating steam general interface
Figure 3.0.1 (continued) Structural diagram of primary reflection type glass plate liquid level gauge (IN4.0) t
Technical requirements
Should comply with HG 21588-95 {Glass Plate Liquid Level Gauge Standard Series and Technical Requirements》.
Selection Regulations
Flange size and type for external connection
The nominal diameter of the flange is DN20 or 3/4\. 5.1.1
5.1.2The flange types are A, B and C, and their connection dimensions are as follows: Type A: Raised face flange (RF), according to HGJ50-91, PN6.3 Type B: Raised face flange (M), according to HGJ 51-91, PN6.3; Type C: Raised face flange (RF), according to ANSIB16.5W.N.300#. 5.2
This standard uses flexible graphite composite gaskets. Users can choose to replace materials with a preload pressure less than or equal to 48.5MPa and a gasket coefficient m less than or equal to 2 according to operating conditions and medium characteristics, but it must be indicated in the assembly drawing of the equipment. 5.3 Marking and specifications
Marking regulations and examples shall comply with the relevant regulations in HG21588-95. 5.3.2 Liquid level gauges of various specifications in this standard shall be selected according to Table 5.3.2 and indicated in the details column of the equipment assembly drawing.
Capsule 5.3.2 Specifications and markings for reflective glass-filled liquid level gauges (PN4.0)
Liquid level gauge A (B, C) R4.0-I -550V(P)
R4.0-1 850V(P)
Liquid level gauge A (B, C)
R4.0-- 1 -1150V(P)
R4.0-I -1450V(P)
Liquid level gauge A (B, C)
R4.0-- 1 -1750V(P)
Liquid level gauge A (BC)
R4.0-I -550V(P)
A(B,C)
Hidden surface meter
R4. 0- 1 -850V(P)
Axillary surface meter
R4. 0-I -1150V(P)
Wind surface meterA(B,C)
Hidden surface meter
A(B,C)
R4. 0— 1 -1450V(P)
Liquid level meter
R4. 0- -1750V(P)
Axillary surface meter
R4.0- I - 550V(P)
R4. 0- IW -- 850V(P)
Quilt surface gauge A(B,C)
R4, 0- 1 W-1150V(P)
Liquid level gauge
R4. 0-1W-1450V(P)
Cross surface gauge A(B,C)
Liquid level gauge A(B,C)
R4, 0- 1 W- 1750V(P)
Liquid level gauge
R4. 0- IW -- 550V(P)
R4. -- I W--850V(P)
Axillary surface gauge
A(B,C)
Liquid level gauge A(B,C)bzxZ.net
R4, 0- Iw-1150V(P)
Quilt surface meter A(B,C)
R4. 0- I W-1450V(P)
Surface meter
R4. 0- I W-1750V(P)
Standard drawing (i.e. construction drawing) drawing number
HG 21590—95-1
HG 21590-95-2
HG 21590-95—3
HG 21590- 95—4
HG 21590- 955
HG 21590-95-6
HG 21590-95-7
HG 21590-95--8
HG 21590- 95 -- 9
HG 21590-95-10
HG 21590—95—11
HG 21590—95—12
HG 21590— 95-13
HG 21590— 95—14
HG 21590—95—15
HG 21590-95-16
HG 21590—95-17
HG 21590-95-18
HG 21590-95—19
HG 21590—95—20
Additional Notes
The unit proposing this standard, the editor-in-chief
and the main drafters
Ministry of Equipment Investment and Technology Center
Global Chemical Engineering Corporation
Main drafters
Wang Xiaohua
Xue Tijun
Kong Xianglin
Bang Pichang
Xu Zhiyuan
Zou Zhiguang
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG/T 21554.1-1995 Saddle ring packing
- GB/T 5211.11-1986 Determination of water-soluble sulfate, chloride and nitrate of pigments
- GB/T 19562-2004 Specification for soybean borer monitoring and investigation
- GB/T 15665-1995 Determination of glycoside hydrocyanic acid content in beans
- GB 16356-1996 Standard for the control of radon and its progeny in underground buildings
- HG/T 2105-1991 Glass-lined equipment slip-on flange
- JB/T 3168.3-1999 Chemical composition analysis method for spray welding alloy powder
- JB/T 9000-1999 General technical requirements for fluid couplings
- GB/T 39551.1-2020 Patent navigation guide—Part 1:General principles
- GB 16808-1997 Technical requirements and test methods for combustible gas alarm controllers
- GB/T 15893.3-1995 Determination of sulfate in industrial circulating cooling water - Gravimetric method
- HG 3040-1988 Guide for the selection, storage, use and maintenance of rubber and plastic hoses and hose assemblies
- NY 620-2002 Multi-gram suspension seed coating agent
- GB/T 16149-1995 Specification for dose estimation of chronic radiation sickness caused by external exposure
- GB/T 4516-1995 Test method for seam thickness of household sewing machines
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com