AS 1657 1992 Fixed platforms, walkways, stairways
固定平台、走道、楼梯和梯子——设计、建造和安装
AS 1657 1992 Fixed platforms, walkways, stairways and ladders - Design, construction and installa
Fixed platforms, walkways, stairways and ladders — Design, construction and installation
标准信息
STANDARD INFORMATION- 标准编号
- AS 1657 1992 Fixed platforms, walkways, stairways
- 所属分类
- AS 澳大利亚标准
- 发布机构
- Standards Australia
- 版本年份
- 1992
- 文件语言
- 英语
- 文件格式
- 文件页数
- 6 页
- 文件大小
- 434.16 KB
中文名称为参考译名,文件语言以原文为准。
· 更新:
标准简介
OVERVIEW中文简介
该标准规定了固定平台、走道、楼梯和梯子的设计、建造和安装要求。它涵盖了结构材料、焊接规范、护栏系统完整性测试以及各类梯子和楼梯的具体尺寸与安全标准。
English summary
This standard specifies the requirements for the design, construction, and installation of fixed platforms, walkways, stairways, and ladders. It covers structural materials, welding specifications, guardrail system integrity testing, and specific dimensional and safety standards for various types of ladders and stairways.
以上为根据文件整理的内容简介。
相关标签
标准内容预览
DOCUMENT PREVIEWAS 1657—1992
Australian Standard®
Fixed platforms, walkways, stairways and ladders — Design, construction and installation
1
AS IS
内部资料
仅供参考
张忠辉惠存
禁止一切非法目的和活动行为,否则后果自负。
NOT FOR PUBLIC RELEASE
2
This Australian Standard was prepared by Committee SF/13, Platforms, Gangways, Stairways and Ladders. It was approved on behalf of the Council of Standards Australia on 9 September 1992 and published on 16 November 1992.
The following interests are represented on Committee SF/13:
Aluminium Development Council
Bureau of Steel Manufacturers of Australia
Confederation of Australian Industry
Department of Employment, Vocational Education, Training and Industrial Relations, Qld
Department of Labour and Industry, Tas.
Master Builders Construction and Housing Association of Australia
Pacific Power
Public Works Department, N.S.W.
Royal Australian Institute of Architects
Water Board, Sydney-Illawarra-Blue Mountains
WorkCover Authority of New South Wales
Review of Australian Standards. To keep abreast of progress in industry, Australian Standards are subject to periodic review and are kept up to date by the issue of amendments or new editions as necessary. It is important therefore that Standards users ensure that they are in possession of the latest edition, and any amendments thereto.
Full details of all Australian Standards and related publications will be found in the Standards Australia Catalogue of Publications; this information is supplemented each month by the magazine 'The Australian Standard', which subscribing members receive, and which gives details of new publications, new editions and amendments, and of withdrawn Standards.
Suggestions for improvements to Australian Standards, addressed to the head office of Standards Australia, are welcomed. Notification of any inaccuracy or ambiguity found in an Australian Standard should be made without delay in order that the matter may be investigated and appropriate action taken.
This Standard was issued in draft form for comment as DR 90065.
3
Australian Standard®
Fixed platforms, walkways, stairways and ladders — Design, construction and installation
First published as AS CA10-1938.
Second edition 1963.
Third edition 1966.
Fourth edition 1971.
Revised and redesignated AS 1657-1974.
Second edition 1985.
Third edition 1992.
PUBLISHED BY STANDARDS AUSTRALIA
(STANDARDS ASSOCIATION OF AUSTRALIA)
1 THE CRESCENT, HOMEBUSH, NSW 2140
ISBN 0 7262 7861 0
4
PREFACE
This Standard was prepared by the Standards Australia Committee on Platforms, Gangways, Stairways and Ladders, to supersede AS 1657-1985.
Changes to the Standard include —
- reducing the minimum wall thickness of steel piping which may be used;
- incorporating a minimum tensile yield stress requirement for aluminium alloys;
- deleting references to specific aluminium alloys and tempers;
- updating the dimensions of steel sections other than piping, to reflect current manufacturing practices; and
- provision of test methods to determine the integrity of guardrail systems, and the strength of the connection between guardrail posts and the supporting structure.
© Copyright — STANDARDS AUSTRALIA
Users of Standards are reminded that copyright subsists in all Standards Australia publications and software. Except where the Copyright Act allows and except where provided for below no publications or software produced by Standards Australia may be reproduced, stored in a retrieval system in any form or transmitted by any means without prior permission in writing from Standards Australia. Permission may be conditional on an appropriate royalty payment. Requests for permission and information on commercial software royalties should be directed to the head office of Standards Australia.
Standards Australia will permit up to 10 percent of the technical content pages of a Standard to be copied for use exclusively in-house by purchasers of the Standard without payment of a royalty or advice to Standards Australia.
Standards Australia will also permit the inclusion of its copyright material in computer software programs for no royalty payment provided such programs are used exclusively in-house by the creators of the programs.
Care should be taken to ensure that material used is from the current edition of the Standard and that it is updated whenever the Standard is amended or revised. The number and date of the Standard should therefore be clearly identified.
The use of material in print form or in computer software programs to be used commercially, with or without payment, or in commercial contracts is subject to the payment of a royalty. This policy may be varied by Standards Australia at any time.
5
CONTENTS
| Page | |
|---|---|
| SECTION 1 SCOPE AND GENERAL | |
| 1.1 SCOPE | 4 |
| 1.2 APPLICATION | 4 |
| 1.3 REFERENCED DOCUMENTS | 4 |
| 1.4 DEFINITIONS | 5 |
| SECTION 2 STRUCTURAL DESIGN, MATERIALS AND WELDING | |
| 2.1 DESIGN | 7 |
| 2.2 MATERIALS | 7 |
| 2.3 WELDING | 8 |
| SECTION 3 PLATFORMS, CONTINUOUS WALKWAYS, AND STEPS WITH LANDINGS | |
| 3.1 GENERAL REQUIREMENTS | 9 |
| 3.2 PROTECTION AT SIDES, ENDS, EDGES, AND OPENINGS | 9 |
| 3.3 DESIGN | 10 |
| 3.4 GUARDRAILING | 10 |
| SECTION 4 STAIRWAYS | |
| 4.1 WIDTH AND ANGLE OF SLOPE | 12 |
| 4.2 FLIGHTS | 12 |
| 4.3 STAIRS | 12 |
| 4.4 LANDINGS | 12 |
| 4.5 GUARDRAILING | 12 |
| 4.6 HANDRAILING | 12 |
| SECTION 5 FIXED LADDERS | |
| 5.1 CLEARANCES | 15 |
| 5.2 ACCESS THROUGH HORIZONTAL OPENINGS | 15 |
| 5.3 LADDER LANDINGS | 15 |
| 5.4 GUARDRAILING | 15 |
| 5.5 STEP LADDERS | 17 |
| 5.6 RUNG LADDERS | 17 |
| 5.7 INDIVIDUAL-RUNG LADDERS (STEP-IRONS) | 21 |
| APPENDICES | |
| A TYPICAL COMPONENT DIMENSIONS AND SPACINGS FOR GUARDRAILING | 26 |
| B TESTING OF GUARDRAIL POSTS | 28 |
| C TESTING OF GUARDRAILS | 29 |
6
预览内容由文件识别整理,表格、公式及文字请以原始文件为准。
原文图片预览
PAGE IMAGES下载标准文件
AS 1657 1992 Fixed platforms, walkways, stairways
英语 · PDF · 6 页 · 434.16 KB