HG 2263-1992 Single-stage cantilever double-acting liquid ring chlorine pump type and basic parameters
time:
2024-08-13 13:37:17
- HG 2263-1992
- Abolished
Standard ID:
HG 2263-1992
Standard Name:
Single-stage cantilever double-acting liquid ring chlorine pump type and basic parameters
Chinese Name:
单级悬臂双作用液环式氯气泵型式与基本参数
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1992-01-08 -
Date of Implementation:
1992-07-01 -
Date of Expiration:
2007-03-01
Standard ICS number:
Chemical Technology>>71.120 Chemical EquipmentChina Standard Classification Number:
>>>>G9 Machinery>>General Machinery and Equipment>>J71 Pump
alternative situation:
Replaced by HG/T 2262-2006

Skip to download
Summary:
HG 2263-1992 Single-stage cantilever double-acting liquid ring chlorine pump type and basic parameters HG2263-1992 standard download decompression password: www.bzxz.net

Some standard content:
Chemical Industry Standard of the People's Republic of China
Single-stage cantilever double-acting liquid ring chlorine pump
Type and basic parameters
1 Subject content and scope of application
HG2263-92
1.1 This standard specifies the type and basic parameters of the YLJ single-stage cantilever double-acting liquid ring chlorine pump (hereinafter referred to as liquid ring pump). 1.2 This standard is applicable to liquid ring pumps for chlorine with a purity of not less than 90%, a water content of not more than 0.6%, and an inlet temperature of not more than 40°C. The circulating liquid is 98% concentrated sulfuric acid with a pump temperature of not more than 30°C. 2. Reference standards
HG2101 Single-stage cantilever double-acting liquid ring chlorine pump test and parameter measurement method 3 Liquid ring pump performance requirements and performance range 3.1. Performance requirements
The performance parameter values of liquid ring pumps are greatly affected by the medium and other working conditions. The performance parameters measured during production and testing must be converted to the same benchmark, which is the specified conditions for the performance of the liquid ring pump. 3.1.1 Medium conditions
Air is the specified gas medium, and clean water is the specified circulating liquid. 3.1.2 Inlet conditions
a. Inlet pressure
0.101MPa (absolute pressure);
b. Inlet temperature
c. Relative humidity
3.1.3 Inlet water temperature
3.1.4 The speed should comply with the provisions of Table 1,
3.2 Performance range
Rated gas volume 150~750m/h;
Rated pressure 0.15MPa.
4 Type
4.1 The liquid ring pump is a cantilever diameter Double-acting structure for air intake and exhaust. 4.2 The liquid ring pump is connected to the drive motor through an elastic coupling. 4.3 From the pump end, the impeller rotates counterclockwise. 5 Mark
5.1 YLJ: indicates the type code of the liquid ring pump. Approved by the Ministry of Chemical Industry of the People's Republic of China on January 8, 1992. 10
Implemented on July 1, 1992
HG226392
5.2 The number after the dash: The numerator indicates the rated value of the liquid ring pump. Rated gas volume, m2/h, the denominator represents the maximum exhaust pressure of the liquid ring pump, MPa.
5.3 Marking example:
YLI-750/0.3
Maximum exhaust pressure of liquid ring pump, MPa:bzxz.net
Rated gas volume of liquid ring pump, m2/h;
Type code of liquid ring pump
6 Basic parameters
6.1 The basic parameters of the liquid ring pump shall comply with the provisions of Table 1 Table 1 Single-stage cantilever double-acting liquid ring pump series| |tt||Rated outlet pressure
YLJ-150/0.25
YLJ-300/0.3
YLJ-500/0.3
YLJ--750/0.3
(0.15MPa)
Suitable working
Force range
Maximum exhaust
Gas pressure
Note: 1) Specific weight refers to the ratio of the weight of the pump and the base to the rated gas volume. 6.2 Table 1 lists the performance under the conditions specified in Article 3.1. Isothermal
Specific weight》
kg/m°/h
Electric motor
Suction and exhaust
Outlet diameter
6.3 The exhaust pressure of the liquid ring pump is expressed by the pressure at the pump outlet, in MPa. 6.4 The gas volume under the rated outlet pressure of the liquid ring pump refers to the gas volume passing through the pump inlet per unit time when the outlet of the liquid ring pump is the rated pressure and the inlet is 0.101MPa (absolute pressure), in m\/h. 6.5 The performance deviation of the liquid ring pump shall comply with the provisions of HG2101. Additional notes:
This standard was proposed by China Chemical Equipment Corporation and is under the jurisdiction of the Chemical Industry Ministry's Chemical Machinery Equipment Standardization Technical Unit (Chemical Industry Ministry Chemical Machinery Research Institute). This standard was drafted by Jinxi Chemical Machinery Factory and the main drafter of this standard was Pan Jixian.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Single-stage cantilever double-acting liquid ring chlorine pump
Type and basic parameters
1 Subject content and scope of application
HG2263-92
1.1 This standard specifies the type and basic parameters of the YLJ single-stage cantilever double-acting liquid ring chlorine pump (hereinafter referred to as liquid ring pump). 1.2 This standard is applicable to liquid ring pumps for chlorine with a purity of not less than 90%, a water content of not more than 0.6%, and an inlet temperature of not more than 40°C. The circulating liquid is 98% concentrated sulfuric acid with a pump temperature of not more than 30°C. 2. Reference standards
HG2101 Single-stage cantilever double-acting liquid ring chlorine pump test and parameter measurement method 3 Liquid ring pump performance requirements and performance range 3.1. Performance requirements
The performance parameter values of liquid ring pumps are greatly affected by the medium and other working conditions. The performance parameters measured during production and testing must be converted to the same benchmark, which is the specified conditions for the performance of the liquid ring pump. 3.1.1 Medium conditions
Air is the specified gas medium, and clean water is the specified circulating liquid. 3.1.2 Inlet conditions
a. Inlet pressure
0.101MPa (absolute pressure);
b. Inlet temperature
c. Relative humidity
3.1.3 Inlet water temperature
3.1.4 The speed should comply with the provisions of Table 1,
3.2 Performance range
Rated gas volume 150~750m/h;
Rated pressure 0.15MPa.
4 Type
4.1 The liquid ring pump is a cantilever diameter Double-acting structure for air intake and exhaust. 4.2 The liquid ring pump is connected to the drive motor through an elastic coupling. 4.3 From the pump end, the impeller rotates counterclockwise. 5 Mark
5.1 YLJ: indicates the type code of the liquid ring pump. Approved by the Ministry of Chemical Industry of the People's Republic of China on January 8, 1992. 10
Implemented on July 1, 1992
HG226392
5.2 The number after the dash: The numerator indicates the rated value of the liquid ring pump. Rated gas volume, m2/h, the denominator represents the maximum exhaust pressure of the liquid ring pump, MPa.
5.3 Marking example:
YLI-750/0.3
Maximum exhaust pressure of liquid ring pump, MPa:bzxz.net
Rated gas volume of liquid ring pump, m2/h;
Type code of liquid ring pump
6 Basic parameters
6.1 The basic parameters of the liquid ring pump shall comply with the provisions of Table 1 Table 1 Single-stage cantilever double-acting liquid ring pump series| |tt||Rated outlet pressure
YLJ-150/0.25
YLJ-300/0.3
YLJ-500/0.3
YLJ--750/0.3
(0.15MPa)
Suitable working
Force range
Maximum exhaust
Gas pressure
Note: 1) Specific weight refers to the ratio of the weight of the pump and the base to the rated gas volume. 6.2 Table 1 lists the performance under the conditions specified in Article 3.1. Isothermal
Specific weight》
kg/m°/h
Electric motor
Suction and exhaust
Outlet diameter
6.3 The exhaust pressure of the liquid ring pump is expressed by the pressure at the pump outlet, in MPa. 6.4 The gas volume under the rated outlet pressure of the liquid ring pump refers to the gas volume passing through the pump inlet per unit time when the outlet of the liquid ring pump is the rated pressure and the inlet is 0.101MPa (absolute pressure), in m\/h. 6.5 The performance deviation of the liquid ring pump shall comply with the provisions of HG2101. Additional notes:
This standard was proposed by China Chemical Equipment Corporation and is under the jurisdiction of the Chemical Industry Ministry's Chemical Machinery Equipment Standardization Technical Unit (Chemical Industry Ministry Chemical Machinery Research Institute). This standard was drafted by Jinxi Chemical Machinery Factory and the main drafter of this standard was Pan Jixian.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 8486-1987 Inspection rules for hollow steel screen doors and windows GB8486-87
- SY/T 6520-2001 Test method for crude oil dehydration - Pressure autoclave method
- GB/T 8231-2007 Sorghum
- MT/T 920-2002 Type and parameters of special battery-type rubber-shrouded wheel motors for explosion-proof coal mines
- GB/T 3290-1982 Dimensions and properties of magnetic tape reels for information exchange
- JB/T 7146.1-1993 Carburetor valve needle profile
- JB/T 5870-1991 Technical requirements for YZR series medium-sized high-voltage wound rotor three-phase asynchronous motors for hoisting and metallurgy
- GB/T 8802-2001 Determination of Vicat softening temperature of thermoplastic pipes and fittings
- GB/T 5401-1985 Determination of alkali solubility of pulp
- JB/T 6753.5-1993 Electrical equipment - Equipment component tolerances - Assembly structure general tolerances
- JB/T 2001.38-1999 Water system filling valve relay (Type A) (PN=20MPa)
- GB 1523-1993 Sheep wool
- JB/T 7213-1994 Horizontal bottle conveyor
- GB/T 22234-2008 Labelling of chemicals based on GHS
- GB/T 11606.10-1989 Environmental test methods for analytical instruments - Air pressure test
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com