GB/T 15057.11-1994 Determination of particle size of limestone for chemical industry
time:
2024-08-09 02:16:47
- GB/T 15057.11-1994
- in force
Standard ID:
GB/T 15057.11-1994
Standard Name:
Determination of particle size of limestone for chemical industry
Chinese Name:
化工用石灰石粒度的测定
Standard category:
National Standard (GB)
-
Date of Release:
1994-05-05 -
Date of Implementation:
1995-02-01
Standard ICS number:
Mining and mineral products >> 73.080 Non-metallic mineralsChina Standard Classification Number:
Mining>>Non-metallic Minerals>>D53 Building Materials Raw Materials
Release date:
1994-05-05Review date:
2004-10-14Drafter:
Li Donghao, Xu XiulanDrafting Organization:
Chemical Industry Mine Design Institute, Ministry of Chemical IndustryFocal point Organization:
China Petroleum and Chemical Industry AssociationProposing Organization:
Ministry of Chemical Industry of the People's Republic of ChinaPublishing Department:
China Petroleum and Chemical Industry AssociationCompetent Authority:
China Petroleum and Chemical Industry Association
Skip to download
Summary:
GB/T 15057.11-1994 Determination of particle size of limestone for chemical industry GB/T15057.11-1994 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Determination of particle size of limestone for chemical industry,
Limestone for chemical industry-Determination of size
1 Content and scope of application
This standard specifies the method of determining particle size by sieving method. This standard is applicable to the determination of particle size of bulk limestone for chemical industry. 2 Reference standards
GB6003 Test sieve
GB/T15057.1 Sampling and sample preparation method of limestone for chemical industry 3 Summary of method
The percentage of a certain particle size is estimated by visual method. The mass of the sample on or under the sieve is determined by sieving method, and the percentage is calculated. 4 Instruments
4.1 Bench scale (GB335).
4.2 Test sieve: prepared in accordance with GB6003.
150mm sieve: sieve surface thickness 1.5mm, round sieve hole. GB/T15057.11—94
50mm sieve: The effective size of the sieve surface is 500mm×1000mm, the sieve hole is round, and the height of the sieve frame is based on the ore not splashing out during screening. 5 Sampling
The samples used for particle size determination should be taken separately from the ore pile and the belt conveyor. The sampling method is in accordance with GB/T15057.1 Sampling and sample preparation method for limestone for chemical industry. The point and row spacing of the ore pile should be relaxed in proportion, and the belt conveyor should take the entire cross section. The amount of the sample is increased, and the total amount of sampling shall not be less than 500kg.
6 Determination method
The determination of this particle size takes 50~150mm as an example. The other particle size determination methods are the same, only the sieve holes of the corresponding test sieve are changed. 6.1 Visual method
According to the technical index requirements, a batch of products is directly estimated by visual method to measure the percentage of particle sizes less than 50 and greater than 150mm. If there is any objection to the result of the visual method, the sieving method shall be used for determination. 6.2 Sieving method
6.2.1 Determination method of particle size greater than 150mm Weigh all collected samples, take out the ore that may be greater than 150mm in particle size, put it into a 150mm metal circular sieve hole at any angle, and weigh the amount of the material on the sieve. The percentage of particle size greater than 150mm (cz) is calculated according to formula (1): Approved by the State Administration of Technical Supervision on May 5, 1994 214bZxz.net
Formula
Implementation on February 1, 1995
GB/T15057.11--94
-Mass of particle size greater than 150mm, kg;
Where: m—
m—Mass of sample, kg.
6.2.2 Determination of particle size less than 50 mm
Sieve the ore less than 150 mm in 6.2.1 in batches. The mesh size is 50 mm and round. Sieve 20 kg each time. Spread the ore on the sieve surface and sieve horizontally for 1 min. The amplitude is about 0.5 m and the number of times is 15. After all samples are sieved, weigh the amount of the sieve. The percentage of particles less than 50 mm (z) is calculated according to formula (2):
Where: mz——the mass of particles less than 50 mm, kg, m
the mass of a sample, kg.
Additional remarks:
This standard is proposed by the Ministry of Chemical Industry of the People's Republic of China. This standard is under the jurisdiction of the Chemical Industry Mining Design and Research Institute of the Ministry of Chemical Industry. m2
This standard was drafted by the Chemical Industry Mining Design and Research Institute of the Ministry of Chemical Industry. The main drafters of this standard are Li Donghao and Xu Xiulan. Standards Authorization Search Network
Various Standards Industries
Years of Fees for Standardization
(2)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Determination of particle size of limestone for chemical industry,
Limestone for chemical industry-Determination of size
1 Content and scope of application
This standard specifies the method of determining particle size by sieving method. This standard is applicable to the determination of particle size of bulk limestone for chemical industry. 2 Reference standards
GB6003 Test sieve
GB/T15057.1 Sampling and sample preparation method of limestone for chemical industry 3 Summary of method
The percentage of a certain particle size is estimated by visual method. The mass of the sample on or under the sieve is determined by sieving method, and the percentage is calculated. 4 Instruments
4.1 Bench scale (GB335).
4.2 Test sieve: prepared in accordance with GB6003.
150mm sieve: sieve surface thickness 1.5mm, round sieve hole. GB/T15057.11—94
50mm sieve: The effective size of the sieve surface is 500mm×1000mm, the sieve hole is round, and the height of the sieve frame is based on the ore not splashing out during screening. 5 Sampling
The samples used for particle size determination should be taken separately from the ore pile and the belt conveyor. The sampling method is in accordance with GB/T15057.1 Sampling and sample preparation method for limestone for chemical industry. The point and row spacing of the ore pile should be relaxed in proportion, and the belt conveyor should take the entire cross section. The amount of the sample is increased, and the total amount of sampling shall not be less than 500kg.
6 Determination method
The determination of this particle size takes 50~150mm as an example. The other particle size determination methods are the same, only the sieve holes of the corresponding test sieve are changed. 6.1 Visual method
According to the technical index requirements, a batch of products is directly estimated by visual method to measure the percentage of particle sizes less than 50 and greater than 150mm. If there is any objection to the result of the visual method, the sieving method shall be used for determination. 6.2 Sieving method
6.2.1 Determination method of particle size greater than 150mm Weigh all collected samples, take out the ore that may be greater than 150mm in particle size, put it into a 150mm metal circular sieve hole at any angle, and weigh the amount of the material on the sieve. The percentage of particle size greater than 150mm (cz) is calculated according to formula (1): Approved by the State Administration of Technical Supervision on May 5, 1994 214bZxz.net
Formula
Implementation on February 1, 1995
GB/T15057.11--94
-Mass of particle size greater than 150mm, kg;
Where: m—
m—Mass of sample, kg.
6.2.2 Determination of particle size less than 50 mm
Sieve the ore less than 150 mm in 6.2.1 in batches. The mesh size is 50 mm and round. Sieve 20 kg each time. Spread the ore on the sieve surface and sieve horizontally for 1 min. The amplitude is about 0.5 m and the number of times is 15. After all samples are sieved, weigh the amount of the sieve. The percentage of particles less than 50 mm (z) is calculated according to formula (2):
Where: mz——the mass of particles less than 50 mm, kg, m
the mass of a sample, kg.
Additional remarks:
This standard is proposed by the Ministry of Chemical Industry of the People's Republic of China. This standard is under the jurisdiction of the Chemical Industry Mining Design and Research Institute of the Ministry of Chemical Industry. m2
This standard was drafted by the Chemical Industry Mining Design and Research Institute of the Ministry of Chemical Industry. The main drafters of this standard are Li Donghao and Xu Xiulan. Standards Authorization Search Network
Various Standards Industries
Years of Fees for Standardization
(2)
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 5094.2-2003 Industrial systems, devices and equipment and industrial products - Structural principles and reference codes Part 2: Classification and classification codes of items
- JB/T 50160-1999 Energy consumption classification of oxygen stations
- JB/T 8028.1-1999 Low legs for machine tool fixture parts and components
- GB/T 5413.3-1997 Determination of fat in infant formula and milk powder
- SY/T 0062-2000 Standard test method for penetration resistance of pipeline coatings(Blunt rod)
- GB/T 4634-1996 Determination of potassium, sodium, iron, calcium, magnesium and manganese in coal ash (atomic absorption spectrophotometry)
- JB/T 3108-1999 Single-spindle woodworking milling machine parameters
- GB 15322.5-2003 Combustible gas detectors Part 5: Independent combustible gas detectors for measuring artificial gas
- JB/T 3411.102-1999 7:24 Dimensions of long intermediate sleeves for cone/Morse cone
- JJG 1024-2007 Verification Regulation of Pulse Power Meters
- GB/T 15652-1995 General specification for metal oxide semiconductor gas sensors
- GB 50207-1994 Technical specification for roofing engineering
- GB/T 15515-1995 光功率计技术条件
- JB/T 3073.1-1991 Technical specifications for die-forged moving and stationary blades and hot-rolled stationary blade blanks for steam turbines Die-forged stationary blade blanks
- NY/T 2550-2014 Determination of aflatoxin B1 in feed - Colloidal gold method
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com