GB 16220-1996 Hygienic standard for Beauveria bassiana spores in workshop air
time:
2024-08-06 06:34:06
- GB 16220-1996
- in force
Standard ID:
GB 16220-1996
Standard Name:
Hygienic standard for Beauveria bassiana spores in workshop air
Chinese Name:
车间空气中白僵菌孢子卫生标准
Standard category:
National Standard (GB)
-
Date of Release:
1996-04-03 -
Date of Implementation:
1996-09-01
Standard ICS number:
Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplaceChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
Release date:
1996-04-03Review date:
2004-10-14Drafting Organization:
Jilin Provincial Institute of Labor Health and Occupational Disease Prevention and ControlFocal point Organization:
Ministry of HealthPublishing Department:
State Administration of Technical Supervision Ministry of Health of the People's Republic of ChinaCompetent Authority:
Ministry of Health
Skip to download
Summary:
This standard specifies the maximum permissible concentration of Beauveria bassiana spores in the air of workshops and its monitoring and testing methods. This standard is applicable to enterprises, agricultural and forestry units that produce and use Beauveria bassiana spores. GB 16220-1996 Hygienic standard for Beauveria bassiana spores in the air of workshops GB16220-1996 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Health standard for beauveria bassianain the air of workplace
Subject content and scope of application
This standard specifies the maximum permissible concentration of Beauveria bassiana in the air of workplace and its monitoring and inspection methods. This standard applies to enterprises, agriculture and forestry units that produce and use Beauveria bassiana spores. 2 Hygiene requirements
The maximum permissible concentration of Beauveria bassiana in the air of workplace is 6×10° spores/m. 3
Monitoring and inspection methods
Concentration counting method of Beauveria bassiana spores in workplace air. See Appendix A (Supplement). Approved by the State Administration of Technical Supervision on April 3, 1996, GB16220-1996
Implementation on September 1, 1996
A1 Principle
GB162201996
Appendix A
Method for determining the number of Beauveria bassiana spores in workshop air (supplement)
After sampling and weighing with a dust filter, dissolve the filter with butyl acetate to form a suspension of Beauveria bassiana spores, count them under a microscope with a blood cell counting plate, and then convert them into the concentration of Beauveria bassiana spores in the air (number of spores/m\). A2 Equipment and reagents
Dust sampler; dust filter; analytical balance with a sensitivity of not less than 0.1mg, microscope; blood cell counting plate; glass rod; small beaker; butyl acetate.
A3 Procedure for determining the number of Beauveria bassiana spores
A3.1 Sampling: Use a dust sampler equipped with a dust filter to extract air at a flow rate of 1020L/min. A3.2 Preparation of bacterial solution: Place the filter membrane for collecting Beauveria bassiana spores in a small beaker, add 1-2mL of butyl acetate with a pipette, and stir thoroughly with a glass rod to make a uniform suspension of Beauveria bassiana. Then dilute it in proportion to the number of milligrams of weight gain of the filter membrane to form a mg/mL dilution. A3.3 Filling the counting pool: Place the blood cell counting plate flat on the table, place the cover glass close to the scale of the blood cell counting plate, dip the bacterial solution with a glass rod, and let it penetrate into the counting plate grid from the grooves on the front and back edges of the cover glass, absorb the bacterial solution in the grooves with filter paper, let it stand for a while, and count under a microscope. If bubbles form on the blood cell counting plate, the pool should be refilled. A3.4 Microscope counting: Counting can be performed using a 600x microscope. Count the spores in the five middle grids of a 25mm×16mm blood cell counting plate, that is, the number of spores in the four corners and the middle grid (a total of 80 small grids). For spores pressed on the double lines at the edge of the grid, count the top but not the bottom, count the left but not the right. To obtain an accurate spore count, the average of the five middle grids under the microscope should not exceed 100 at the highest and should not be less than 10 at the lowest.
A4 Calculation of the number of Beauveria bassiana spores
Where: m--the number of Beauveria bassiana spores per cubic meter of air; n--the average number of spores in 5 middle grids multiplied by 25, that is, the number of spores in 0.1mm2, pcs. k-the volume of the 0.2~0.5mg/mL concentration bacterial solution, mL. Q sampling flow rate, L/min,
t—sampling time, min;
100.1mm2 converted to 1cm3 and air L converted to m2. ·(Al)
Example: When the sampling flow rate is 20L/min and the sampling time is 5min, the filter membrane weight gain is 3.7mg, dissolved in 18.5ml solvent. If the average number of spores in the 5 middle grids of the counting plate is 83.3, try to calculate the number of spores/m. Substitute the above data into the formula:
83. 3 X25×18. 5×10*
20 X 5
=3.8×10° Number of spores/m3
That is, the number of spores per cubic meter is 3.8 billion.
Additional instructions: Www.bzxZ.net
This standard is proposed by the Ministry of Health of the People's Republic of China. GB16220-1996
This standard was drafted by Jilin Provincial Institute of Labor Hygiene and Occupational Disease Prevention and Control and Anhui Provincial Institute of Labor Hygiene and Occupational Disease Prevention and Control. The main drafters of this standard are Zhao Zichen and Wang Hongbo. This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases of the Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Health standard for beauveria bassianain the air of workplace
Subject content and scope of application
This standard specifies the maximum permissible concentration of Beauveria bassiana in the air of workplace and its monitoring and inspection methods. This standard applies to enterprises, agriculture and forestry units that produce and use Beauveria bassiana spores. 2 Hygiene requirements
The maximum permissible concentration of Beauveria bassiana in the air of workplace is 6×10° spores/m. 3
Monitoring and inspection methods
Concentration counting method of Beauveria bassiana spores in workplace air. See Appendix A (Supplement). Approved by the State Administration of Technical Supervision on April 3, 1996, GB16220-1996
Implementation on September 1, 1996
A1 Principle
GB162201996
Appendix A
Method for determining the number of Beauveria bassiana spores in workshop air (supplement)
After sampling and weighing with a dust filter, dissolve the filter with butyl acetate to form a suspension of Beauveria bassiana spores, count them under a microscope with a blood cell counting plate, and then convert them into the concentration of Beauveria bassiana spores in the air (number of spores/m\). A2 Equipment and reagents
Dust sampler; dust filter; analytical balance with a sensitivity of not less than 0.1mg, microscope; blood cell counting plate; glass rod; small beaker; butyl acetate.
A3 Procedure for determining the number of Beauveria bassiana spores
A3.1 Sampling: Use a dust sampler equipped with a dust filter to extract air at a flow rate of 1020L/min. A3.2 Preparation of bacterial solution: Place the filter membrane for collecting Beauveria bassiana spores in a small beaker, add 1-2mL of butyl acetate with a pipette, and stir thoroughly with a glass rod to make a uniform suspension of Beauveria bassiana. Then dilute it in proportion to the number of milligrams of weight gain of the filter membrane to form a mg/mL dilution. A3.3 Filling the counting pool: Place the blood cell counting plate flat on the table, place the cover glass close to the scale of the blood cell counting plate, dip the bacterial solution with a glass rod, and let it penetrate into the counting plate grid from the grooves on the front and back edges of the cover glass, absorb the bacterial solution in the grooves with filter paper, let it stand for a while, and count under a microscope. If bubbles form on the blood cell counting plate, the pool should be refilled. A3.4 Microscope counting: Counting can be performed using a 600x microscope. Count the spores in the five middle grids of a 25mm×16mm blood cell counting plate, that is, the number of spores in the four corners and the middle grid (a total of 80 small grids). For spores pressed on the double lines at the edge of the grid, count the top but not the bottom, count the left but not the right. To obtain an accurate spore count, the average of the five middle grids under the microscope should not exceed 100 at the highest and should not be less than 10 at the lowest.
A4 Calculation of the number of Beauveria bassiana spores
Where: m--the number of Beauveria bassiana spores per cubic meter of air; n--the average number of spores in 5 middle grids multiplied by 25, that is, the number of spores in 0.1mm2, pcs. k-the volume of the 0.2~0.5mg/mL concentration bacterial solution, mL. Q sampling flow rate, L/min,
t—sampling time, min;
100.1mm2 converted to 1cm3 and air L converted to m2. ·(Al)
Example: When the sampling flow rate is 20L/min and the sampling time is 5min, the filter membrane weight gain is 3.7mg, dissolved in 18.5ml solvent. If the average number of spores in the 5 middle grids of the counting plate is 83.3, try to calculate the number of spores/m. Substitute the above data into the formula:
83. 3 X25×18. 5×10*
20 X 5
=3.8×10° Number of spores/m3
That is, the number of spores per cubic meter is 3.8 billion.
Additional instructions: Www.bzxZ.net
This standard is proposed by the Ministry of Health of the People's Republic of China. GB16220-1996
This standard was drafted by Jilin Provincial Institute of Labor Hygiene and Occupational Disease Prevention and Control and Anhui Provincial Institute of Labor Hygiene and Occupational Disease Prevention and Control. The main drafters of this standard are Zhao Zichen and Wang Hongbo. This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases of the Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB 1952.2-2004 Spring mattress for soft furniture
- JB/T 5992.2-1992 Classification and code casting of mechanical manufacturing process methods
- JB/T 9146-1999 Rectangular spline machining allowance and tolerance
- GB/T 4728.3-1998 Graphical symbols for electrical schematics Part 3 Conductors and connectors
- JB/T 8064.1-1996 Technical requirements for compression gas springs
- JB/T 7776.5-1995 Chemical analysis method for silver cadmium oxide electrical contact materials
- GB 4706.3-1986 Safety of household and similar electrical appliances Special requirements for food mixers and similar electrical appliances
- GBZ 39-2002 Diagnostic criteria for occupational acute 1,2-dichloroethane poisoning
- GB/T 11798.2-2001 Technical requirements for the verification of motor vehicle safety testing equipment Part 2: Technical requirements for the verification of roller reaction brake test benches
- JB/T 8375-1996 Technical requirements for induction synchronizer digital display
- CB/T 3944-2002 Flange Stainless Steel Check Valve
- MT/T 516.2-1995 Drill bits for hydraulic rock drills in coal mines
- JB/T 10362-2002 Digital Camera
- MT/T 651-1997 Test method and judgment rules for water cleaning performance of coal jigging machine
- GB/T 5580-2001 Electric drill
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com