Rontgen and Coulomb per kilogram conversion tables
time:
2024-08-04 22:07:35
- GB/T 5116-1985
- Abolished
Standard ID:
GB/T 5116-1985
Standard Name:
Rontgen and Coulomb per kilogram conversion tables
Chinese Name:
伦琴与库仑每千克的相互换算表
Standard category:
National Standard (GB)
-
Date of Release:
1985-04-24 -
Date of Implementation:
1985-01-02 -
Date of Expiration:
2005-10-14
Standard ICS number:
01.060.10China Standard Classification Number:
General>>Measurement>>A51 Quantity and Unit
Release date:
1985-04-24Review date:
2004-10-14Drafting Organization:
National Technical Committee for Quantity and Unit StandardizationFocal point Organization:
National Technical Committee for Standardization of Quantities and UnitsPublishing Department:
National Standardization AdministrationCompetent Authority:
National Standardization Administration
Skip to download
Summary:
GB/T 5116-1985 Conversion table between roentgen and coulomb per kilogram GB/T5116-1985 standard download decompression password: www.bzxz.net
Some standard content:
1 Introduction
National Standard of the People's Republic of China
Rintgen and Coulomb per kilog ram conversion tables UDC 531.78.081
GB 5116—85
1.1 In order to make all national standards gradually adopt the international system of units, according to the actual situation in my country and the needs of various industries, with reference to 15 national standards on relevant quantities and units (GB3100—82, GR3101--82, GB3102.1~3102.13—82), in accordance with GB1.1-81 "General provisions for the preparation of standards in the guidelines for standardization work", GB5116-85 "Rintgen and Coulomb per kilogram conversion tables" are specially compiled.
1.2 This standard applies to all occasions where roentgen (R) is converted into coulomb per dry gram (C/kg) and coulomb per kilogram is converted into roentgen. The conversion in this standard is limited to the conversion required in general. The converted figures in the conversion table are rounded to four significant figures. When the relative uncertainty is required to be less than 5/1000, the conversion factor given should be used for calculation and rounding. The rounding rules are in accordance with the provisions of Appendix C of GB1.1-81. However, due to the limitations of existing experimental technology, the current uncertainty level can only give 3 significant figures. The fourth significant figure given in this standard can only be used as a reference number. The higher significant figures cannot be obtained in actual measurement. 1.3 Exposure is defined as:
When all the charges (positrons and electrons) of the X or Y radiation released in the air of mass dm are blocked by the air, the absolute value dQ of the total charge of a symbol generated in the air is divided by dm. X=dQ/dm.
Note that this quantity does not include the ionization produced by the absorption of the secondary electrons emitted by the mass of air per meter. The SI unit name of irradiation is coulomb per gram, with the symbol C/kg. The non-SI unit temporarily allowed to be used in conjunction with the SI is roentgen, with the symbol. 1.4 Conversion coefficient
The International Conference of Measurement and Measurement Personnel (CGPM), the International Organization for Standardization (ISO) and the International Commission on Radiation Units and Measurements (ICRU) have determined the conversion relationship between roentgen and coulomb per dry gram as follows: 1 R - 2.58 × 10 1 C/kg (accurate value) 1 C/kg = 2.58
×10-4R
1.5 When using the conversion table, it is permitted to multiply (or divide) both the numbers before and after the conversion by the same multiple. For example, how many C/k is equivalent to 3.95R?
First, from Table 1, we can get 395R = 1019 × 10-C/kg, and then divide both by 100 to get: 3.95R: 1.019 × 10-/kg
1.6 In the case of the irradiation base rate, the non-conversion table can also be used. In this case, Table 1 becomes a conversion table from R/s to A/kR (= C/kg·s), and Table 2 becomes a conversion table from A/kg (= (/kg·s) to R/s. 2 Conversion table
National Bureau of Standards 1985.0424 issued
1985-12-01 implementation
C/kg (x 10Www.bzxZ.net
GB5116—85
Conversion table from roentgen to coulomb per gram
R-2.58×1u-4C/kg
GB 5116
Continued Table 1
132 meters
C/kg (× 10~l)
R(×10*)
GB 5116 -85
Continued Table 1
243 days
Conversion table of coulomb per dry gram to roentgen
1C/kg -
143 months
GB5116—85
Continued Table 2
16:4Gi
1578,5
R(×10)
GB 511685
Continued Table 2
February 26
R(×ins)
Additional Notes:
GB 5116—B5
Continued Table 2
This standard was proposed and approved by the National Technical Committee for Standardization of Quantities and Units. The chief author: Du Shihua, the deputy chief author: Chen Mingshao. This standard was proposed by the sixth subcommittee of the committee, whose members are as follows: Chairman: Shi Yuanming, committee members: Zhang Jimin, Yi Ze: Zhen Fucun, Li Shude. Committee members (in order of strokes of surnames): Lu Xiting, Dui Mai, Lv Weichun, Chen Jian, Chen Lishu, Chen Mingai, Xu Mian.
The main drafters of this standard are Liu Danjin and Chen Weixin.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
Rintgen and Coulomb per kilog ram conversion tables UDC 531.78.081
GB 5116—85
1.1 In order to make all national standards gradually adopt the international system of units, according to the actual situation in my country and the needs of various industries, with reference to 15 national standards on relevant quantities and units (GB3100—82, GR3101--82, GB3102.1~3102.13—82), in accordance with GB1.1-81 "General provisions for the preparation of standards in the guidelines for standardization work", GB5116-85 "Rintgen and Coulomb per kilogram conversion tables" are specially compiled.
1.2 This standard applies to all occasions where roentgen (R) is converted into coulomb per dry gram (C/kg) and coulomb per kilogram is converted into roentgen. The conversion in this standard is limited to the conversion required in general. The converted figures in the conversion table are rounded to four significant figures. When the relative uncertainty is required to be less than 5/1000, the conversion factor given should be used for calculation and rounding. The rounding rules are in accordance with the provisions of Appendix C of GB1.1-81. However, due to the limitations of existing experimental technology, the current uncertainty level can only give 3 significant figures. The fourth significant figure given in this standard can only be used as a reference number. The higher significant figures cannot be obtained in actual measurement. 1.3 Exposure is defined as:
When all the charges (positrons and electrons) of the X or Y radiation released in the air of mass dm are blocked by the air, the absolute value dQ of the total charge of a symbol generated in the air is divided by dm. X=dQ/dm.
Note that this quantity does not include the ionization produced by the absorption of the secondary electrons emitted by the mass of air per meter. The SI unit name of irradiation is coulomb per gram, with the symbol C/kg. The non-SI unit temporarily allowed to be used in conjunction with the SI is roentgen, with the symbol. 1.4 Conversion coefficient
The International Conference of Measurement and Measurement Personnel (CGPM), the International Organization for Standardization (ISO) and the International Commission on Radiation Units and Measurements (ICRU) have determined the conversion relationship between roentgen and coulomb per dry gram as follows: 1 R - 2.58 × 10 1 C/kg (accurate value) 1 C/kg = 2.58
×10-4R
1.5 When using the conversion table, it is permitted to multiply (or divide) both the numbers before and after the conversion by the same multiple. For example, how many C/k is equivalent to 3.95R?
First, from Table 1, we can get 395R = 1019 × 10-C/kg, and then divide both by 100 to get: 3.95R: 1.019 × 10-/kg
1.6 In the case of the irradiation base rate, the non-conversion table can also be used. In this case, Table 1 becomes a conversion table from R/s to A/kR (= C/kg·s), and Table 2 becomes a conversion table from A/kg (= (/kg·s) to R/s. 2 Conversion table
National Bureau of Standards 1985.0424 issued
1985-12-01 implementation
C/kg (x 10Www.bzxZ.net
GB5116—85
Conversion table from roentgen to coulomb per gram
R-2.58×1u-4C/kg
GB 5116
Continued Table 1
132 meters
C/kg (× 10~l)
R(×10*)
GB 5116 -85
Continued Table 1
243 days
Conversion table of coulomb per dry gram to roentgen
1C/kg -
143 months
GB5116—85
Continued Table 2
16:4Gi
1578,5
R(×10)
GB 511685
Continued Table 2
February 26
R(×ins)
Additional Notes:
GB 5116—B5
Continued Table 2
This standard was proposed and approved by the National Technical Committee for Standardization of Quantities and Units. The chief author: Du Shihua, the deputy chief author: Chen Mingshao. This standard was proposed by the sixth subcommittee of the committee, whose members are as follows: Chairman: Shi Yuanming, committee members: Zhang Jimin, Yi Ze: Zhen Fucun, Li Shude. Committee members (in order of strokes of surnames): Lu Xiting, Dui Mai, Lv Weichun, Chen Jian, Chen Lishu, Chen Mingai, Xu Mian.
The main drafters of this standard are Liu Danjin and Chen Weixin.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 11416-2002 Daily insulation containers
- JB/T 9199-1999 Technical requirements for anti-seepage coatings
- GB/T 3749.1-1983 Compression-type bulkhead right-angle pipe joint
- GB/T 4199-2003 Definition of rolling bearing tolerances
- GB/T 4699.7-1988 Chemical analysis methods for silicon-chromium alloys - Combustion neutralization titration method for determination of sulfur content
- NY/T 5208-2004 Technical specification for the production of pollution-free food peas
- GB/T 15072.4-1994 Chemical analysis methods for precious metals and their alloys Determination of palladium content in palladium and silver alloys
- GB 15703-1995 Basic technical requirements for flameproof motors
- JB/T 3790.3-1994 Hydraulic automatic strapping machine
- JB/T 6381.1-1992 Cone seal welding pipe joint
- JB/T 8145.1-1995 Cables (wires) for railway rolling stock with AC rated voltage of 3kV and below Natural styrene-butadiene rubber insulated cables (wires) for railway rolling stock
- SC/T 1058-2002 Technical specification for transplantation and proliferation of whitebait Taihu new whitebait transplantation and proliferation technology
- GB/T 16929-1997 Test method for oil transmission rate of packaging material
- JB/T 10353.1-2002 Technical requirements for flameproof motors for fuel dispensers Part 1: YBJY series flameproof three-phase asynchronous motors for fuel dispensers (frame sizes 63 to 100)
- JB/T 1692-1991 Umbrella Handwheel
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com