SY/T 5378-1991 Technical requirements for drilling fluid sand content tester
time:
2024-08-06 20:33:28
- SY/T 5378-1991
- in force
Standard ID:
SY/T 5378-1991
Standard Name:
Technical requirements for drilling fluid sand content tester
Chinese Name:
钻井液含砂量测定仪技术条件
Standard category:
Oil and gas industry standards (SY)
-
Date of Release:
1991-07-19 -
Date of Implementation:
1991-12-01
China Standard Classification Number:
Petroleum>>Petroleum Exploration, Development and Gathering>>E13 Oil Drilling

Skip to download
Summary:
SY/T 5378-1991 Technical Specifications for Drilling Fluid Sand Content TesterSY/T5378-1991 Standard Download Decompression Password: www.bzxz.net

Some standard content:
Petroleum and Natural Gas Industry Standard of the People's Republic of China SY / T 5378---91
Technical requirements for drilling fluid sand content measuring instrument
Published on July 19, 1991
Ministry of Energy of the People's Republic of Chinabzxz.net
1991-12-01 Implementation
Subject content and scope of application
Petroleum and Natural Gas Industry Standard of the People's Republic of China Technical requirements for drilling fluid sand content measuring instrument
SY /T 537891
1.1 Subject content
This standard specifies the technical requirements, test methods, inspection rules and marking, packaging and storage requirements for drilling fluid sand content measuring instrument. 1.2 Scope of application
This standard applies to drilling fluid sand content measuring instrument (hereinafter referred to as instrument). 2 Reference standards
ZBY002 Basic environmental conditions and test methods for transportation and storage of instruments and meters ZBY003 General technical conditions for packaging of instruments and meters 3 Technical requirements
3.1 Normal working conditions
a. Ambient temperature: 5~40℃;
b. Relative humidity: 5%~95%;
c. Atmospheric pressure: 86~108kPa
d. The ambient air does not contain media that corrode chromium, nickel plating, non-ferrous metals and their alloys. The nominal capacity of glass test tubes and their capacity tolerances 3.2
The white content scale of the sand content volume and its bulk density tolerance shall comply with the provisions of Table 1. 3.2.1
Sand content volume percentage scale, %
Ministry of Energy of the People's Republic of China approved product on July 19, 1991
Capacity filling difference, %
199[-12-01 implementation
SY /T 537891
3.2.2The nominal capacity of drilling fluid volume is 30ml, and the capacity tolerance is ±2%. 3.2.3The nominal capacity of water volume is 100ml, and the capacity tolerance is ±1%. 3.3Appearance
Ugly: The glass test tube should be smooth, transparent, with clear scale, and no defects such as cracks and gaps. The screen of h200 days should be flat: there should be no damage, looseness, etc.: c. The inner wall of the funnel should be smooth: there should be no defects such as cracks and scratches. 3.4 Performance against transport environment
The instrument shall meet the requirements of ZBY002 under the conditions of transport packaging, including +55℃ for high temperature test, -40℃ for low temperature test, 95% for relative humidity (at 25℃), and 250mm for falling from the mountain. After the test, the instrument shall meet the requirements of Article 3.3 of this standard.
4 Test method
4.1 Test conditions
Temperature: 15~35℃ (the maximum allowable temperature change rate is 1℃/10min); a.
b. Relative humidity: 45%~75%;
c. Air pressure 86~106kPa.
4.2 Test equipment and materials
a. Burette: Class A. 1, 5, 10, 20ml each. b. Distilled water: 100ml or more.
4.3 The nominal capacity of the glass test tube and its capacity tolerance test adopts the injection comparison method. Use a clean, dry burette to draw different amounts of distilled water in turn and record the amount drawn: then inject it into the glass test tube, observe that the liquid level rises to the corresponding scale, stop injecting: calculate the difference between the actual injection amount and the nominal capacity, and the difference shall not exceed the provisions of Article 3.2.
4.4 Appearance inspection
The appearance and marking of the instrument shall meet the requirements of Article 3.3 and Article 6.1 by sensory inspection. 4.5 Anti-transport environment performance test
The test shall be carried out in accordance with the provisions of ZBY002. After the test, remove the packaging and check the requirements of Article 3.3 in accordance with the method of Article 4.4. 5 Inspection rules
5.1 Factory inspection
Each instrument shall be inspected by the technical inspection department of the manufacturer before it can be shipped out of the factory. The inspection of the instrument shall be carried out in accordance with the provisions of Table 2. Table 2
Technical requirements Article number
5.2 Type inspection
Item name
Nominal capacity of glass test tube and its capacity tolerance
Test method Article number
Type inspection of the instrument shall be carried out in accordance with the requirements of Articles 3.2 to 3.4, 6.1 and the test methods of Articles 4.3 to 4.5. 2
6 Marking, packaging and storage
6.1 Marking
SY /T 5378-91
A mark or nameplate shall be attached to the appropriate position of the instrument. It shall indicate: manufacturer name or factory mark
b, instrument name and model;
c. Manufacturing number;
d. Year and month of manufacturing.
6.2 Packaging
The instrument for transportation in boxes shall be packed with the complete set of accessories specified in the instructions and in accordance with the provisions of ZBY003. The glass test tube shall be packed in shockproof packaging.
6.3 Storage
The instrument shall be stored in a ventilated room with an ambient temperature of 5-40℃ and a relative humidity of 10%-90%. The indoor air shall not contain harmful impurities that can corrode the instrument.
Additional instructions:
This standard was proposed by China National Petroleum Corporation. This standard is under the jurisdiction of the Petroleum Instruments and Meters Professional Standardization Committee of China National Petroleum Corporation. This standard was drafted by the Lanzhou Refining and Chemical Industry General Instruments of China Petrochemical Corporation, and the main drafters of this standard are Rong Cui and Ding Youwei. This standard refers to the American Petroleum Institute specification APIRP13B publication "Recommended Practice for Standard Procedures for Testing Drilling Fluids" (10th edition, June 1984). This standard is still valid after the review in 199, and the review results have been approved by the State Administration of Petroleum and Chemical Industry.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Technical requirements for drilling fluid sand content measuring instrument
Published on July 19, 1991
Ministry of Energy of the People's Republic of Chinabzxz.net
1991-12-01 Implementation
Subject content and scope of application
Petroleum and Natural Gas Industry Standard of the People's Republic of China Technical requirements for drilling fluid sand content measuring instrument
SY /T 537891
1.1 Subject content
This standard specifies the technical requirements, test methods, inspection rules and marking, packaging and storage requirements for drilling fluid sand content measuring instrument. 1.2 Scope of application
This standard applies to drilling fluid sand content measuring instrument (hereinafter referred to as instrument). 2 Reference standards
ZBY002 Basic environmental conditions and test methods for transportation and storage of instruments and meters ZBY003 General technical conditions for packaging of instruments and meters 3 Technical requirements
3.1 Normal working conditions
a. Ambient temperature: 5~40℃;
b. Relative humidity: 5%~95%;
c. Atmospheric pressure: 86~108kPa
d. The ambient air does not contain media that corrode chromium, nickel plating, non-ferrous metals and their alloys. The nominal capacity of glass test tubes and their capacity tolerances 3.2
The white content scale of the sand content volume and its bulk density tolerance shall comply with the provisions of Table 1. 3.2.1
Sand content volume percentage scale, %
Ministry of Energy of the People's Republic of China approved product on July 19, 1991
Capacity filling difference, %
199[-12-01 implementation
SY /T 537891
3.2.2The nominal capacity of drilling fluid volume is 30ml, and the capacity tolerance is ±2%. 3.2.3The nominal capacity of water volume is 100ml, and the capacity tolerance is ±1%. 3.3Appearance
Ugly: The glass test tube should be smooth, transparent, with clear scale, and no defects such as cracks and gaps. The screen of h200 days should be flat: there should be no damage, looseness, etc.: c. The inner wall of the funnel should be smooth: there should be no defects such as cracks and scratches. 3.4 Performance against transport environment
The instrument shall meet the requirements of ZBY002 under the conditions of transport packaging, including +55℃ for high temperature test, -40℃ for low temperature test, 95% for relative humidity (at 25℃), and 250mm for falling from the mountain. After the test, the instrument shall meet the requirements of Article 3.3 of this standard.
4 Test method
4.1 Test conditions
Temperature: 15~35℃ (the maximum allowable temperature change rate is 1℃/10min); a.
b. Relative humidity: 45%~75%;
c. Air pressure 86~106kPa.
4.2 Test equipment and materials
a. Burette: Class A. 1, 5, 10, 20ml each. b. Distilled water: 100ml or more.
4.3 The nominal capacity of the glass test tube and its capacity tolerance test adopts the injection comparison method. Use a clean, dry burette to draw different amounts of distilled water in turn and record the amount drawn: then inject it into the glass test tube, observe that the liquid level rises to the corresponding scale, stop injecting: calculate the difference between the actual injection amount and the nominal capacity, and the difference shall not exceed the provisions of Article 3.2.
4.4 Appearance inspection
The appearance and marking of the instrument shall meet the requirements of Article 3.3 and Article 6.1 by sensory inspection. 4.5 Anti-transport environment performance test
The test shall be carried out in accordance with the provisions of ZBY002. After the test, remove the packaging and check the requirements of Article 3.3 in accordance with the method of Article 4.4. 5 Inspection rules
5.1 Factory inspection
Each instrument shall be inspected by the technical inspection department of the manufacturer before it can be shipped out of the factory. The inspection of the instrument shall be carried out in accordance with the provisions of Table 2. Table 2
Technical requirements Article number
5.2 Type inspection
Item name
Nominal capacity of glass test tube and its capacity tolerance
Test method Article number
Type inspection of the instrument shall be carried out in accordance with the requirements of Articles 3.2 to 3.4, 6.1 and the test methods of Articles 4.3 to 4.5. 2
6 Marking, packaging and storage
6.1 Marking
SY /T 5378-91
A mark or nameplate shall be attached to the appropriate position of the instrument. It shall indicate: manufacturer name or factory mark
b, instrument name and model;
c. Manufacturing number;
d. Year and month of manufacturing.
6.2 Packaging
The instrument for transportation in boxes shall be packed with the complete set of accessories specified in the instructions and in accordance with the provisions of ZBY003. The glass test tube shall be packed in shockproof packaging.
6.3 Storage
The instrument shall be stored in a ventilated room with an ambient temperature of 5-40℃ and a relative humidity of 10%-90%. The indoor air shall not contain harmful impurities that can corrode the instrument.
Additional instructions:
This standard was proposed by China National Petroleum Corporation. This standard is under the jurisdiction of the Petroleum Instruments and Meters Professional Standardization Committee of China National Petroleum Corporation. This standard was drafted by the Lanzhou Refining and Chemical Industry General Instruments of China Petrochemical Corporation, and the main drafters of this standard are Rong Cui and Ding Youwei. This standard refers to the American Petroleum Institute specification APIRP13B publication "Recommended Practice for Standard Procedures for Testing Drilling Fluids" (10th edition, June 1984). This standard is still valid after the review in 199, and the review results have been approved by the State Administration of Petroleum and Chemical Industry.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG/T 2091-1991 Chlorinated paraffin-42
- QB/T 3605-1999 Canned dace with fermented black beans
- GBJ 51-1983 Chimney design specification GBJ51-83
- JB/T 3627.10-1999 Tools and accessories for assembly of modular fixtures Hollow boring fixture inspection rod
- GB/T 9172-1988 Scented tea grade preform
- GB 11803-1989 Structure and basic dimensions of marine AC low voltage switchboard
- GB 15892-2003 Water treatment agent polyaluminium chloride
- GB/T 3402-1994 GB/T 3402-1994 Nomenclature of vinyl chloride homopolymer and copolymer resins
- GB/T 19729-2005 Electronic imaging-Media error monitoring and reporting techniques for verification of stored data on optical digital data disks
- GB/T 15378-1994 Terminology of woodworking machine tools Woodworking saws
- HG/T 2435-1993 Glass tubes and fittings
- HG/T 20542-1992 Technical conditions for masonry of calcium carbide furnace
- GB/T 31023-2014 Mobile laboratory—General specification for equipment operating condition test
- JB/T 9921.1-1999 Bearing inner ring groove superfinishing machine and bearing outer ring groove superfinishing machine precision inspection
- GB/T 8803-2001 Thermal oven test method for injection molded rigid polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C), acrylonitrile-butadiene-styrene terpolymer (ABS) and acrylonitrile-styrene-acrylate terpolymer (ASA) pipe fittings
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]