GB 19079.4-2005 Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues
time:
2024-08-05 21:06:28
- GB 19079.4-2005
- in force
Standard ID:
GB 19079.4-2005
Standard Name:
Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues
Chinese Name:
体育场所开放条件与技术要求 第4部分:攀岩场所
Standard category:
National Standard (GB)
-
Date of Release:
2005-01-24 -
Date of Implementation:
2005-06-01
Standard ICS number:
Household and commercial equipment, recreation, sports >> 97.220 Sports equipment and facilitiesChina Standard Classification Number:
Light Industry, Culture and Living Goods>>Culture, Education, Sports and Entertainment Goods>>Y55 Sports Facilities and Equipment
publishing house:
China Standards PressISBN:
155066.1-22402Publication date:
2005-02-17Plan number:
20032357-Q-451
Release date:
2005-01-24Drafter:
Hao Guangan, Xue Yun, Chen Xueling, Liu Daqing, Li Zhixin, Yang Shitao, Wang Liquan, Shi Chunjian, Li ZhiDrafting Organization:
Mountaineering Management Center of the State Sports General Administration, Peking UniversityFocal point Organization:
Sports Economics Department of the State Sports General AdministrationProposing Organization:
State Sports General AdministrationPublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Standardization Administration of ChinaCompetent Authority:
State Sports General Administration

Skip to download
Summary:
This part of GB 19079 stipulates the basic conditions and basic technical requirements for the opening of rock climbing venues. This part applies to all types of rock climbing venues open to the public. GB 19079.4-2005 Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues GB19079.4-2005 Standard download decompression password: www.bzxz.net

Some standard content:
ICS97.220
National Standard of the People's Republic of China
GB19079.4—2005
Operation conditions and technical requirements for gymnasium and playgroundPart 4: Rock elimbing place
2005-01-24Promulgated
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaStandardization Administration of the People's Republic of ChinaLast meeting
2005-06-01Implementation
GB19079 Operation conditions and technical requirements for gymnasium and playgroundPart 4: Rock elimbing place ;
-Part 6: Skiing places;
Part 7: Skating places:
Part 8: Shooting places:
Part 9: Archery places:
-Part 10: Diving places;
Part 11: Rafting places:
Part 12: Paragliding places;
--Part 13: Hot air balloon places:
Part 14: Powered paragliding places;bzxz.net
This part is Part 4 of GB190?9. All the contents of this part are mandatory. This part is proposed by the State Sports General Administration.
This part is under the jurisdiction of the Sports Economics Department of the State Sports General Administration and is responsible for interpretation. Drafting units of this part: Mountaineering Sports Management Center of the State Sports General Administration and Peking University. GB 19079, 4—2005
The main drafters of this part are Hao Guangan, Xue Yun, Chen Xueling, Liu Daqing, Li Zhixin, Yang Shitao, Qi Liquan, Shi Chunjian and Li Zhi. 1 Scope
Opening conditions and technical requirements for sports venues
Part 4: Rock climbing venues
GB19079.4—2005
(This part of GB19079 specifies the basic conditions and basic technical requirements for the opening of climbing venues. This part is applicable to all kinds of climbing venues open to the public. 2 Normative references
The clauses in the following documents become the clauses of this standard through the reference of this standard. For the applicable documents of the period indicated, all amendments (excluding errata) or revisions thereto shall not apply to this standard. However, the parties to the agreement reached under this standard are encouraged to study whether the latest versions of these documents can be used. The latest version of the dated referenced documents shall apply to this standard. GB6566 Standard for radionuclides of building materials GB9668 Hygiene standard for gymnasiums GB/T17093 Total number of bacteria in indoor air GB/18883-2002 Standard for indoor air quality CR/T100C? 1 Symbols for signs Part 1: General symbols 3 Terms and definitions Rock climbing place Rock climbing place A place where people can carry out rock climbing (climbing) sports training, competition, fitness and leisure activities. It includes: artificial rock climbing places and natural rock climbing places. Artificial rock wall Climbingruck is a kind of artificial rock wall constructed indoors or outdoors for rock climbing. 3.3 Rock climbing technical instructor refers to the person who teaches climbing sports theory and skills. 4 Qualification of practitioners Rock climbing technical instructors and others should hold relevant national qualifications for the hot industry. 5 Site, facilities and equipment conditions 5.1 Artificial rock wall 5.1.1 The maximum force of the upper anchor point shall not be less than 816.33kg square, 5.1.2 The maximum force of the protective hanging piece shall not be less than 816.33kg force. 5.1.3 The static pressure resistance of the rock plate shall not be less than 108.16kg force. 5. 1. 4 The maximum impact resistance of the rock plate shall not be less than 612. 24 kg force, 5. t.5 The maximum tensile resistance of the fulcrum hole shall not be less than 306. 12 kg force. 19079.4-2005
5.2 Natural rock trap
5.2.1 The maximum force of the upper pin point shall not be less than 816.33 kg force, 5.2.2 The maximum force of the protection hanging piece shall not be less than 816. 33 kg force, 5.3 Protection equipment
5.3. 1 The diameter of the protection rope shall not be less than 10 mm, and the tensile strength shall not be less than 700 kg force. The ear adopts a single rope protection state: 5.3.2 The lateral tensile strength of the threaded safety iron lock shall not be less than 918.33 kg force, and the longitudinal tensile strength shall not be less than 2241.90 kg force. 5.3.3 The lateral tensile strength of the safety iron lock shall not be less than 714.29 kg force, and the longitudinal tensile strength shall not be less than 2244.90 kg force. 5.3.4 The tensile strength of the brake (descender) shall not be less than 2448.98 kg force. 5.3.5 The tensile strength of the safety belt shall not be less than 1 734.69 kg. 5.4 Auxiliary equipment
5.4.1 There shall be clear and eye-catching warning signs and safety protection facilities for dangerous areas. 5.4.2 There shall be men's and women's changing rooms with facilities for storing clothes. 5.4.3 The rock climbing site in the kiln shall have emergency evacuation passages. 5.4.4 The public signs and signs of the rock climbing site shall comply with the requirements of GB/T10001.1. 6 Sanitation and environmental management requirements
Artificial rock walls shall comply with the requirements of GB6566. 6.2 The environmental sanitation of the rock climbing site shall comply with the requirements of GB9668. 6.3 The indoor air of the rock climbing site shall comply with the requirements of GB/T17093 and (:B/T18883-2002. 7 Safety Assurance
7.1 There shall be "Instructions for Rock Climbers" and safety warnings at the wake-up position. 7.2 During the opening period, each rock climbing trail in use shall be equipped with a rock climbing technical instructor. 7.3 There shall be a sound safety inspection system for facilities and equipment. Damaged equipment shall be replaced in a timely manner. 7.4 First aid medicines and equipment shall be placed in a conspicuous location for use. 7.5 There shall be clear signs for all types of personnel to take up their posts.
7.6 There shall be a sound security protection, safety education and care, equipment maintenance system and personnel service post responsibility system.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
GB19079.4—2005
Operation conditions and technical requirements for gymnasium and playgroundPart 4: Rock elimbing place
2005-01-24Promulgated
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaStandardization Administration of the People's Republic of ChinaLast meeting
2005-06-01Implementation
GB19079 Operation conditions and technical requirements for gymnasium and playgroundPart 4: Rock elimbing place ;
-Part 6: Skiing places;
Part 7: Skating places:
Part 8: Shooting places:
Part 9: Archery places:
-Part 10: Diving places;
Part 11: Rafting places:
Part 12: Paragliding places;
--Part 13: Hot air balloon places:
Part 14: Powered paragliding places;bzxz.net
This part is Part 4 of GB190?9. All the contents of this part are mandatory. This part is proposed by the State Sports General Administration.
This part is under the jurisdiction of the Sports Economics Department of the State Sports General Administration and is responsible for interpretation. Drafting units of this part: Mountaineering Sports Management Center of the State Sports General Administration and Peking University. GB 19079, 4—2005
The main drafters of this part are Hao Guangan, Xue Yun, Chen Xueling, Liu Daqing, Li Zhixin, Yang Shitao, Qi Liquan, Shi Chunjian and Li Zhi. 1 Scope
Opening conditions and technical requirements for sports venues
Part 4: Rock climbing venues
GB19079.4—2005
(This part of GB19079 specifies the basic conditions and basic technical requirements for the opening of climbing venues. This part is applicable to all kinds of climbing venues open to the public. 2 Normative references
The clauses in the following documents become the clauses of this standard through the reference of this standard. For the applicable documents of the period indicated, all amendments (excluding errata) or revisions thereto shall not apply to this standard. However, the parties to the agreement reached under this standard are encouraged to study whether the latest versions of these documents can be used. The latest version of the dated referenced documents shall apply to this standard. GB6566 Standard for radionuclides of building materials GB9668 Hygiene standard for gymnasiums GB/T17093 Total number of bacteria in indoor air GB/18883-2002 Standard for indoor air quality CR/T100C? 1 Symbols for signs Part 1: General symbols 3 Terms and definitions Rock climbing place Rock climbing place A place where people can carry out rock climbing (climbing) sports training, competition, fitness and leisure activities. It includes: artificial rock climbing places and natural rock climbing places. Artificial rock wall Climbingruck is a kind of artificial rock wall constructed indoors or outdoors for rock climbing. 3.3 Rock climbing technical instructor refers to the person who teaches climbing sports theory and skills. 4 Qualification of practitioners Rock climbing technical instructors and others should hold relevant national qualifications for the hot industry. 5 Site, facilities and equipment conditions 5.1 Artificial rock wall 5.1.1 The maximum force of the upper anchor point shall not be less than 816.33kg square, 5.1.2 The maximum force of the protective hanging piece shall not be less than 816.33kg force. 5.1.3 The static pressure resistance of the rock plate shall not be less than 108.16kg force. 5. 1. 4 The maximum impact resistance of the rock plate shall not be less than 612. 24 kg force, 5. t.5 The maximum tensile resistance of the fulcrum hole shall not be less than 306. 12 kg force. 19079.4-2005
5.2 Natural rock trap
5.2.1 The maximum force of the upper pin point shall not be less than 816.33 kg force, 5.2.2 The maximum force of the protection hanging piece shall not be less than 816. 33 kg force, 5.3 Protection equipment
5.3. 1 The diameter of the protection rope shall not be less than 10 mm, and the tensile strength shall not be less than 700 kg force. The ear adopts a single rope protection state: 5.3.2 The lateral tensile strength of the threaded safety iron lock shall not be less than 918.33 kg force, and the longitudinal tensile strength shall not be less than 2241.90 kg force. 5.3.3 The lateral tensile strength of the safety iron lock shall not be less than 714.29 kg force, and the longitudinal tensile strength shall not be less than 2244.90 kg force. 5.3.4 The tensile strength of the brake (descender) shall not be less than 2448.98 kg force. 5.3.5 The tensile strength of the safety belt shall not be less than 1 734.69 kg. 5.4 Auxiliary equipment
5.4.1 There shall be clear and eye-catching warning signs and safety protection facilities for dangerous areas. 5.4.2 There shall be men's and women's changing rooms with facilities for storing clothes. 5.4.3 The rock climbing site in the kiln shall have emergency evacuation passages. 5.4.4 The public signs and signs of the rock climbing site shall comply with the requirements of GB/T10001.1. 6 Sanitation and environmental management requirements
Artificial rock walls shall comply with the requirements of GB6566. 6.2 The environmental sanitation of the rock climbing site shall comply with the requirements of GB9668. 6.3 The indoor air of the rock climbing site shall comply with the requirements of GB/T17093 and (:B/T18883-2002. 7 Safety Assurance
7.1 There shall be "Instructions for Rock Climbers" and safety warnings at the wake-up position. 7.2 During the opening period, each rock climbing trail in use shall be equipped with a rock climbing technical instructor. 7.3 There shall be a sound safety inspection system for facilities and equipment. Damaged equipment shall be replaced in a timely manner. 7.4 First aid medicines and equipment shall be placed in a conspicuous location for use. 7.5 There shall be clear signs for all types of personnel to take up their posts.
7.6 There shall be a sound security protection, safety education and care, equipment maintenance system and personnel service post responsibility system.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- SJ/T 11062-1996 Stranded tungsten wire
- GB/T 15417-1994 Documentation-Guidelines for establishment and development of multilingual thesauri
- JB/T 2001.40-1999 Water system filling valve (PN=20MPa)
- GB/T 12366.4-1991 Guideline for the work of complex standardization Drafting method for program of standard-complex
- GB/T 20001.4-2001 Rules for drafting STANDARDs--Part 4:Methods of chemical analysis (ISO 78-2:1999,Chemistry--Layout for STANDARDs--Part 2:Methods of chemical analysis,MOD)
- JB/T 9541-1999 General technical requirements for motors for household ventilation fans
- GB/T 5773-2004 Performance test methods for positive displacement refrigerant compressors
- GB/T 5095.2-1997 Basic test procedures and measurement methods for electromechanical components for electronic equipment Part 2: General inspection, electrical continuity and contact resistance test, insulation test and voltage stress test
- QB/T 1678-1993 Bleached kraft pulp
- QB/T 2370-1998 Can filling production line
- GB/T 14978-1994 Continuously hot-dip aluminum-zinc-silicon alloy coated steel strip and steel sheet
- GB/T 27857-2011 Chemicals—Anaerobic biodegradability of organic compounds in digested sludge—By measurement of gas production
- GB 16350-1996 Standard for radiation health protection for children during X-ray diagnosis
- GB 16487.4-1996 Imported Waste Environmental Protection Control Standard Waste Paper or Cardboard
- GBZ 135-2002 Standard for sanitary protection of sealed gamma radiation source containers
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]