
JB/T 6641-1993 Residual magnetism of rolling bearings and its evaluation method
time:
1993-05-07 15:00:00
- JB/T 6641-1993
- Abolished
Standard ID:
JB/T 6641-1993
Standard Name:
Residual magnetism of rolling bearings and its evaluation method
Chinese Name:
滚动轴承 残磁及其评定方法
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1993-05-07 -
Date of Implementation:
1994-01-01 -
Date of Expiration:
2007-09-01
China Standard Classification Number:
Machinery>>General Parts>>J11 Rolling Bearings
alternative situation:
Replaced by JB/T 6641-2007

Skip to download
Summary:
This standard specifies the residual magnetism limits, measurement methods and inspection rules for rolling bearings. This standard is applicable to the inspection and acceptance of residual magnetism of various types of general-purpose bearings with an outer diameter less than 430mm by manufacturers and users. JB/T 6641-1993 Residual magnetism of rolling bearings and its evaluation method JB/T6641-1993 Standard download and decompression password: www.bzxz.net

Some standard content:
J11 | | tt | | JB | |Residual magnetism and its evaluation method
Implemented on 1994-01-01
Ministry of Machinery Industry of the People's Republic of China
Published
Machinery Industry Standard of the People's Republic of China||tt| |Residual magnetism and its evaluation method
Rolling bearings
1 Subject content and scope of application
This standard specifies the residual magnetization limits, measurement methods and inspection rules for rolling bearings (hereinafter referred to as bearings) . JB/T664193
This standard is applicable to the inspection and acceptance of residual formaldehyde in various types of general-purpose bearings with an outer diameter less than 430mm by manufacturers and users. Reference standards
ZBJ11020
3 Definitions and units of quantities
Quantities and units of electricity and magnetism||tt| | Inspection rules for rolling bearings and their commercial parts 3.1 Residual magnetism refers to the residual magnetism after the bearing has been magnetized and demagnetized. 3.2 Residual magnetism is expressed by magnetic induction intensity, and its unit is Punta (mT). 4 Residual magnetism value
The residual magnetism value should not exceed the following table:
Bearing outer diameter
exceeds
Maximum residual magnetism mT
5Measurement method
0. 5||tt ||50
430||tt ||1. 0
5.1 The residual magnetism measurement adopts the Frost effect principle. The measuring instrument must have a range of 1mT and an accuracy of ±3%. The specifications of the Zhaier element equipped with the instrument are: 4mm×2mm×0.2mm, and the distance between the plane of the Hall element and the measured surface is 1±0.05mm (see Figure 1). Probe
Jidong components
Non-introduction workbench
Figure 1
Approved by the Ministry of Machinery Industry 1993-05-07
Measurement diagram||tt ||Implemented on 1994-01-01
JB/T6641-93
5.2 When measuring residual magnetism, the measured maximum value shall be the residual magnetism value of the bearing. 5.3 It is not allowed to measure on a magnetic workbench or in an environmental magnetic field that is greater than the geomagnetic field. 5.4 For ball bearings, roller bearings and needle roller bearings, the measurement parts are the end faces and chamfers of the inner and outer rings (or shafts or seat rings). Separable bearings, spherical roller bearings and spherical ball bearings should also be measured. base rolling element. Separable bearings should be measured after separation; spherical roller bearings and self-aligning ball bearings should be measured with the inner and outer diagrams at 90° to each other. If the residual magnetism of the rolling elements is found to be at the junction with the cage, the rolling elements can be rotated. Measure after cooling
5.5 When measuring the residual magnetism on the bearing end face, the probe should be perpendicular to the position of the bearing end face. When measuring the bearing chamfer and rolling element residual magnetism, the probe can be tilted appropriately, but the inclination angle should not be greater than 45°. .
5.6 When the residual magnetism on the bearing sleeve or rolling element is close to the specified value, the bearing end surface should be placed in a flat position first, and then measured in the east-west direction to reduce the influence of the geomagnetic field (see figure 2), North
Detect the amount of residual magnetism
Figure 2 How to avoid the geomagnetic field
5.7 The distribution of residual magnetism on the bearing is random. When measuring, the probe is on the bearing The measurement position cannot be preset, and the movement of the probe should be such that it can reach any measured part on the bearing. The measurement method of the circumferential probe is not applicable to this standard. 6 Inspection Rules
Bearing residual magnetism shall be subject to sampling inspection in accordance with the provisions of ZBJ11020. The sample size shall be selected according to the general inspection level 1, and the qualified quality level AQL value shall be selected according to 4. bzxZ.net
Additional notes:
This standard is proposed by the National Rolling Bearing Standardization Technical Committee. This standard is under the jurisdiction of the Luoyang Bearing Research Institute of the Ministry of Machinery Industry. This standard is drafted by Shanghai Bearing Technology Research Institute. The drafters of this standard are Wang Jun and Yan Xiali.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Implemented on 1994-01-01
Ministry of Machinery Industry of the People's Republic of China
Published
Machinery Industry Standard of the People's Republic of China||tt| |Residual magnetism and its evaluation method
Rolling bearings
1 Subject content and scope of application
This standard specifies the residual magnetization limits, measurement methods and inspection rules for rolling bearings (hereinafter referred to as bearings) . JB/T664193
This standard is applicable to the inspection and acceptance of residual formaldehyde in various types of general-purpose bearings with an outer diameter less than 430mm by manufacturers and users. Reference standards
ZBJ11020
3 Definitions and units of quantities
Quantities and units of electricity and magnetism||tt| | Inspection rules for rolling bearings and their commercial parts 3.1 Residual magnetism refers to the residual magnetism after the bearing has been magnetized and demagnetized. 3.2 Residual magnetism is expressed by magnetic induction intensity, and its unit is Punta (mT). 4 Residual magnetism value
The residual magnetism value should not exceed the following table:
Bearing outer diameter
exceeds
Maximum residual magnetism mT
5Measurement method
0. 5||tt ||50
430||tt ||1. 0
5.1 The residual magnetism measurement adopts the Frost effect principle. The measuring instrument must have a range of 1mT and an accuracy of ±3%. The specifications of the Zhaier element equipped with the instrument are: 4mm×2mm×0.2mm, and the distance between the plane of the Hall element and the measured surface is 1±0.05mm (see Figure 1). Probe
Jidong components
Non-introduction workbench
Figure 1
Approved by the Ministry of Machinery Industry 1993-05-07
Measurement diagram||tt ||Implemented on 1994-01-01
JB/T6641-93
5.2 When measuring residual magnetism, the measured maximum value shall be the residual magnetism value of the bearing. 5.3 It is not allowed to measure on a magnetic workbench or in an environmental magnetic field that is greater than the geomagnetic field. 5.4 For ball bearings, roller bearings and needle roller bearings, the measurement parts are the end faces and chamfers of the inner and outer rings (or shafts or seat rings). Separable bearings, spherical roller bearings and spherical ball bearings should also be measured. base rolling element. Separable bearings should be measured after separation; spherical roller bearings and self-aligning ball bearings should be measured with the inner and outer diagrams at 90° to each other. If the residual magnetism of the rolling elements is found to be at the junction with the cage, the rolling elements can be rotated. Measure after cooling
5.5 When measuring the residual magnetism on the bearing end face, the probe should be perpendicular to the position of the bearing end face. When measuring the bearing chamfer and rolling element residual magnetism, the probe can be tilted appropriately, but the inclination angle should not be greater than 45°. .
5.6 When the residual magnetism on the bearing sleeve or rolling element is close to the specified value, the bearing end surface should be placed in a flat position first, and then measured in the east-west direction to reduce the influence of the geomagnetic field (see figure 2), North
Detect the amount of residual magnetism
Figure 2 How to avoid the geomagnetic field
5.7 The distribution of residual magnetism on the bearing is random. When measuring, the probe is on the bearing The measurement position cannot be preset, and the movement of the probe should be such that it can reach any measured part on the bearing. The measurement method of the circumferential probe is not applicable to this standard. 6 Inspection Rules
Bearing residual magnetism shall be subject to sampling inspection in accordance with the provisions of ZBJ11020. The sample size shall be selected according to the general inspection level 1, and the qualified quality level AQL value shall be selected according to 4. bzxZ.net
Additional notes:
This standard is proposed by the National Rolling Bearing Standardization Technical Committee. This standard is under the jurisdiction of the Luoyang Bearing Research Institute of the Ministry of Machinery Industry. This standard is drafted by Shanghai Bearing Technology Research Institute. The drafters of this standard are Wang Jun and Yan Xiali.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 7858-1995 Hydraulic component cleanliness assessment method and hydraulic component cleanliness index
- GB 12943-1991 Quarantine procedures for virus-free mother trees and seedlings of apples
- SJ 3235-1989 Ribbon getter made of Zirconium and Aluminium
- GB/T 40094.2-2021 Electronic commerce data transaction—Part 2:Data description specification
- SJ/T 10090-1991 The methods for detemination of ZnS and CdS for use in phosphors
- JB/T 10231.13-2002 Tool product testing methods Part 13: Saw blades and milling cutters
- JB/T 6004-1992 Technical requirements for oil bath and oil immersed air filter assemblies for internal combustion engines
- GB/T 3108-1999 Impressed current cathodic protection system for hulls
- SY/T 5505-1992 Cluster well overall design method
- GB 4869-1985 Occupational local vibration disease diagnosis standard and treatment principles
- JB/T 9711-2001 General technical requirements for single-stage centrifugal turbine torque converters
- GB/T 9649.10-2001 The terminology classification codes of geology and mineral resources--Petrology
- JB 3726.1-1984 General technical requirements for boiler deslagging equipment manufacturing standards
- JB/T 3711.1-1999 Terminology and classification of centralized lubrication systems
- GB 16895.11-2001 Electrical installations in buildings Part 4: Safety protection Chapter 44: Overvoltage protection Section 442: Protection of low-voltage electrical installations against temporary overvoltages and faults between the high-voltage system and earth
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com