JB/T 6641-1993 Residual magnetism of rolling bearings and its evaluation method
time:
1993-05-07 15:00:00
- JB/T 6641-1993
- Abolished
Standard ID:
JB/T 6641-1993
Standard Name:
Residual magnetism of rolling bearings and its evaluation method
Chinese Name:
滚动轴承 残磁及其评定方法
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1993-05-07 -
Date of Implementation:
1994-01-01 -
Date of Expiration:
2007-09-01
China Standard Classification Number:
Machinery>>General Parts>>J11 Rolling Bearings
alternative situation:
Replaced by JB/T 6641-2007

Skip to download
Summary:
This standard specifies the residual magnetism limits, measurement methods and inspection rules for rolling bearings. This standard is applicable to the inspection and acceptance of residual magnetism of various types of general-purpose bearings with an outer diameter less than 430mm by manufacturers and users. JB/T 6641-1993 Residual magnetism of rolling bearings and its evaluation method JB/T6641-1993 Standard download and decompression password: www.bzxz.net

Some standard content:
J11 | | tt | | JB | |Residual magnetism and its evaluation method
Implemented on 1994-01-01
Ministry of Machinery Industry of the People's Republic of China
Published
Machinery Industry Standard of the People's Republic of China||tt| |Residual magnetism and its evaluation method
Rolling bearings
1 Subject content and scope of application
This standard specifies the residual magnetization limits, measurement methods and inspection rules for rolling bearings (hereinafter referred to as bearings) . JB/T664193
This standard is applicable to the inspection and acceptance of residual formaldehyde in various types of general-purpose bearings with an outer diameter less than 430mm by manufacturers and users. Reference standards
ZBJ11020
3 Definitions and units of quantities
Quantities and units of electricity and magnetism||tt| | Inspection rules for rolling bearings and their commercial parts 3.1 Residual magnetism refers to the residual magnetism after the bearing has been magnetized and demagnetized. 3.2 Residual magnetism is expressed by magnetic induction intensity, and its unit is Punta (mT). 4 Residual magnetism value
The residual magnetism value should not exceed the following table:
Bearing outer diameter
exceeds
Maximum residual magnetism mT
5Measurement method
0. 5||tt ||50
430||tt ||1. 0
5.1 The residual magnetism measurement adopts the Frost effect principle. The measuring instrument must have a range of 1mT and an accuracy of ±3%. The specifications of the Zhaier element equipped with the instrument are: 4mm×2mm×0.2mm, and the distance between the plane of the Hall element and the measured surface is 1±0.05mm (see Figure 1). Probe
Jidong components
Non-introduction workbench
Figure 1
Approved by the Ministry of Machinery Industry 1993-05-07
Measurement diagram||tt ||Implemented on 1994-01-01
JB/T6641-93
5.2 When measuring residual magnetism, the measured maximum value shall be the residual magnetism value of the bearing. 5.3 It is not allowed to measure on a magnetic workbench or in an environmental magnetic field that is greater than the geomagnetic field. 5.4 For ball bearings, roller bearings and needle roller bearings, the measurement parts are the end faces and chamfers of the inner and outer rings (or shafts or seat rings). Separable bearings, spherical roller bearings and spherical ball bearings should also be measured. base rolling element. Separable bearings should be measured after separation; spherical roller bearings and self-aligning ball bearings should be measured with the inner and outer diagrams at 90° to each other. If the residual magnetism of the rolling elements is found to be at the junction with the cage, the rolling elements can be rotated. Measure after cooling
5.5 When measuring the residual magnetism on the bearing end face, the probe should be perpendicular to the position of the bearing end face. When measuring the bearing chamfer and rolling element residual magnetism, the probe can be tilted appropriately, but the inclination angle should not be greater than 45°. .
5.6 When the residual magnetism on the bearing sleeve or rolling element is close to the specified value, the bearing end surface should be placed in a flat position first, and then measured in the east-west direction to reduce the influence of the geomagnetic field (see figure 2), North
Detect the amount of residual magnetism
Figure 2 How to avoid the geomagnetic field
5.7 The distribution of residual magnetism on the bearing is random. When measuring, the probe is on the bearing The measurement position cannot be preset, and the movement of the probe should be such that it can reach any measured part on the bearing. The measurement method of the circumferential probe is not applicable to this standard. 6 Inspection Rules
Bearing residual magnetism shall be subject to sampling inspection in accordance with the provisions of ZBJ11020. The sample size shall be selected according to the general inspection level 1, and the qualified quality level AQL value shall be selected according to 4.
Additional notes:www.bzxz.net
This standard is proposed by the National Rolling Bearing Standardization Technical Committee. This standard is under the jurisdiction of the Luoyang Bearing Research Institute of the Ministry of Machinery Industry. This standard is drafted by Shanghai Bearing Technology Research Institute. The drafters of this standard are Wang Jun and Yan Xiali.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Implemented on 1994-01-01
Ministry of Machinery Industry of the People's Republic of China
Published
Machinery Industry Standard of the People's Republic of China||tt| |Residual magnetism and its evaluation method
Rolling bearings
1 Subject content and scope of application
This standard specifies the residual magnetization limits, measurement methods and inspection rules for rolling bearings (hereinafter referred to as bearings) . JB/T664193
This standard is applicable to the inspection and acceptance of residual formaldehyde in various types of general-purpose bearings with an outer diameter less than 430mm by manufacturers and users. Reference standards
ZBJ11020
3 Definitions and units of quantities
Quantities and units of electricity and magnetism||tt| | Inspection rules for rolling bearings and their commercial parts 3.1 Residual magnetism refers to the residual magnetism after the bearing has been magnetized and demagnetized. 3.2 Residual magnetism is expressed by magnetic induction intensity, and its unit is Punta (mT). 4 Residual magnetism value
The residual magnetism value should not exceed the following table:
Bearing outer diameter
exceeds
Maximum residual magnetism mT
5Measurement method
0. 5||tt ||50
430||tt ||1. 0
5.1 The residual magnetism measurement adopts the Frost effect principle. The measuring instrument must have a range of 1mT and an accuracy of ±3%. The specifications of the Zhaier element equipped with the instrument are: 4mm×2mm×0.2mm, and the distance between the plane of the Hall element and the measured surface is 1±0.05mm (see Figure 1). Probe
Jidong components
Non-introduction workbench
Figure 1
Approved by the Ministry of Machinery Industry 1993-05-07
Measurement diagram||tt ||Implemented on 1994-01-01
JB/T6641-93
5.2 When measuring residual magnetism, the measured maximum value shall be the residual magnetism value of the bearing. 5.3 It is not allowed to measure on a magnetic workbench or in an environmental magnetic field that is greater than the geomagnetic field. 5.4 For ball bearings, roller bearings and needle roller bearings, the measurement parts are the end faces and chamfers of the inner and outer rings (or shafts or seat rings). Separable bearings, spherical roller bearings and spherical ball bearings should also be measured. base rolling element. Separable bearings should be measured after separation; spherical roller bearings and self-aligning ball bearings should be measured with the inner and outer diagrams at 90° to each other. If the residual magnetism of the rolling elements is found to be at the junction with the cage, the rolling elements can be rotated. Measure after cooling
5.5 When measuring the residual magnetism on the bearing end face, the probe should be perpendicular to the position of the bearing end face. When measuring the bearing chamfer and rolling element residual magnetism, the probe can be tilted appropriately, but the inclination angle should not be greater than 45°. .
5.6 When the residual magnetism on the bearing sleeve or rolling element is close to the specified value, the bearing end surface should be placed in a flat position first, and then measured in the east-west direction to reduce the influence of the geomagnetic field (see figure 2), North
Detect the amount of residual magnetism
Figure 2 How to avoid the geomagnetic field
5.7 The distribution of residual magnetism on the bearing is random. When measuring, the probe is on the bearing The measurement position cannot be preset, and the movement of the probe should be such that it can reach any measured part on the bearing. The measurement method of the circumferential probe is not applicable to this standard. 6 Inspection Rules
Bearing residual magnetism shall be subject to sampling inspection in accordance with the provisions of ZBJ11020. The sample size shall be selected according to the general inspection level 1, and the qualified quality level AQL value shall be selected according to 4.
Additional notes:www.bzxz.net
This standard is proposed by the National Rolling Bearing Standardization Technical Committee. This standard is under the jurisdiction of the Luoyang Bearing Research Institute of the Ministry of Machinery Industry. This standard is drafted by Shanghai Bearing Technology Research Institute. The drafters of this standard are Wang Jun and Yan Xiali.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 11597-1999 Procedure for exchanging control information and user data between a packet assembly and disassembly (PAD) facility and a packet-based DTE or another PAD
- YY 0336-2002 Disposable sterile vaginal dilator
- GB 16806-1997 General technical requirements for fire linkage control equipment
- HG/T 3521-1985 Determination of ethylenediaminetetramethylenephosphonic acid (EDTMPA) in phosphorus-based composite inhibitors for industrial circulating cooling water
- GB/T 4857.7-2005 Packaging—Basic tests for transport packages—Part 7:Sinusoidal vibration test method at constant frequency
- SY 6044-1994 Emergency evacuation conditions for shallow-water oil workers
- GB/T 2487-2001 普通磨具 磨石 技术条件
- HG/T 2239-1991 H06-2 Iron red, zinc yellow, iron black epoxy ester primer
- GB/T 14643.4-1993 Determination of soil fungi in industrial circulating cooling water - Plate count method
- GB/T 16830-2008 Bar code for commodity - Dispatch commodity numbering and bar code marking
- QB/T 3657.1-1999 Wood furniture finishing process Polyurethane varnish finishing process specification
- HG/T 21554.1-1995 Saddle ring packing
- JB/T 9999-1999 55° tapered pipe thread rolling plate
- JB/T 3364.3-1999 Technical requirements for horizontal circular sawing machines
- GB 8944.2-1988 Determination of bulk sales quality of pulp Part 2: Pulp cake (flash dried pulp) pulp bale
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com