HG/T 2347.4-1992 Determination of volatile matter from γ.Fe2O3 magnetic powder
time:
2024-08-13 08:22:12
- HG/T 2347.4-1992
- in force
Standard ID:
HG/T 2347.4-1992
Standard Name:
Determination of volatile matter from γ.Fe2O3 magnetic powder
Chinese Name:
γ.Fe2O3 磁粉挥发物的测定
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1992-06-01 -
Date of Implementation:
1993-03-01
Standard ICS number:
Imaging technology>>37.040 Photography technology Information technology, office machinery and equipment>>35.220 Data storage equipmentChina Standard Classification Number:
Chemicals>>Information Chemicals>>G83 Magnetic Recording Materials

Skip to download
Summary:
HG/T 2347.4-1992 Determination of volatile matter from γ.Fe2O3 magnetic powder HG/T2347.4-1992 standard download decompression password: www.bzxz.net

Some standard content:
Chemical Industry Standard of the People's Republic of China
Determination of volatiles in Y·Fe2O3 magnetic powder
Subject content and scope of application
This standard specifies the method for determining volatiles in Y·Fe2O3 magnetic powder for magnetic recording. HG/T2347.4—92
This standard is applicable to the determination of volatiles in Fe2O3 magnetic powder and modified Y·Fc,O3 magnetic powder for magnetic recording. Method summary
Dry the Fe,0 magnetic powder sample to be tested at 105±2℃ to constant weight, and calculate its volatile matter. 3 Instruments
3.1 Constant temperature drying oven: can be set at 105±2℃; 3.2 Balance: reading accuracy is 0.0001g, maximum load is 200g. 3.3 Dryer: filled with effective desiccant;
3.4 Weighing bottle: flat
Measurement steps
Take at least two samples for parallel measurement. Take 10±1g:Fe,0, magnetic powder sample (accurate to 0.0001g) and evenly spread it on the bottom of a weighing bottle (3.4) that has been weighed at 105±2℃ in advance, cover it with a lid, weigh the total amount (accurate to 0.0001g), then put the bottle cap upright at the bottle mouth, put it in a constant temperature drying oven (3.1) at 105±2℃, keep it for 2h, take it out and immediately cover it, transfer it to a desiccator (3.3) to cool to room temperature, weigh it (accurate to 0.0001g), heat it again for at least 30min, cool it in the desiccator (3.3), and weigh it: repeat this operation until the difference between two consecutive weighings does not exceed 0.005g, and record the lower weighing value. Calculation of the test results
The mass percentage of volatile matter (X) is calculated as follows: X
Where: mo—mass of the sample, g
m—mass of the dried sample, g.
6 Allowable difference
The allowable difference of the parallel test results of this method is less than 10%X100 of the higher valuebzxZ.net
Take the arithmetic mean of the parallel test results as the test result, and report it accurately to the second decimal place. Approved by the Ministry of Chemical Industry of the People's Republic of China on June 1, 199212
Standard Video Network wmbzmon.com Various American Standard Industry Data Free Download1993-03-01Implementation
Additional Notes:
HG/T2347.4-92
This standard is proposed by the Science and Technology Department of the Ministry of Chemical Industry of the People's Republic of China. This standard is under the jurisdiction of the Ministry of Chemical Industry's magnetic recording material standardization technology unit. This standard was drafted by the First Film and Guangzhou Magnetic Material Chemical Factory of the Ministry of Chemical Industry. Standard exchange network mmabmsoiccn various standard industry data free download 13
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Determination of volatiles in Y·Fe2O3 magnetic powder
Subject content and scope of application
This standard specifies the method for determining volatiles in Y·Fe2O3 magnetic powder for magnetic recording. HG/T2347.4—92
This standard is applicable to the determination of volatiles in Fe2O3 magnetic powder and modified Y·Fc,O3 magnetic powder for magnetic recording. Method summary
Dry the Fe,0 magnetic powder sample to be tested at 105±2℃ to constant weight, and calculate its volatile matter. 3 Instruments
3.1 Constant temperature drying oven: can be set at 105±2℃; 3.2 Balance: reading accuracy is 0.0001g, maximum load is 200g. 3.3 Dryer: filled with effective desiccant;
3.4 Weighing bottle: flat
Measurement steps
Take at least two samples for parallel measurement. Take 10±1g:Fe,0, magnetic powder sample (accurate to 0.0001g) and evenly spread it on the bottom of a weighing bottle (3.4) that has been weighed at 105±2℃ in advance, cover it with a lid, weigh the total amount (accurate to 0.0001g), then put the bottle cap upright at the bottle mouth, put it in a constant temperature drying oven (3.1) at 105±2℃, keep it for 2h, take it out and immediately cover it, transfer it to a desiccator (3.3) to cool to room temperature, weigh it (accurate to 0.0001g), heat it again for at least 30min, cool it in the desiccator (3.3), and weigh it: repeat this operation until the difference between two consecutive weighings does not exceed 0.005g, and record the lower weighing value. Calculation of the test results
The mass percentage of volatile matter (X) is calculated as follows: X
Where: mo—mass of the sample, g
m—mass of the dried sample, g.
6 Allowable difference
The allowable difference of the parallel test results of this method is less than 10%X100 of the higher valuebzxZ.net
Take the arithmetic mean of the parallel test results as the test result, and report it accurately to the second decimal place. Approved by the Ministry of Chemical Industry of the People's Republic of China on June 1, 199212
Standard Video Network wmbzmon.com Various American Standard Industry Data Free Download1993-03-01Implementation
Additional Notes:
HG/T2347.4-92
This standard is proposed by the Science and Technology Department of the Ministry of Chemical Industry of the People's Republic of China. This standard is under the jurisdiction of the Ministry of Chemical Industry's magnetic recording material standardization technology unit. This standard was drafted by the First Film and Guangzhou Magnetic Material Chemical Factory of the Ministry of Chemical Industry. Standard exchange network mmabmsoiccn various standard industry data free download 13
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 1542-2005 Lead brass rods and wires for watches
- HG 3322-1981 Determination of permanent deformation of vulcanized rubber (modulus tester method)
- HG/T 2634-1994 Photographic Chemical Hardener H-11
- NY 664-2003 Technical requirements for electronic controllers for micro hydroelectric power generation equipment
- GB/T 21569-2008 Dangerous goods - Test method for top lift of large packaging
- GB/T 5009.18-2003 Determination of fluoride in food
- JB/T 9163.9-1999 Dimensions of gear shaping cutter sockets
- SJ 20578-1996 General specification for blocking communication jammers
- JB/T 7948.2-1999 Chemical analysis methods for melting fluxes - Determination of manganese oxide content by potentiometric titration
- SL 187-1996 Technical Specification for Water Sampling SL 187-96
- GB/T 4812-1995 Special grade logs
- CJJ 60-1994 Technical regulations for operation, maintenance and safety of urban sewage treatment plants
- GB 50164-1992 Concrete quality control standard
- GB/T 4802.2-1997 Textiles--Test for pilling of fabrics--Martindale method
- CB/T 3936-2001 Technical requirements for repair of hydraulic components for engineering vessels
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com