JB/T 2205-2000 Pressure reducing valve structure length
time:
2024-08-12 09:05:26
- JB/T 2205-2000
- in force
Standard ID:
JB/T 2205-2000
Standard Name:
Pressure reducing valve structure length
Chinese Name:
减压阀结构长度
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
2000-04-24 -
Date of Implementation:
2000-10-01
Standard ICS number:
Fluid Systems and General Parts >> 23.080 PumpsChina Standard Classification Number:
Machinery>>General Parts>>J16 Valve
alternative situation:
JB 2205-1977
Skip to download
Summary:
JB/T 2205-2000 JB/T 2205-2000 Pressure reducing valve structure length JB/T2205-2000 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
JB/T2205-20H0
Reducing pressure valve
Face-to-face dimensions
2U00-04-24 Issued
State Machinery Industry Bureau
2000-10-01 Implementation
JB/2205—20
This standard is the revision of the JB/2205—20
. The original standard is revised as follows: The main differences between this standard and JB/2205—20
are as follows: 1. The nominal lift of valve 1 is 1.6MPa and 2.5MPa, and the nominal diameter is DN200, DN250, DN30U, etc. The station length is 550, 600mm, and the leakage structure can be selected. Select the appropriate structure length. 2. Make appropriate adjustments to the structure length tolerance and reduce it by (0.3-0.5) mm. This standard replaces 2205-77 from the date of this standard. This standard will be submitted to the National Standardization Technical Committee for approval. The minor revision units are: Shenyang Yanmen Research Institute and Shanghai General Research Institute. The main revision persons of this standard are: Zheng Yunhai and Kong Tilong. Scope
Machinery Industry Standards of the People's Republic of China
Pressure Structure Length
Redueing pressare Velve
Face-lo-facedimensions
This standard strictly specifies the structural length of flange-connected metal valves. JB/2205-2000
This standard is applicable to nominal pressure PN1.0~6.4MPa, nominal diameter DN20~300mm: ". Operating temperature ratio 1425:1 industrial valves. The staggered length of the reverse-connected filter valve can refer to the technical standard for quick operation. 2 Terms
Structural length: The distance between the two perpendicular magnetic channel axis planes of the valve body, 3 Dimensions and tolerances
3.1 Structural length is specified in Table 1.
Nominal diameter
Structural average length is specified in Table 2.
Approved by the State Machinery Industry Bureau on April 24, 2000 to
Nominal quality PNMPs
1 6 and 2.5bzxz.net
Structural length
4.0 and 6.4
20(00-10-01 implementation
140-2l
220-300
310-400
450-550
56--65G
7x-8(K)
JB/T 2205—2000
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T2205-20H0
Reducing pressure valve
Face-to-face dimensions
2U00-04-24 Issued
State Machinery Industry Bureau
2000-10-01 Implementation
JB/2205—20
This standard is the revision of the JB/2205—20
. The original standard is revised as follows: The main differences between this standard and JB/2205—20
are as follows: 1. The nominal lift of valve 1 is 1.6MPa and 2.5MPa, and the nominal diameter is DN200, DN250, DN30U, etc. The station length is 550, 600mm, and the leakage structure can be selected. Select the appropriate structure length. 2. Make appropriate adjustments to the structure length tolerance and reduce it by (0.3-0.5) mm. This standard replaces 2205-77 from the date of this standard. This standard will be submitted to the National Standardization Technical Committee for approval. The minor revision units are: Shenyang Yanmen Research Institute and Shanghai General Research Institute. The main revision persons of this standard are: Zheng Yunhai and Kong Tilong. Scope
Machinery Industry Standards of the People's Republic of China
Pressure Structure Length
Redueing pressare Velve
Face-lo-facedimensions
This standard strictly specifies the structural length of flange-connected metal valves. JB/2205-2000
This standard is applicable to nominal pressure PN1.0~6.4MPa, nominal diameter DN20~300mm: ". Operating temperature ratio 1425:1 industrial valves. The staggered length of the reverse-connected filter valve can refer to the technical standard for quick operation. 2 Terms
Structural length: The distance between the two perpendicular magnetic channel axis planes of the valve body, 3 Dimensions and tolerances
3.1 Structural length is specified in Table 1.
Nominal diameter
Structural average length is specified in Table 2.
Approved by the State Machinery Industry Bureau on April 24, 2000 to
Nominal quality PNMPs
1 6 and 2.5bzxz.net
Structural length
4.0 and 6.4
20(00-10-01 implementation
140-2l
220-300
310-400
450-550
56--65G
7x-8(K)
JB/T 2205—2000
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 4498-1997 Determination of ash content in rubber
- QX/T 499-2019 Technical specifications for lightning protection of road traffic electronic monitoring systems
- HG 2264-1992 Types, main dimensions and markings of mechanical seals for kettles
- GB 18468-2001 Hygienic standard for p-dichlorobenzene in indoor air
- GB/T 6379.1-2004 Accuracy(trueness and precision)of measurement methods and results?Part 1:General principles and definitions
- GB/T 2978-1997 Passenger car tire series
- YY/T 0457.3-2003 Characteristics of optoelectronic X-ray image intensifiers for medical electrical equipment Part 3: Determination of brightness distribution and non-uniformity
- GB 4793.5-2001 Particular requirements for hand-held probes for safe electrical measurements and tests on electrical equipment for measurement, control and laboratory use
- GB/T 5757-1986 Determination of water content of ion exchange resin
- NY/T 788-2004 Guideline on pesticide residue trials
- GB 17914-1999 Specifications for storage and preservation of combustible and explosive goods
- JB/T 502-1991 Spiral discharge sedimentation centrifuge type and basic parameters
- GB/T 8478-2003 Aluminum alloy door
- GB/T 29193-2012 Alphabetic code for incoterms
- JJG 124-2005 Verification Regulation of Amperemeters Voltmeters Wattmeters and Ohmmeters
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com