GB/T 17847-1999 Electric fans for small boats
time:
2024-08-12 11:21:24
- GB/T 17847-1999
- in force
Standard ID:
GB/T 17847-1999
Standard Name:
Electric fans for small boats
Chinese Name:
小艇 电动风机
Standard category:
National Standard (GB)
-
Date of Release:
1999-08-31 -
Date of Implementation:
2000-06-01
Standard ICS number:
Shipbuilding and offshore structures >> 47.080 Small vesselsChina Standard Classification Number:
Ship>>Ship Equipment>>U37 Small Ship Equipment
publishing house:
China Standards PressISBN:
155066.1-16365Publication date:
2000-06-01
Release date:
1999-08-31Review date:
2004-10-14Drafting Organization:
China State Shipbuilding Corporation Seventh Institute No. 708Focal point Organization:
National Technical Committee for Small Boat StandardizationPublishing Department:
State Administration of Quality and Technical SupervisionCompetent Authority:
China State Shipbuilding Corporation

Skip to download
Summary:
This standard specifies the requirements for fans used in engine rooms, galleys and other spaces on small boats that require mechanical ventilation, and describes the test methods for measuring fan air volume. This standard applies to direct current (dc) fans with a rated voltage less than 50V. Fans can be centrifugal or axial. GB/T 17847-1999 Electric fans for small boats GB/T17847-1999 Standard download decompression password: www.bzxz.net

Some standard content:
ICS 46.0HU
National Standard of the People's Republic of China
GB/T 178471999
irl1 1S0 9097:1991
Electric Fanswww.bzxz.net
Small electric fans-Electric fans1999-08-31 Issued
2000-06-01 Implementation
National Quality and Technical Bureau
GR/T17841999
This standard adopts 1509097, 1991 Small electric fans
This standard 6. The previous\undelivered S5%0 has been issued, 5901:17 Industrial fans\This standard is mainly issued by China Shipbuilding Industry Corporation. This standard is owned by Weizhongyuan Shipbuilding Industry Corporation. This standard was drafted by: China State Shipbuilding Corporation No. 78 Research Institute, China Shipbuilding Industry Corporation EC Institute. The main drafters of the standard are: Jiang Hui, Sheng Zhen, Zhang Kesheng, Sui Zai Luo. TIBT17847-1099
The International Organization for Standardization (IOT) is a worldwide association of national standard certification bodies (member institutes), which formulates international standards through technical committees. All members of the committee who have paid a technical fee have the right to participate in this work. International non-governmental organizations that have joint projects with the government may also participate in this work. They are committed to cooperating closely with the International Electrotechnical Exchange Commission (IEC) on all issues of electrotechnical standardization. The technical committee shall adopt the national standard for the purpose of marking the product, and the Council shall receive the standard and distribute it to all members for review and approval. The international standard ISOI7 is defined by the JSUTCIS Technical Committee. 1 Scope
National Standard of the People's Republic of China
Small Boat Electric Fan
Smll eraft Rlectrdcal fans
CB41999
1d159097.1991
This standard sets the requirements for the ventilation of small mechanical equipment on board ships, kitchens and other places, and explains the test methods for measuring the ventilation of fans.
This standard is applicable to low voltage DC (..) fans. The fans can be high-core or axial flow. 2 Reference standards
The provisions of the following standards in front of the color are cited in this standard to constitute the text of this standard. When the version is marked, the versions shown are valid. All marked versions will be revised. The following standards are used to update the performance of this standard. 1508:.9 Protection of small postal electrical equipment against ignition of gases around it AMCA21,1!&5ASIIRAE5::1J85 duct fan rated laboratory test method 8-81; general purpose wine fan part =: performance follow-up test method [N21163-1:35 based on the machine energy brush stop standard characteristics by line 3121163-2:955 ventilation function measurement standard test will be platform FXCCU: shell and then add points and pull the fan and then the fan in the platform book air volume test version out of the main description method
3 fixed text
This standard to improve the following meanings,
3 points of natural installation-Frotceteddevice will meet the requirements of 1S8RJe installation: S door 46 agent describes the corresponding test outline) 32 circuit pressure orinal :l
The second pass band uses vertical current pressure, such as 6, 12, 24 and 32V.4 First pole requirements
1.1 The fan should be designed to be able to operate continuously under the standard voltage of 120, 4.2 The wind seal should comply with the intermittent ignition requirements of 15) 3346. 4.3 The wind resistance of the fan should be determined based on its performance. The wind benefit of the fan should be measured and the performance curve should be obtained. 4.4 The fan blades or rotor and the outer materials should be disassembled to prevent fire from occurring when they collide with each other. 1: Air movement control l Note 30UirilivAlinnJeighrs[Con4,tS.A National Quality and Technical Supervision Week 19990831 approved 2000-06-D1 implementation
GB/T1/8471999
4.5 The moving parts of the fan shall be protected or equipped with protective covers to protect personnel from injury. The fan housing shall be equipped with drains to prevent water accumulation in the installation position. If it is determined that the design of the moving parts of the fan is not suitable, additional protection shall be installed. 4.6 The equipment to be installed on the fan shall be protected. 2.7 The parts of the fan shall be selected so that no electrical corrosion will occur in the presence of seawater: 4.8 The parts of the fan shall be able to withstand the pressure of seawater. 4.9 Each fan shall be equipped with a fan performance cable installation manual (6.2). 5 Electrical requirements
5.1 The fan shall be a two-wire type. The cable and the return cable shall be insulated from the motor. 5.2 The conductor used for the connection shall be a relatively long cable. Note: The requirements for low-power electrical basic quality shall be determined in the original standard. 53 If there is an external effective wiring strap, the test terminal shall be designed to be a natural contact element between the two main power components.
5.4 The fan has an external motor cable. The specification of these cables shall meet the requirements of the transmission power. The nominal cable shall not be less than 1m. The insulation of the wire is suitable for use in the environment of 20% nominal current and eC.
5.5 The following measures should be taken to prevent the fan from continuing to be in a rotor stuck state out of specification: Overall overcurrent protection
: The value of the protection should be within the rated value to ensure that the fan is in a motorized state; Overcurrent protection: - The maximum speed at which the fan rotates must not exceed 151% when the ambient temperature is maintained at 75°C, and it must be especially careful to avoid combustion, burning or reverse rotation.
6 Fan Rating
6.1 Fans should be rated with electrical ratings (V) and amperes () or with rated W). 6.2 The rated ratings required should be calibrated using the following methods given in the relevant standards. Before calibration, some national standards are required. The 1S80 standard is combined with these standards. 6.2.1 Fans with discrete air inlets and outlets (class B are mostly the following standard screens); AMCA210.1985/ASHRAE5185. Figure 9 to Medical-2 Figure 2
---2413-1. Figure 2, test bench layout 2, installed NF X10 2G.
6.2.2 For fans with ducted air inlet and front-end outlet, please refer to the following new standards: AMCA210.U85/A5HRAEb-:?85, Figure 13 Figure 1: 848-Figure 28 South 8
DIN111, Type A 1 installed in B:
[IN 24163-2.↓.
6.2.3 For fans with ducted air outlet, please refer to the following standards: AMCA211935/ASRAF51.1965 Figure 9.~Figure 3BS1, Figure 29 to Figure 29e)
[>24163-2.
Note: The area of the mountain is selected!
6.3 The following are the pictures of the fan:
GB/T17847-*999
a When installing a fan, make sure that all cooling meters are properly controlled:) During the whole test, the fan is operated at 13 nominal pressure;) During the whole test, the starting voltage of the machine is the nominal voltage! Calibrate the recorded air flow factor in the test to the standard density of 1.2kB/m1. The total pressure should be 3.2kB/m1. The air flow should be marked with the following information: 7 Marking
7.1 The following information should be marked permanently and clearly on the fan:) Manufacturer or special mark name or city mark! h) Type or model identification:
e) to year (with fixed code
C) similar to the standard () dynamic safety language (A) or old with special V) and watt [W] represents the monthly gas rating. 7.2 degrees in an appropriate way to mark GH/door 17847 (131130) 097) and \marine\, etc., indicating that the fan meets the standard:
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
GB/T 178471999
irl1 1S0 9097:1991
Electric Fanswww.bzxz.net
Small electric fans-Electric fans1999-08-31 Issued
2000-06-01 Implementation
National Quality and Technical Bureau
GR/T17841999
This standard adopts 1509097, 1991 Small electric fans
This standard 6. The previous\undelivered S5%0 has been issued, 5901:17 Industrial fans\This standard is mainly issued by China Shipbuilding Industry Corporation. This standard is owned by Weizhongyuan Shipbuilding Industry Corporation. This standard was drafted by: China State Shipbuilding Corporation No. 78 Research Institute, China Shipbuilding Industry Corporation EC Institute. The main drafters of the standard are: Jiang Hui, Sheng Zhen, Zhang Kesheng, Sui Zai Luo. TIBT17847-1099
The International Organization for Standardization (IOT) is a worldwide association of national standard certification bodies (member institutes), which formulates international standards through technical committees. All members of the committee who have paid a technical fee have the right to participate in this work. International non-governmental organizations that have joint projects with the government may also participate in this work. They are committed to cooperating closely with the International Electrotechnical Exchange Commission (IEC) on all issues of electrotechnical standardization. The technical committee shall adopt the national standard for the purpose of marking the product, and the Council shall receive the standard and distribute it to all members for review and approval. The international standard ISOI7 is defined by the JSUTCIS Technical Committee. 1 Scope
National Standard of the People's Republic of China
Small Boat Electric Fan
Smll eraft Rlectrdcal fans
CB41999
1d159097.1991
This standard sets the requirements for the ventilation of small mechanical equipment on board ships, kitchens and other places, and explains the test methods for measuring the ventilation of fans.
This standard is applicable to low voltage DC (..) fans. The fans can be high-core or axial flow. 2 Reference standards
The provisions of the following standards in front of the color are cited in this standard to constitute the text of this standard. When the version is marked, the versions shown are valid. All marked versions will be revised. The following standards are used to update the performance of this standard. 1508:.9 Protection of small postal electrical equipment against ignition of gases around it AMCA21,1!&5ASIIRAE5::1J85 duct fan rated laboratory test method 8-81; general purpose wine fan part =: performance follow-up test method [N21163-1:35 based on the machine energy brush stop standard characteristics by line 3121163-2:955 ventilation function measurement standard test will be platform FXCCU: shell and then add points and pull the fan and then the fan in the platform book air volume test version out of the main description method
3 fixed text
This standard to improve the following meanings,
3 points of natural installation-Frotceteddevice will meet the requirements of 1S8RJe installation: S door 46 agent describes the corresponding test outline) 32 circuit pressure orinal :l
The second pass band uses vertical current pressure, such as 6, 12, 24 and 32V.4 First pole requirements
1.1 The fan should be designed to be able to operate continuously under the standard voltage of 120, 4.2 The wind seal should comply with the intermittent ignition requirements of 15) 3346. 4.3 The wind resistance of the fan should be determined based on its performance. The wind benefit of the fan should be measured and the performance curve should be obtained. 4.4 The fan blades or rotor and the outer materials should be disassembled to prevent fire from occurring when they collide with each other. 1: Air movement control l Note 30UirilivAlinnJeighrs[Con4,tS.A National Quality and Technical Supervision Week 19990831 approved 2000-06-D1 implementation
GB/T1/8471999
4.5 The moving parts of the fan shall be protected or equipped with protective covers to protect personnel from injury. The fan housing shall be equipped with drains to prevent water accumulation in the installation position. If it is determined that the design of the moving parts of the fan is not suitable, additional protection shall be installed. 4.6 The equipment to be installed on the fan shall be protected. 2.7 The parts of the fan shall be selected so that no electrical corrosion will occur in the presence of seawater: 4.8 The parts of the fan shall be able to withstand the pressure of seawater. 4.9 Each fan shall be equipped with a fan performance cable installation manual (6.2). 5 Electrical requirements
5.1 The fan shall be a two-wire type. The cable and the return cable shall be insulated from the motor. 5.2 The conductor used for the connection shall be a relatively long cable. Note: The requirements for low-power electrical basic quality shall be determined in the original standard. 53 If there is an external effective wiring strap, the test terminal shall be designed to be a natural contact element between the two main power components.
5.4 The fan has an external motor cable. The specification of these cables shall meet the requirements of the transmission power. The nominal cable shall not be less than 1m. The insulation of the wire is suitable for use in the environment of 20% nominal current and eC.
5.5 The following measures should be taken to prevent the fan from continuing to be in a rotor stuck state out of specification: Overall overcurrent protection
: The value of the protection should be within the rated value to ensure that the fan is in a motorized state; Overcurrent protection: - The maximum speed at which the fan rotates must not exceed 151% when the ambient temperature is maintained at 75°C, and it must be especially careful to avoid combustion, burning or reverse rotation.
6 Fan Rating
6.1 Fans should be rated with electrical ratings (V) and amperes () or with rated W). 6.2 The rated ratings required should be calibrated using the following methods given in the relevant standards. Before calibration, some national standards are required. The 1S80 standard is combined with these standards. 6.2.1 Fans with discrete air inlets and outlets (class B are mostly the following standard screens); AMCA210.1985/ASHRAE5185. Figure 9 to Medical-2 Figure 2
---2413-1. Figure 2, test bench layout 2, installed NF X10 2G.
6.2.2 For fans with ducted air inlet and front-end outlet, please refer to the following new standards: AMCA210.U85/A5HRAEb-:?85, Figure 13 Figure 1: 848-Figure 28 South 8
DIN111, Type A 1 installed in B:
[IN 24163-2.↓.
6.2.3 For fans with ducted air outlet, please refer to the following standards: AMCA211935/ASRAF51.1965 Figure 9.~Figure 3BS1, Figure 29 to Figure 29e)
[>24163-2.
Note: The area of the mountain is selected!
6.3 The following are the pictures of the fan:
GB/T17847-*999
a When installing a fan, make sure that all cooling meters are properly controlled:) During the whole test, the fan is operated at 13 nominal pressure;) During the whole test, the starting voltage of the machine is the nominal voltage! Calibrate the recorded air flow factor in the test to the standard density of 1.2kB/m1. The total pressure should be 3.2kB/m1. The air flow should be marked with the following information: 7 Marking
7.1 The following information should be marked permanently and clearly on the fan:) Manufacturer or special mark name or city mark! h) Type or model identification:
e) to year (with fixed code
C) similar to the standard () dynamic safety language (A) or old with special V) and watt [W] represents the monthly gas rating. 7.2 degrees in an appropriate way to mark GH/door 17847 (131130) 097) and \marine\, etc., indicating that the fan meets the standard:
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB 1805.3-1993 Industrial protease preparations
- QB/T 1425-1991 Technical requirements for ZWC super calender
- HG/T 2467.5-1996 Specification for the preparation of pesticide suspension product standards
- GB 7930-1987 1:500, 1:1000, 1:2000 topographic map aerial photogrammetry industry specifications
- JB/T 9005.1-1999 Rope groove section of cast pulley for crane
- RB/T 242.3-2018 Requirements for green products certification bodies—Part 3:Renewable energy utilization
- JB/T 8474-1996 Trademark die-cutting machine
- GBZ 140-2002 Standard for cosmic radiation control for aircrew
- GB 4404.4-1999 Grain Crop Seeds Buckwheat
- GB 4706.2-1996 Special requirements for safety electric irons for household and similar electrical appliances
- GB 5092-1985 Technical requirements for inductive safety devices for presses
- GBJ 123-1988 Geotechnical test method standard GBJ123-88
- JB/T 9955.2-1999 Radial forging machine accuracy
- GB 16221-1996 Hygienic standard for hydrazine in workshop air
- GB 12265.1-1997 机械安全 防止上肢触及危险区的安全距离
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]