GB 16186-1996 Hygienic standard for cypermethrin in workshop air

time: 2024-08-06 06:55:44
  • GB 16186-1996
  • in force

Basic Information

standard classification number

  • Standard ICS number:

    Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplace
  • China Standard Classification Number:

    Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene

associated standards

Publication information

Other Information

  • Release date:

    1996-04-03
  • Review date:

    2004-10-14
  • Drafting Organization:

    Institute of Labor Health, Chinese Academy of Preventive Medicine
  • Focal point Organization:

    Ministry of Health
  • Publishing Department:

    State Administration of Technical Supervision Ministry of Health of the People's Republic of China
  • Competent Authority:

    Ministry of Health
Introduction to standardsDescription (Translated English) / download

Skip to download

Summary:

This standard specifies the maximum permissible concentration of cypermethrin in workshop air and its monitoring and testing methods. This standard is applicable to all types of enterprises that produce, repack and use cypermethrin. GB 16186-1996 Hygienic standard for cypermethrin in workshop air GB16186-1996 Standard download decompression password: www.bzxz.net
Standard contentStandard content

Some standard content:

National Standard of the People's Republic of China
Health standard for deltamethrin in the air of workplace
Health standard for deltamethrin in the air of workplace1 Subject content and scope of application
This standard specifies the maximum allowable concentration of deltamethrin in the air of workplace and its monitoring and inspection methods. This standard is applicable to all types of enterprises that produce, repack and use deltamethrin. 2 Hygiene requirements
The maximum allowable concentration of deltamethrin in the air of workplace is 0.03mg/m3. 3 Monitoring and inspection methodsWww.bzxZ.net
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. 4 Supervision and implementation
Health and epidemic prevention agencies at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996 388 GB 16186-1996 Implementation on September 1, 1996 A1 Principle GB16186-1996 Appendix A Gas Chromatography (Supplement) Deltamethrin in air is adsorbed by polyurethane foam and extracted with n-hexane. The extract is separated by 0V-101 column and detected by electron capture detector. Retention time is qualitative and peak height is quantitative. The detection limit of this method is 0.002μg/ml. Liquid sample. A2 Instruments
A2.1 Sampler: Aluminum cylinder, inner diameter 24mm, length 79mm; a glass tube with inner diameter 20mm, length 80mm is installed inside, and the glass tube can hold four pieces of foam plastic (see the figure below). 1 Sampling head; 2--Sampling tube (with foam plastic inside); 3--Base Sampler
A2.2 Polyurethane foam plastic: Cut into Φ24mm×18mm cylindrical small pieces, extract with n-hexane for 8h, and use after drying. A2.3 Soxhlet extractor, 50ml.
A2.4 Micro syringe, 10μl.
A2.5 Gas chromatograph, 63Ni electron capture detector. A3 Reagents
A3.1 Deltamethrin, content above 98%. A3.2 n-hexane, analytical grade.
A3.30V-101, chromatographic stationary liquid.
A3.4ChromosorbWAWDMCS carrier, 60-80 mesh. A4Sampling
Put four pieces of foam plastic into the glass sampling tube, connect the flow meter and the vacuum pump, and extract 50L of air at a speed of 2-10L/min. A5Analysis steps
A5.1Chromatographic conditions
a. Chromatographic column: 1m long, 2mm inner diameter, glass column. oV-101: ChromosorbWAWDMCS carrier = 3:10o. Column temperature: 240C.
b. Vaporization chamber temperature: 250C.
Detection chamber temperature: 310℃.
Carrier gas (high purity nitrogen): 30ml./min.
A5.2 Drawing of standard curve
GB16186-1996
Use n-hexane to prepare three concentrations of 0.025, 0.050 and 0.100μg/mL of deltamethrin standard solution, take 2μL of each solution for injection, measure retention time and peak height, repeat 3 times for each concentration, take the average of peak height, plot the concentration of deltamethrin against peak height, draw a standard curve, and use retention time as a qualitative indicator.
A5.3 Sample analysis
After sampling, put the first two pieces and the last two pieces of foam plastic into a 50mL Soxhlet extractor, extract with n-hexane for 4h, and make the volume 50ml. Then take 2ul of sample for injection, use retention time for qualitative analysis and peak height for quantitative analysis. A6 Calculation
Concentration of cypermethrin in the air, mg/m; Where: X
C—Cypermethrin concentration found by standard curve, μg/mL; V. —Sampling volume under standard conditions, L. A7 Precautions
A7.1 Samples should be analyzed in time (within one week). If the temperature is high, they should be kept in a cool place. A7.2 Pretreatment of foam plastics requires extraction for 8 hours before use. Additional notes:
This standard was proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine. The main drafters of this standard are Wang Shujie and He Fengsheng. (Al)
This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, which is the technical management unit entrusted by the Ministry of Health. 390
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]