
JB/T 9141.9-1999 Sampling method for flexible graphite sheets
time:
2024-08-14 12:24:28
- JB/T 9141.9-1999
- in force
Standard ID:
JB/T 9141.9-1999
Standard Name:
Sampling method for flexible graphite sheets
Chinese Name:
柔性石墨板材 取样方法
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1999-06-28 -
Date of Implementation:
2000-01-01
Standard ICS number:
Mechanical systems and general parts >> 21.140 Seals and sealing devicesChina Standard Classification Number:
Machinery>>General Parts>>J22 Seals and Sealing Devices
alternative situation:
ZB J22018-1990
Focal point Organization:
(Ministry) Packing Static Seal Standardization Technical Committee

Skip to download
Summary:
JB/T 9141.9-1999 JB/T 9141.9-1999 Sampling method for flexible graphite sheet JB/T9141.9-1999 Standard download decompression password: www.bzxz.net

Some standard content:
IC'S 21.140
Machinery Industry Standard of the People's Republic of China
JB/T9141.9—1999
Flexible Graphite Sheet
Sampling Method
Sampling mcthod for flcriblegraphite shcets1999-06-28 Issued
National Machinery Industry Bureau
2000-01-01 Implementation
13/T9141.9-19949
Sampling Method" was revised. At the same time, the original standard was revised and revised. The main technical content has not changed. This standard is replaced by ZBJ22018-90 from the date of implementation. This standard is proposed by the Technical Committee for Standardization of Fillings and Static Seals: This standard is initiated by: Hefei Tongzhou Press Research Institute, the main drafter of this standard! Zhang Qun
Machinery Industry Standard of the People's Republic of China
Flexible Graphite Sheet
Sampling Method
Sampling method for flexibir graphite gbnets This standard specifies the sampling method for flexible graphite sheets. This standard uses two flexible egg board performance test selection, 2 giant board sampling
Silver door board in the silver roll Rui Da sample,
JB/T9141.9-1599
# 24 127 1 99
width B is not less than 500mm of the plate, first cut off 50mm of the left end, and then take the same sample at the same position within the range of 0mm on both sides, and the center distance of the column piece in the direction of the plate width is not less than 1., and the corresponding edge distance in the length direction of the plate is not less than 20mm.
The center distance of the sample in the width direction of the standard material, mm; a-
One plate width, mm
For the board with a width between 300-500mm, first remove 50mm from the end, and then use the same sample pieces as shown in 2 within the range of 30mm from both sides. The center distance of the sample in the width direction of the standard material should not be less than, and the adjacent edge distance in the length direction of the standard material should not be less than 30mm:
The center distance of the sample in the upward direction of the plate is mn: 5
One material width, mm,
Approved by the State Machinery Industry Bureau on 199-06-28
Implementation of 206H-01-01bZxz.net
JB/F 5141.9—1999
For plates with a crown length B less than 300mm, cut 50mm at the end and then take a piece from the inner length of the plate with a height of 20mm on both sides.
3 Sampling of molded plate
Molded plates are taken from the packaging box. The plates taken out of the box are first cut off 20mm on each side. After burning, they are divided into two parts using the quartering method. One part is used for sample preparation and the other is reserved.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of China
JB/T9141.9—1999
Flexible Graphite Sheet
Sampling Method
Sampling mcthod for flcriblegraphite shcets1999-06-28 Issued
National Machinery Industry Bureau
2000-01-01 Implementation
13/T9141.9-19949
Sampling Method" was revised. At the same time, the original standard was revised and revised. The main technical content has not changed. This standard is replaced by ZBJ22018-90 from the date of implementation. This standard is proposed by the Technical Committee for Standardization of Fillings and Static Seals: This standard is initiated by: Hefei Tongzhou Press Research Institute, the main drafter of this standard! Zhang Qun
Machinery Industry Standard of the People's Republic of China
Flexible Graphite Sheet
Sampling Method
Sampling method for flexibir graphite gbnets This standard specifies the sampling method for flexible graphite sheets. This standard uses two flexible egg board performance test selection, 2 giant board sampling
Silver door board in the silver roll Rui Da sample,
JB/T9141.9-1599
# 24 127 1 99
width B is not less than 500mm of the plate, first cut off 50mm of the left end, and then take the same sample at the same position within the range of 0mm on both sides, and the center distance of the column piece in the direction of the plate width is not less than 1., and the corresponding edge distance in the length direction of the plate is not less than 20mm.
The center distance of the sample in the width direction of the standard material, mm; a-
One plate width, mm
For the board with a width between 300-500mm, first remove 50mm from the end, and then use the same sample pieces as shown in 2 within the range of 30mm from both sides. The center distance of the sample in the width direction of the standard material should not be less than, and the adjacent edge distance in the length direction of the standard material should not be less than 30mm:
The center distance of the sample in the upward direction of the plate is mn: 5
One material width, mm,
Approved by the State Machinery Industry Bureau on 199-06-28
Implementation of 206H-01-01bZxz.net
JB/F 5141.9—1999
For plates with a crown length B less than 300mm, cut 50mm at the end and then take a piece from the inner length of the plate with a height of 20mm on both sides.
3 Sampling of molded plate
Molded plates are taken from the packaging box. The plates taken out of the box are first cut off 20mm on each side. After burning, they are divided into two parts using the quartering method. One part is used for sample preparation and the other is reserved.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 17733.1-1999 Place name signs for urban and rural areas
- GBZ/T 150-2002 Specification for monitoring of health protection in industrial X-ray flaw detection
- JB/T 10231.18-2002 Tool Product Testing Methods Part 18: Indexable Turning Tools
- GB/T 2828.3-2008 Sampling procedures for inspection by attributes - Part 3: Skip-lot sampling procedures
- JB/T 6139-1992 Ball joint universal coupling
- JB/T 9040-1999 Belt filter press
- JB/T 2825.1-1999 Slotting machine parameters
- JB/T 7041-1993 Technical requirements for hydraulic gear pumps
- GB 2728-1981 Hygienic Standard for Braised Meat
- JB/T 8811.1-1998 Electric refueling pump 4MPa
- GBZ 42-2002 Diagnostic criteria for occupational acute carbon tetrachloride poisoning
- JB/T 2001.46-1999 Air filling valve for water system pump station (PN=20, 31.5MPa)
- GA/T 483-2004 Engineering management requirement in computer information system classified security protection
- JB/T 7908-1999 Technical requirements for powder metallurgy oil pump rotors for internal combustion engines
- HG/T 2924-1988 Food additive Ethoxyquin
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com