
GB 16184-1996 Hygienic standard for sulfuryl fluoride in workplace air
time:
2024-08-06 06:56:59
- GB 16184-1996
- in force
Standard ID:
GB 16184-1996
Standard Name:
Hygienic standard for sulfuryl fluoride in workplace air
Chinese Name:
车间空气中硫酰氟卫生标准
Standard category:
National Standard (GB)
-
Date of Release:
1996-04-03 -
Date of Implementation:
1996-09-01
Standard ICS number:
Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplaceChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
alternative situation:
Partially replaced by GBZ/T 160.33-2004
Release date:
1996-04-03Review date:
2004-10-14Drafting Organization:
Institute of Labor Health, Chinese Academy of Preventive MedicineFocal point Organization:
Ministry of HealthPublishing Department:
State Administration of Technical Supervision Ministry of Health of the People's Republic of ChinaCompetent Authority:
Ministry of Health

Skip to download
Summary:
This standard specifies the maximum permissible concentration of sulfuryl fluoride in workshop air and its monitoring and inspection methods. This standard is applicable to all types of enterprises that produce and use sulfuryl fluoride. GB 16184-1996 Hygienic Standard for Sulfuryl Fluoride in Workshop Air GB16184-1996 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Health standard for sulfuryl fluoride in the air of workplace
Subject content and scope of applicationwwW.bzxz.Net
This standard specifies the maximum allowable concentration of sulfuryl fluoride in the air of workplace and its monitoring and inspection methods. This standard applies to all types of enterprises that produce and use sulfuryl fluoride. 2 Hygiene requirements
The maximum allowable concentration of sulfuryl fluoride in the air of workplace is 20mg/m. 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. 4 Supervision and implementation
Health and epidemic prevention agencies at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996 382
GB16184--1996
Implementation on September 1, 1996
A1 Principle
GB16184-1996
Appendix A
Gas chromatography
(Supplement)
Sulfuryl fluoride in the air is separated by a polytrifluorochloroethylene wax column and detected by an electron capture detector. Retention time is qualitative and peak height is quantitative. The detection limit of this method is 1.8×10-6μg (direct injection of 0.4mL air sample). A2 Apparatus
A2.1 Syringe: 100mL, 50mL.
A2.2 Gas chromatograph: electron capture detector. A3 Reagents
A3.1 Sulfuryl fluoride.
A3.2 Polychlorotrifluoroethylene wax, chromatographic stationary liquid. A3.3401 organic carrier: 60~80 mesh.
A4 Sampling
Take a 100ml syringe and purge it with on-site air several times at the sampling site, then extract about 100mL of air sample, put on a small rubber cap, and then place the syringe vertically for analysis on the same day. 5 Analysis steps
A5.1 Chromatographic conditions
Chromatographic column: 3m long, 4mm inner diameter stainless steel column. Polychlorotrifluoroethylene wax: 401 organic carrier-2:100. Column temperature 60℃. Vaporization chamber temperature: room temperature.
Detection chamber temperature: 180℃.
d, carrier gas (high purity nitrogen): 50mL/min. A5.2 Standard curve drawing
Use a 1ml syringe to accurately measure sulfuryl fluoride gas of known concentration (1mL sulfuryl fluoride gas weighs 4.56mg under standard conditions) and inject it into a 100mL syringe. Dilute it with clean air to make 10×10-3, 30×10-\ and 50×10-3μg/mL sulfuryl fluoride standard gas, and inject 0.4mL with a 1mL syringe. Repeat three times for each concentration, take the average value of the peak height, plot the sulfuryl fluoride content against the peak height, and draw a standard curve. Retention time is a qualitative indicator. A5.3 Sample analysis
Take 0.4mL of air sample for injection. If the sample concentration is too high, dilute it with clean air or nitrogen gas for an appropriate time before injection. Use retention time for qualitative analysis and peak height for quantitative analysis.
A6 Calculation
×1000
(Al)
GB 16184-1996
Concentration of sulfuryl fluoride in the air, nig/m2; i. X--.
Sulfuryl fluoride content found on the standard curve, ug; C
Injection volume under standard conditions, mL.
Additional remarks:
This standard was proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine. The main drafters of this standard were Lü Boqin and Zeng Zhaohui. This standard was interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, the technical management unit entrusted by the Ministry of Health. 381
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Health standard for sulfuryl fluoride in the air of workplace
Subject content and scope of applicationwwW.bzxz.Net
This standard specifies the maximum allowable concentration of sulfuryl fluoride in the air of workplace and its monitoring and inspection methods. This standard applies to all types of enterprises that produce and use sulfuryl fluoride. 2 Hygiene requirements
The maximum allowable concentration of sulfuryl fluoride in the air of workplace is 20mg/m. 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. 4 Supervision and implementation
Health and epidemic prevention agencies at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996 382
GB16184--1996
Implementation on September 1, 1996
A1 Principle
GB16184-1996
Appendix A
Gas chromatography
(Supplement)
Sulfuryl fluoride in the air is separated by a polytrifluorochloroethylene wax column and detected by an electron capture detector. Retention time is qualitative and peak height is quantitative. The detection limit of this method is 1.8×10-6μg (direct injection of 0.4mL air sample). A2 Apparatus
A2.1 Syringe: 100mL, 50mL.
A2.2 Gas chromatograph: electron capture detector. A3 Reagents
A3.1 Sulfuryl fluoride.
A3.2 Polychlorotrifluoroethylene wax, chromatographic stationary liquid. A3.3401 organic carrier: 60~80 mesh.
A4 Sampling
Take a 100ml syringe and purge it with on-site air several times at the sampling site, then extract about 100mL of air sample, put on a small rubber cap, and then place the syringe vertically for analysis on the same day. 5 Analysis steps
A5.1 Chromatographic conditions
Chromatographic column: 3m long, 4mm inner diameter stainless steel column. Polychlorotrifluoroethylene wax: 401 organic carrier-2:100. Column temperature 60℃. Vaporization chamber temperature: room temperature.
Detection chamber temperature: 180℃.
d, carrier gas (high purity nitrogen): 50mL/min. A5.2 Standard curve drawing
Use a 1ml syringe to accurately measure sulfuryl fluoride gas of known concentration (1mL sulfuryl fluoride gas weighs 4.56mg under standard conditions) and inject it into a 100mL syringe. Dilute it with clean air to make 10×10-3, 30×10-\ and 50×10-3μg/mL sulfuryl fluoride standard gas, and inject 0.4mL with a 1mL syringe. Repeat three times for each concentration, take the average value of the peak height, plot the sulfuryl fluoride content against the peak height, and draw a standard curve. Retention time is a qualitative indicator. A5.3 Sample analysis
Take 0.4mL of air sample for injection. If the sample concentration is too high, dilute it with clean air or nitrogen gas for an appropriate time before injection. Use retention time for qualitative analysis and peak height for quantitative analysis.
A6 Calculation
×1000
(Al)
GB 16184-1996
Concentration of sulfuryl fluoride in the air, nig/m2; i. X--.
Sulfuryl fluoride content found on the standard curve, ug; C
Injection volume under standard conditions, mL.
Additional remarks:
This standard was proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine. The main drafters of this standard were Lü Boqin and Zeng Zhaohui. This standard was interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, the technical management unit entrusted by the Ministry of Health. 381
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 5332.3-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 3: Flat power cables for electric submersible pumps
- GB/T 2685-1981 Sliding bearings - Powder metallurgy cylindrical bearings - Types, dimensions and tolerances
- GB/T 9146-2003 Limit dimensions of common thread roughness and preferred series
- GB 18075-2000 Standard for sanitary protection distances in automobile manufacturing plants
- JGJ 82-1991 Design, construction and acceptance procedures for high-strength bolt connections in steel structures
- HG/T 2881-1997 Determination of paint stripping efficiency of paint strippers
- GB/T 5698-2001 Glossary of color terms
- YC 171-2002 Cigarette tipping paper
- GB/T 14680-1993 Air quality-Determination of carbon disulfide-Diethylamine spectrophotometric method
- GB/T 8593.1-1998 Earth-moving machinery operator control and other display symbols Part 1: General symbols
- GB/T 16266-1996 Test of packaging materials—Contact corrosivity
- GB/T 14366-1993 Acoustics-Determination of occupational noise exposure and estimation of noise-induced hearing impairment
- GB/T 8381-1987 Determination of aflatoxin B1 in feed
- GB/T 5413.7-1997 Determination of ash content in infant formula and milk powder
- JB/T 6915-1993 Test methods for refrigeration compressors used in automobile air conditioners
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com