JB/T 8861-2004 Ball valve static pressure life test procedures
time:
2024-08-14 16:20:21
- JB/T 8861-2004
- in force
Standard ID:
JB/T 8861-2004
Standard Name:
Ball valve static pressure life test procedures
Chinese Name:
球阀 静压寿命试验规程
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
2004-03-12 -
Date of Implementation:
2004-08-01
Standard ICS number:
Fluid Systems and General Parts>>Valves>>23.060.10 Ball ValveChina Standard Classification Number:
Machinery>>General Parts>>J16 Valve
alternative situation:
JB/T 8861-1999
publishing house:
Mechanical Industry PressISBN:
15111.7316Publication date:
2004-07-31
Drafting Organization:
Hefei General Machinery Research InstituteFocal point Organization:
National Valve Standardization CommitteePublishing Department:
National Valve Standardization Committee

Skip to download
Summary:
This standard specifies the test requirements, test methods, and determination of the number of static pressure life tests for industrial ball valves. JB/T 8861-2004 Ball Valve Static Pressure Life Test Procedure JB/T8861-2004 Standard download decompression password: www.bzxz.net

Some standard content:
ICS 23.060.10
Machinery Industry Standard of the People's Republic of China
JB/T 8861-2004
Replaces B88611999
Static pressure life test procedure
Ball valve-potential pressure life test rcgulation2004-03-12 Issued
2004-08-01 Implementation
: Issued by the National Development and Reform Commission of the People's Republic of China Foreword
2 Normative references
3 Technical specifications and definitions
4 Test requirements
5 Test methods
6 Determination of pressure life test number
6.. Termination test
6.2 Static pressure life test data
Record A (Informative Appendix) Test record
Figure! Static life test system principle
Table A1 Ball static life test data record
JB/T8861-2004
JB/R861-2004
This standard is a revision of 1B/T861-1999 Ball static pressure life test specification. Compared with BT8861-1999, the main changes are: increased scope of application of the standard: applicable to static pressure life tests of various types of balls; increased application standards;
requirements for the ball door opening specification, test pressure, test pressure difference, torque control, etc. in the test requirements The content has been modified: the operation adjustment of the test method has been supplemented and revised. This standard replaces JB 8861-1999.
The test method of the standard is a reference appendix.
The standard is proposed by China Machinery Industry Federation: the National Standardization Technical Committee (SAC188) is responsible for this standard. The drafting unit of this standard is: General Machinery Research Institute of China. The main drafters of this standard are: Wang Xiaogou, Liu Xiaoshou, Zheng Qinglun. The previous versions replaced by this standard are: JB/2246-1985B/T686-1999
1 Scope
Static pressure life test procedures for ball valves
IB/T8861-2004
This standard defines "Industrial ball valves The test requirements and test methods of the positive life test, and the determination of the number of static life tests. This standard is applicable to the static pressure life test of the nominal force PN% 0.0MPa ball width. 2 Normative referenced documents || TT || The clauses in the following documents become the clauses of this standard through reference in this standard. For any cited document with a date, all subsequent amendments (excluding errors) and revisions are not applicable to this standard. However, all parties that have reached an agreement on this standard are encouraged to study whether the new version of this document can be used. For any undated application document, its latest version shall apply to this standard. GT13937—1992 Pressure test for doors (N9[05208:1982) JB/192—1999 Inspection and testing of doors 3 Terminology and definitions
The following terms and definitions apply to this standard.
Polential pressure life test Under laboratory conditions, the valve is subjected to a test of a cycle from full to full closure when subjected to a variable medium pressure. 3.2
Number of static pressure life test dmeofpatentinlpressurelifetest The total number of cycles of closing and closing that can maintain the performance required by the standard. 4 Test requirements
4.1 The sealing performance of the ball net to be subjected to the pressure life test shall comply with the requirements of (B/13927 or JBT9092. 4.2 Test of static pressure life test. The system schematic diagram is shown in Figure 1. Area
1——In Fudong, 2 original force gauge: 3—pressure limit; 4—water system: 5
gas system: that is, pressure gauge:
—microcomputer purchase:—micro test valve: 9
read after pressure gauge: 10
valve shop control reading, -
Figure 1 Static pressure test system principle
embedded pressure relief calibration valve.
JB/T886t-—2004www.bzxz.net
4.3 The test medium is filtered water: If air is needed as the test medium, the internal opening difference shall be controlled according to the set pressure of the valve during the test. 4.4 Regardless of the force used to operate the ball valve, when conducting the static pressure life test, the operating device it is equipped with shall be subjected to the opening and closing cycle test together with the valve. The handle (wheel) directly drives the valve or the manually operated ball valve driven by the worm gear reduction structure; the handle (wheel) or the sub-wheel of the worm gear reduction mechanism of the ball valve shall be driven by the driving mechanism of the life test machine: the ball valve driven by electric, hydraulic, pneumatic or other electric and pneumatic actuating devices shall be driven by the operating device it is equipped with to conduct the opening and closing cycle test. 4.5 During the static pressure life test, the ball valve starts from the fully closed sealing position, and the opening degree should reach 1DD% of its actual opening degree. 1.6 During the static life test, the body cavity should be filled with medium and pressurized from the open position to the closed position, and the medium pressure is 9%~10% of the nominal pressure of the valve: after reaching the closed position, the outlet of the ball valve releases the medium pressure. It is required to open under the pressure difference of the test medium. If the ball valve has a rated pressure drop requirement, the rated pressure difference should be used as the test stop difference during the test: 4.7 During the test, the opening position should be controlled, and the repeated deviation of the stroke position should be less than 1%. 4.8 During the test, the ball valve should be operated according to the maximum opening and closing torque obtained by the ball operation test. The operating torque should not exceed the torque required by the tightening hand wheel of the ball valve or the operating torque specified in the product standard. The repeated deviation of the operating torque should be less than 5%. 4.9 During the static pressure life test, according to the characteristics of the sealing material, the sealing performance and operating force should be checked every 300~50 opening and closing changes. If the sealing performance is qualified, continue the test: For manually operated ball valves, if the operating torque changes, the ball valve operated by other mechanisms can be adjusted manually. 4.1 When the ball valve has flow requirements, it should be installed according to the required flow. 4.11 The number of static pressure life tests should be recorded by the signal provided by the travel switch of the life test machine or electric, pneumatic or other electric-pneumatic linkage devices, and recorded by an electric stimulator. 5 Test method
5.1 Install the ball valve and determine the position when closing the seal. 5.2 Under the condition of nominal pressure differential or fixed differential, use a force measuring wrench to measure the maximum operating torque when opening and closing the ball. Test three times and record the data. Take the maximum value as the torque value of the drive mechanism of the static pressure life test cover: 5.3 Adjust the opening and closing position and output torque of the drive mechanism. 5.4 After 301~500 opening and closing cycles, check the sealing condition. If the operating torque changes, adjust the output torque of the drive mechanism to meet the sealing requirements. If it does not meet the requirements of 4.8 of this standard, continue the test. 6 Determination of static pressure life test times
6.1 Test prohibited
When the following situations occur, the test should be stopped: a) During the sealing test inspection, the sealing performance cannot meet the standard requirements; b) The wide rod packing is not greased, the foot body and other parts are leaking; c) The parts such as the shaft sleeve cannot be normally operated or the opening and closing spring moment changes greatly, which does not meet the requirements of 4.8 of this standard.
6.2 Static pressure life test times
6.2.! After reaching the required test times, when the performance of the device meets the standard requirements, this test number is the static life test number. 6.2.2 If any undesirable situation or performance does not meet the standard requirements during the test period, the number of opening and closing of the ring corresponding to the last inspection shall be the number of static pressure survival tests.
Main unit
Product unit
Product name
Public relations
Appendix A
Special material appendix
Test record
Table A.1 Ball static pressure life test data record Record the model, specification and sealing range before the test. Ensure the sealing performance of the structure is carried out in accordance with the standard test. Test personnel: Under the test determination value Pa, cut the sealing performance of the furnace and record the overall working torque. J/T 8861..2004
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of China
JB/T 8861-2004
Replaces B88611999
Static pressure life test procedure
Ball valve-potential pressure life test rcgulation2004-03-12 Issued
2004-08-01 Implementation
: Issued by the National Development and Reform Commission of the People's Republic of China Foreword
2 Normative references
3 Technical specifications and definitions
4 Test requirements
5 Test methods
6 Determination of pressure life test number
6.. Termination test
6.2 Static pressure life test data
Record A (Informative Appendix) Test record
Figure! Static life test system principle
Table A1 Ball static life test data record
JB/T8861-2004
JB/R861-2004
This standard is a revision of 1B/T861-1999 Ball static pressure life test specification. Compared with BT8861-1999, the main changes are: increased scope of application of the standard: applicable to static pressure life tests of various types of balls; increased application standards;
requirements for the ball door opening specification, test pressure, test pressure difference, torque control, etc. in the test requirements The content has been modified: the operation adjustment of the test method has been supplemented and revised. This standard replaces JB 8861-1999.
The test method of the standard is a reference appendix.
The standard is proposed by China Machinery Industry Federation: the National Standardization Technical Committee (SAC188) is responsible for this standard. The drafting unit of this standard is: General Machinery Research Institute of China. The main drafters of this standard are: Wang Xiaogou, Liu Xiaoshou, Zheng Qinglun. The previous versions replaced by this standard are: JB/2246-1985B/T686-1999
1 Scope
Static pressure life test procedures for ball valves
IB/T8861-2004
This standard defines "Industrial ball valves The test requirements and test methods of the positive life test, and the determination of the number of static life tests. This standard is applicable to the static pressure life test of the nominal force PN% 0.0MPa ball width. 2 Normative referenced documents || TT || The clauses in the following documents become the clauses of this standard through reference in this standard. For any cited document with a date, all subsequent amendments (excluding errors) and revisions are not applicable to this standard. However, all parties that have reached an agreement on this standard are encouraged to study whether the new version of this document can be used. For any undated application document, its latest version shall apply to this standard. GT13937—1992 Pressure test for doors (N9[05208:1982) JB/192—1999 Inspection and testing of doors 3 Terminology and definitions
The following terms and definitions apply to this standard.
Polential pressure life test Under laboratory conditions, the valve is subjected to a test of a cycle from full to full closure when subjected to a variable medium pressure. 3.2
Number of static pressure life test dmeofpatentinlpressurelifetest The total number of cycles of closing and closing that can maintain the performance required by the standard. 4 Test requirements
4.1 The sealing performance of the ball net to be subjected to the pressure life test shall comply with the requirements of (B/13927 or JBT9092. 4.2 Test of static pressure life test. The system schematic diagram is shown in Figure 1. Area
1——In Fudong, 2 original force gauge: 3—pressure limit; 4—water system: 5
gas system: that is, pressure gauge:
—microcomputer purchase:—micro test valve: 9
read after pressure gauge: 10
valve shop control reading, -
Figure 1 Static pressure test system principle
embedded pressure relief calibration valve.
JB/T886t-—2004www.bzxz.net
4.3 The test medium is filtered water: If air is needed as the test medium, the internal opening difference shall be controlled according to the set pressure of the valve during the test. 4.4 Regardless of the force used to operate the ball valve, when conducting the static pressure life test, the operating device it is equipped with shall be subjected to the opening and closing cycle test together with the valve. The handle (wheel) directly drives the valve or the manually operated ball valve driven by the worm gear reduction structure; the handle (wheel) or the sub-wheel of the worm gear reduction mechanism of the ball valve shall be driven by the driving mechanism of the life test machine: the ball valve driven by electric, hydraulic, pneumatic or other electric and pneumatic actuating devices shall be driven by the operating device it is equipped with to conduct the opening and closing cycle test. 4.5 During the static pressure life test, the ball valve starts from the fully closed sealing position, and the opening degree should reach 1DD% of its actual opening degree. 1.6 During the static life test, the body cavity should be filled with medium and pressurized from the open position to the closed position, and the medium pressure is 9%~10% of the nominal pressure of the valve: after reaching the closed position, the outlet of the ball valve releases the medium pressure. It is required to open under the pressure difference of the test medium. If the ball valve has a rated pressure drop requirement, the rated pressure difference should be used as the test stop difference during the test: 4.7 During the test, the opening position should be controlled, and the repeated deviation of the stroke position should be less than 1%. 4.8 During the test, the ball valve should be operated according to the maximum opening and closing torque obtained by the ball operation test. The operating torque should not exceed the torque required by the tightening hand wheel of the ball valve or the operating torque specified in the product standard. The repeated deviation of the operating torque should be less than 5%. 4.9 During the static pressure life test, according to the characteristics of the sealing material, the sealing performance and operating force should be checked every 300~50 opening and closing changes. If the sealing performance is qualified, continue the test: For manually operated ball valves, if the operating torque changes, the ball valve operated by other mechanisms can be adjusted manually. 4.1 When the ball valve has flow requirements, it should be installed according to the required flow. 4.11 The number of static pressure life tests should be recorded by the signal provided by the travel switch of the life test machine or electric, pneumatic or other electric-pneumatic linkage devices, and recorded by an electric stimulator. 5 Test method
5.1 Install the ball valve and determine the position when closing the seal. 5.2 Under the condition of nominal pressure differential or fixed differential, use a force measuring wrench to measure the maximum operating torque when opening and closing the ball. Test three times and record the data. Take the maximum value as the torque value of the drive mechanism of the static pressure life test cover: 5.3 Adjust the opening and closing position and output torque of the drive mechanism. 5.4 After 301~500 opening and closing cycles, check the sealing condition. If the operating torque changes, adjust the output torque of the drive mechanism to meet the sealing requirements. If it does not meet the requirements of 4.8 of this standard, continue the test. 6 Determination of static pressure life test times
6.1 Test prohibited
When the following situations occur, the test should be stopped: a) During the sealing test inspection, the sealing performance cannot meet the standard requirements; b) The wide rod packing is not greased, the foot body and other parts are leaking; c) The parts such as the shaft sleeve cannot be normally operated or the opening and closing spring moment changes greatly, which does not meet the requirements of 4.8 of this standard.
6.2 Static pressure life test times
6.2.! After reaching the required test times, when the performance of the device meets the standard requirements, this test number is the static life test number. 6.2.2 If any undesirable situation or performance does not meet the standard requirements during the test period, the number of opening and closing of the ring corresponding to the last inspection shall be the number of static pressure survival tests.
Main unit
Product unit
Product name
Public relations
Appendix A
Special material appendix
Test record
Table A.1 Ball static pressure life test data record Record the model, specification and sealing range before the test. Ensure the sealing performance of the structure is carried out in accordance with the standard test. Test personnel: Under the test determination value Pa, cut the sealing performance of the furnace and record the overall working torque. J/T 8861..2004
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 15730-1995 General technical requirements for telecommunications twist pliers and shear pliers
- GB/T 5174-1985 Determination of cationic active matter in detergents - Direct two-phase titration method
- GB/Z 18890.1-2002 Cross-linked polyethylene insulated power cables with rated voltage of 220 kV (Um=252 kV) and their accessories Part 1: Power cable systems of cross-linked polyethylene insulated power cables with rated voltage of 220 kV (Um=252 kV) and their accessories?
- GB/T 18769-2003 Bulk stock electronic transaction specification
- GB/T 5271.3-1987 Data processing vocabulary Part 03 Equipment technology
- GB/T 28594-2021 Weather nowcasting
- GB/T 23701-2009 Ergonomics of human-system interaction - Specification for the process assessment of human-system issues
- GA/T 977-2012 Electronic signature of forensic and identification document
- MT/T 311-1992 Types and basic parameters of oil filters for traction hydraulic systems of coal mining machines
- HG/T 2292-1992 Annular BOP Rubber Core
- YS/T 103-2004 Energy consumption in aluminum production
- GB 4655-1984 Static electricity safety regulations for rubber industry
- YD/T 5087-2005 Acceptance specification for intelligent network equipment installation project
- QB/T 2560-2002 实验室玻璃仪器 过滤漏斗
- GB/T 15436-1995 Determination of nitrogen oxides in ambient air - Saltzman method
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com