GB/T 8812-1988 Bending test method for rigid cellular plastics
time:
2024-08-10 03:12:55
- GB/T 8812-1988
- Abolished
Standard ID:
GB/T 8812-1988
Standard Name:
Bending test method for rigid cellular plastics
Chinese Name:
硬质泡沫塑料弯曲试验方法
Standard category:
National Standard (GB)
-
Date of Release:
1988-02-01 -
Date of Implementation:
1988-07-01 -
Date of Expiration:
2008-09-01
Standard ICS number:
Rubber and plastics industry >> 83.080 PlasticsChina Standard Classification Number:
Light Industry, Cultural and Living Goods>>Daily Use Glass, Ceramics, Enamel, Plastic Products>>Y20 Daily Use Glass, Ceramics, Enamel, Plastic Products Comprehensive
alternative situation:
Replaced by GB/T 8812.1-2007Procurement status:
≡ISO 1209-76
Release date:
1988-02-13Review date:
2004-10-14Drafting Organization:
Shanghai Plastics Research InstituteFocal point Organization:
National Technical Committee for Standardization of Plastic ProductsPublishing Department:
China Light Industry FederationCompetent Authority:
China Light Industry Federation

Skip to download
Summary:
GB/T 8812-1988 Bending test method for rigid cellular plastics GB/T8812-1988 Standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of ChinabZxz.net
Rigid cellular plastics
Test method for bending of
rigid cellular plastics
This standard is equivalent to the international standard ISO1209-1976 "Bending test of rigid cellular plastics". 1 Subject content and scope of application
UDC678.5/7.074
: 620.174
GB 8812-88
ISO 1209--76
This standard specifies a test method for determining the bending properties of rigid cellular plastics, that is, determining the load or breaking load when the rigid cellular plastic specimen is subjected to three-point force to produce a specified deformation. Since the loading method used in this standard cannot cause pure bending deformation of the specimen, it cannot be used to calculate the bending strength and apparent bending modulus of the material. This test method is mainly used to evaluate the bending properties of foam plastics under laboratory conditions. 2 Reference standards
GB2918 Standard environment for state adjustment and testing of plastic specimens GB6342 Determination of linear dimensions of foam plastics and rubber 3 Principle
Place the specimen on a support, apply load to the specimen at a certain rate, and record the load value or breaking load value of the specimen at the specified deformation.
4 Test equipment
4.1 A compression tester or bending tester with a loading head and a support. 4.2 To avoid excessive indentation of the specimen, the top surface of the loading head and the support should be a cylindrical surface with an arc radius of 5 ± 0.2 mm, a span of 100 ± 1 mm between the two supports, and the loading head located in the center of the specimen. 5 Specimens and their preparation
5.1 Shape and size
The specimen is a rectangular parallelepiped with the following dimensions
Thickness (test height)
5.2 Specimen preparation
120±1.20 mm
25±0. 25 mm
20±0.20 mm
The cell structure of the specimen should not be deformed during specimen preparation. The specimen may be skinned on one or more sides. 5.3 Number of specimens
At least five specimens shall be tested for each type of sample. When the material to be tested is suspected to be anisotropic, two sets of specimens shall be prepared with their axes parallel and perpendicular to the direction of cell elongation, respectively.
5.4 Conditioning
GB8812-88
Test condition of the specimen is as specified in GB2918. The temperature is 23±2℃ and the relative viscosity is 45%~~55%. The size of the specimen is measured as specified in GB6342. 6 Test steps
Place the specimen in the middle of the support so that the height of the specimen is consistent with the loading direction. The pressure head contacts the specimen with the minimum pressure, and this position is recorded and used as the zero point of the specimen deformation. The loading pressure head applies load to the specimen at a rate of 10±2mm/min. Note and record the load value (in Newton) when the specimen is deformed by 20±0.2mm. If the specimen is broken before the deformation reaches 20mm, record the fracture force of the specimen and the deformation at the fracture point.
Results
Bending force (Newton);
Bending fracture force (Newton),
8Test report
The test report should include the following contents:
Load when 20mm deformation
Deformation at the fracture point (mm)
Material type and brand (including material density): Specimen surface condition:
The direction of applied load is perpendicular to the direction of cell elongation, each test result and arithmetic mean;
Test date;
Operation steps different from this standard.
Additional statement:
This standard is proposed by the Ministry of Light Industry of the People's Republic of China. This standard is under the jurisdiction of the Plastics Processing and Application Research Institute of the Ministry of Light Industry. This standard was drafted by the Shanghai Plastic Products Research Institute. 417
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Rigid cellular plastics
Test method for bending of
rigid cellular plastics
This standard is equivalent to the international standard ISO1209-1976 "Bending test of rigid cellular plastics". 1 Subject content and scope of application
UDC678.5/7.074
: 620.174
GB 8812-88
ISO 1209--76
This standard specifies a test method for determining the bending properties of rigid cellular plastics, that is, determining the load or breaking load when the rigid cellular plastic specimen is subjected to three-point force to produce a specified deformation. Since the loading method used in this standard cannot cause pure bending deformation of the specimen, it cannot be used to calculate the bending strength and apparent bending modulus of the material. This test method is mainly used to evaluate the bending properties of foam plastics under laboratory conditions. 2 Reference standards
GB2918 Standard environment for state adjustment and testing of plastic specimens GB6342 Determination of linear dimensions of foam plastics and rubber 3 Principle
Place the specimen on a support, apply load to the specimen at a certain rate, and record the load value or breaking load value of the specimen at the specified deformation.
4 Test equipment
4.1 A compression tester or bending tester with a loading head and a support. 4.2 To avoid excessive indentation of the specimen, the top surface of the loading head and the support should be a cylindrical surface with an arc radius of 5 ± 0.2 mm, a span of 100 ± 1 mm between the two supports, and the loading head located in the center of the specimen. 5 Specimens and their preparation
5.1 Shape and size
The specimen is a rectangular parallelepiped with the following dimensions
Thickness (test height)
5.2 Specimen preparation
120±1.20 mm
25±0. 25 mm
20±0.20 mm
The cell structure of the specimen should not be deformed during specimen preparation. The specimen may be skinned on one or more sides. 5.3 Number of specimens
At least five specimens shall be tested for each type of sample. When the material to be tested is suspected to be anisotropic, two sets of specimens shall be prepared with their axes parallel and perpendicular to the direction of cell elongation, respectively.
5.4 Conditioning
GB8812-88
Test condition of the specimen is as specified in GB2918. The temperature is 23±2℃ and the relative viscosity is 45%~~55%. The size of the specimen is measured as specified in GB6342. 6 Test steps
Place the specimen in the middle of the support so that the height of the specimen is consistent with the loading direction. The pressure head contacts the specimen with the minimum pressure, and this position is recorded and used as the zero point of the specimen deformation. The loading pressure head applies load to the specimen at a rate of 10±2mm/min. Note and record the load value (in Newton) when the specimen is deformed by 20±0.2mm. If the specimen is broken before the deformation reaches 20mm, record the fracture force of the specimen and the deformation at the fracture point.
Results
Bending force (Newton);
Bending fracture force (Newton),
8Test report
The test report should include the following contents:
Load when 20mm deformation
Deformation at the fracture point (mm)
Material type and brand (including material density): Specimen surface condition:
The direction of applied load is perpendicular to the direction of cell elongation, each test result and arithmetic mean;
Test date;
Operation steps different from this standard.
Additional statement:
This standard is proposed by the Ministry of Light Industry of the People's Republic of China. This standard is under the jurisdiction of the Plastics Processing and Application Research Institute of the Ministry of Light Industry. This standard was drafted by the Shanghai Plastic Products Research Institute. 417
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 8486.1-1996 CNC universal tool milling machine accuracy inspection
- GB/T 8413-1996 CZY type marine self-priming centrifugal water pump
- GB 4736-1984 Test method for air permeability of daily-use pottery
- HG/T 23014-1999 Safety regulations for high-altitude operations in factories
- GB/T 8639.6-1988 Chemical analysis method for vanadium - n-butanol extraction spectrophotometric method for determination of silicon content
- GB/T 27819-2011 Chemicals—Test method of in vitro mammalian cell transformation
- GB 30000.8-2013 Rules for classification and labelling of chemicals—Part 8:Flammable solids
- GB/T 19354-2003 Vitreous and porcelain enamels for aluminium—Determination of the adhesion of enamels on aluminium under the action of electrolytic solution(spall test)
- GB 19484.1-2004 800MHzCDMA digital cellular mobile communication system electromagnetic compatibility requirements and measurement methods Part 1: Mobile station and its auxiliary equipment
- JB/T 10159-1999 Solenoid for AC integral wet valve
- GA 173-2002 Lightning protection device for computer information system
- QB/T 1818-1993 Metal violin strings
- JB/T 6913-1993 Cleanliness of pump products
- HG/T 2722-1995 Monoisopropylamine
- JB/T 10231.17-2002 Tool product testing methods Part 17: Indexable end mills
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com