JB/T 4279.6-1994 Test equipment for enameled winding wire - Verification method - Peel tester
time:
2024-06-12 10:15:14
- JB/T 4279.6-1994
- Abolished
Standard ID:
JB/T 4279.6-1994
Standard Name:
Test equipment for enameled winding wire - Verification method - Peel tester
Chinese Name:
漆包绕组线试验仪器设备检定方法 剥离试验仪
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1994-12-09 -
Date of Implementation:
1995-06-01 -
Date of Expiration:
2008-07-01
China Standard Classification Number:
Electrical>>Electrical Production Equipment>>K91 Electrical Material Production Equipment
alternative situation:
Replaces JB 4279.6-1986; replaced by JB/T 4279.6-2008
Drafter:
Zhu BingDrafting Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryFocal point Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryProposing Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryPublishing Department:
Ministry of Machinery Industry of the People's Republic of China
Skip to download
Summary:
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and treatment of enameled round wire stripping testers. This standard applies to the verification of enameled round wire stripping testers. JB/T 4279.6-1994 Verification methods for enameled winding wire test equipment Stripping tester JB/T4279.6-1994 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China
Enameled Winding Wire Test Instrument and Equipment Calibration Method Instrument
Peeling Test
Subject Content and Scope of Application
JB/T4279.6
Replaces JR4279.686bzxZ.net
This standard specifies the calibration items and technical requirements, calibration instruments, calibration methods, calibration results and processing of enameled round wire peeling test instruments.
This standard is applicable to the calibration of enameled round wire peeling test instruments. Reference Standard
JB/T4279.1 General Rules for Calibration Methods of Enameled Winding Wire Test Instruments
Calibration Items and Technical Requirements
The distance between the two clamps of the enameled round wire residual test instrument can be adjusted to 500±5mm. The rotation speed of the sample twisting should be 60~100r/min. 3.2
The weight of the hanging rod is 5V. The load weight is 5N, 15N, 20V, 55N. The weight error range is 10%.3.3
The torsion counter counts accurately and reliably.
Instruments for verification
Steel tape measure, 2m.
Stopwatch. Graduation value 0.1%.
Electronic scale or table scale, graduation value 5g:
Verification method
General inspection
The enameled round wire peeling tester should be placed horizontally, and the slider can move smoothly on the guide rail. After clamping the sample and hanging the corresponding load, the fixture has no looseness or slippage. The scraper is sharp. The two blades are parallel. There is no gap. The torsion counter is reliable, especially the counting error. 5.2 Measure the distance between the two fixtures.
5.3 Use a stopwatch to measure and record the number of twists n of the tester within time t (greater than 1min). Calculate the twisting speed V according to the following formula: V-60n/t
Where: --- time s;
-t The number of twists within time.
Take the average of 3 calculated values.
5.4 Measure the weight of the hanging rod and the load.
Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Processing of verification results
JB/T 4279.6--94
6.1 A verification certificate shall be issued to the qualified enameled round wire peeling tester. A verification result notice shall be issued to the unqualified one. The cover of the verification certificate and verification result notice is shown in the appendix of JB/T4279.1. 6.2 The initial calibration of the enameled wire peeling tester is carried out according to all the calibration items. During the periodic calibration, only the items specified in Articles 5.1.3.2 and 5.3 of this standard need to be calibrated.
6.3 The calibration cycle of the enameled round wire peeling tester is generally set at 2 years.
Additional instructions:
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others, and the main drafter of this standard was Zhu Bing.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Enameled Winding Wire Test Instrument and Equipment Calibration Method Instrument
Peeling Test
Subject Content and Scope of Application
JB/T4279.6
Replaces JR4279.686bzxZ.net
This standard specifies the calibration items and technical requirements, calibration instruments, calibration methods, calibration results and processing of enameled round wire peeling test instruments.
This standard is applicable to the calibration of enameled round wire peeling test instruments. Reference Standard
JB/T4279.1 General Rules for Calibration Methods of Enameled Winding Wire Test Instruments
Calibration Items and Technical Requirements
The distance between the two clamps of the enameled round wire residual test instrument can be adjusted to 500±5mm. The rotation speed of the sample twisting should be 60~100r/min. 3.2
The weight of the hanging rod is 5V. The load weight is 5N, 15N, 20V, 55N. The weight error range is 10%.3.3
The torsion counter counts accurately and reliably.
Instruments for verification
Steel tape measure, 2m.
Stopwatch. Graduation value 0.1%.
Electronic scale or table scale, graduation value 5g:
Verification method
General inspection
The enameled round wire peeling tester should be placed horizontally, and the slider can move smoothly on the guide rail. After clamping the sample and hanging the corresponding load, the fixture has no looseness or slippage. The scraper is sharp. The two blades are parallel. There is no gap. The torsion counter is reliable, especially the counting error. 5.2 Measure the distance between the two fixtures.
5.3 Use a stopwatch to measure and record the number of twists n of the tester within time t (greater than 1min). Calculate the twisting speed V according to the following formula: V-60n/t
Where: --- time s;
-t The number of twists within time.
Take the average of 3 calculated values.
5.4 Measure the weight of the hanging rod and the load.
Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Processing of verification results
JB/T 4279.6--94
6.1 A verification certificate shall be issued to the qualified enameled round wire peeling tester. A verification result notice shall be issued to the unqualified one. The cover of the verification certificate and verification result notice is shown in the appendix of JB/T4279.1. 6.2 The initial calibration of the enameled wire peeling tester is carried out according to all the calibration items. During the periodic calibration, only the items specified in Articles 5.1.3.2 and 5.3 of this standard need to be calibrated.
6.3 The calibration cycle of the enameled round wire peeling tester is generally set at 2 years.
Additional instructions:
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others, and the main drafter of this standard was Zhu Bing.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 39315.5-2020 General resource of military and civilian—Data model—Part 5:Person
- GB 17936-1999 Bayonet lamp holder
- GB/T 11441-1989 Transformer and inductor core sheets for communication and electronic equipment
- GB/T 5341-1985 Indexable face and side milling cutters
- JB/T 8941.2-1999 Roots blowers for general use Part 2: Performance test methods
- HG/T 20670-2000 Chemical and petrochemical pipe rack and pipe pier design regulations (with clause explanation)
- GB 594-1983 Marine external thread forged steel stop valve
- JG/T 3057-1999 Upset straight threaded steel bar joint JG/T3057-1999
- JB/T 3411.105-1999 7:24 Dimensions of long Morse taper intermediate sleeves for taper/forced transmission
- GB/T 29186.4-2021 Brand value factor evaluation Part 4: Innovation factor
- HG/T 2480-1993 Metal-clad gaskets for pipe flanges
- GB/T 15072.13-1994 Chemical analysis methods for precious metals and their alloys - Determination of cerium content in silver alloys
- GB/T 17143.3-1997 Information technology Open Systems Interconnection System management Part 3: Attributes representing relationships
- GB/T 2461-1996 Determination of moisture content in pyrite and pyrite concentrates - Gravimetric method
- GB/T 14895-1994 Terminology of metal cutting tools - Gear cutting tools
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com