HG 3229-1989 Flat plate vulcanizing press test method
time:
2024-08-13 18:20:14
- HG 3229-1989
- in force
Standard ID:
HG 3229-1989
Standard Name:
Flat plate vulcanizing press test method
Chinese Name:
平板硫化机检测方法
Standard category:
Chemical industry standards (HG)
alternative situation:
ZB G95011-88
Skip to download
Summary:
HG 3229-1989 Flatbed vulcanizing press test method HG3229-1989 standard download decompression password: www.bzxz.net
Some standard content:
Professional Standard of the People's Republic of China
1G32298
Daylight press-Testing and measuring methodsPublished on 1989-02-28
Implemented on 1989-05-01
Published by the Ministry of Chemical Industry of the People's Republic of ChinaProfessional Standard of the People's Republic of China
Daylight press -Testing and
measuring methods
Subject Content and Scope of Application
This standard specifies the testing methods for the main items of the plate vulcanizer. This standard is applicable to the testing of hydraulic plate vulcanizers. This standard should be used in conjunction with the product standard GB10480 "Plate Vulcanizer". Main accuracy and performance tests (see Table 1) 2
Test items
Surface
Roughness
Nominal mold
Test method
Test at any
distance from the edges of the hot plate.
(1) Measure with a stylus surface roughness measuring instrument,
(2) Compare and judge with a surface roughness comparison sample.
Both methods have equal validity
Place a mold or a rubber sheet of appropriate thickness between each layer of hot plate to prevent direct contact with the working surface of the hot plate.
Pressure at the maximum working pressure for 5 minutes and record the pressure gauge reading. Use the following formula to calculate the nominal clamping force: P=10-4.P,·Fn
Wherein: P is the nominal clamping force, MN; P—the pressure gauge reading, MPa; F—the area of the hydraulic pressure acting on the plunger, cm2; Number of hydraulic cylinders: The thickness of the hot plate approved by the Ministry of Chemical Industry of the People's Republic of China on February 28, 1989: One measuring point
ZBG95011-89bzxz.net
Testing tools
Stylus-type surface
Roughness measurement
Surface roughness
Comparison sample
Pressure gauge
1989-05-01Implementation
Testing items
Opening and closing of hot plate
ZBG95011--89
Continued Table 1
Testing methods
When the hot plate is running to a stable state, put it in a completely closed position. Start to press the "open" button and use a stopwatch to record the time. When the hot plate drops to the maximum open position and stops moving, stop the timer and record the time. And use a steel ruler to measure the distance of the opening.
When the hot plate is in the maximum open position, start pressing the "Close" button and use a stopwatch to time. When the hot plate is completely closed and stops moving, stop the timer to record the time and measure the closing distance.
Repeat the measurement three times in a row, calculate separately, and take the smaller value as the opening and closing speed of the hot plate.
Hot-steam heated or electrically heated flat vulcanizer: High working temperature Use saturated steam with a force of 1MPa or connect the hot plate working
power supply to heat the hot plate to a stable state. According to the measurement range L shown in the figure, use a point thermometer of the corresponding range to measure near the center line.
L<1000mm, measure one point,
1000mmL<3000mm, measure point
3000mm
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
1G32298
Daylight press-Testing and measuring methodsPublished on 1989-02-28
Implemented on 1989-05-01
Published by the Ministry of Chemical Industry of the People's Republic of ChinaProfessional Standard of the People's Republic of China
Daylight press -Testing and
measuring methods
Subject Content and Scope of Application
This standard specifies the testing methods for the main items of the plate vulcanizer. This standard is applicable to the testing of hydraulic plate vulcanizers. This standard should be used in conjunction with the product standard GB10480 "Plate Vulcanizer". Main accuracy and performance tests (see Table 1) 2
Test items
Surface
Roughness
Nominal mold
Test method
Test at any
distance from the edges of the hot plate.
(1) Measure with a stylus surface roughness measuring instrument,
(2) Compare and judge with a surface roughness comparison sample.
Both methods have equal validity
Place a mold or a rubber sheet of appropriate thickness between each layer of hot plate to prevent direct contact with the working surface of the hot plate.
Pressure at the maximum working pressure for 5 minutes and record the pressure gauge reading. Use the following formula to calculate the nominal clamping force: P=10-4.P,·Fn
Wherein: P is the nominal clamping force, MN; P—the pressure gauge reading, MPa; F—the area of the hydraulic pressure acting on the plunger, cm2; Number of hydraulic cylinders: The thickness of the hot plate approved by the Ministry of Chemical Industry of the People's Republic of China on February 28, 1989: One measuring point
ZBG95011-89bzxz.net
Testing tools
Stylus-type surface
Roughness measurement
Surface roughness
Comparison sample
Pressure gauge
1989-05-01Implementation
Testing items
Opening and closing of hot plate
ZBG95011--89
Continued Table 1
Testing methods
When the hot plate is running to a stable state, put it in a completely closed position. Start to press the "open" button and use a stopwatch to record the time. When the hot plate drops to the maximum open position and stops moving, stop the timer and record the time. And use a steel ruler to measure the distance of the opening.
When the hot plate is in the maximum open position, start pressing the "Close" button and use a stopwatch to time. When the hot plate is completely closed and stops moving, stop the timer to record the time and measure the closing distance.
Repeat the measurement three times in a row, calculate separately, and take the smaller value as the opening and closing speed of the hot plate.
Hot-steam heated or electrically heated flat vulcanizer: High working temperature Use saturated steam with a force of 1MPa or connect the hot plate working
power supply to heat the hot plate to a stable state. According to the measurement range L shown in the figure, use a point thermometer of the corresponding range to measure near the center line.
L<1000mm, measure one point,
1000mmL<3000mm, measure point
3000mm
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 1512-1992 Limit deviations of un-toleranced dimensions of sewing machine parts
- HG/T 2647-1994 Technical requirements for length measuring machines for ordinary V-belts and narrow V-belts
- GB/T 5359.4-1994 Names of parts for motorcycles and mopeds
- GB/T 19022.2-2000 Quality assurance for measuring equipment-Part 2: Guidelines for control of measurement processes
- JB/T 2426-1992 Technical parameters and requirements of three-phase transformers for power plants and substations
- JJG 658-1990 Verification Regulation of Instruments for Measuring the Moisture Content of Grain with Baking Method
- SJ 20682-1998 General specification for Lx band solid-state pulse power modules
- JB/T 8005.2-1999 Machine tool fixture parts and components screw-in threaded bushings
- JB/T 5000.13-1998 General technical conditions for heavy machinery packaging
- JGJ 80-1991 Technical Specification for Safety of Height Operations in Construction
- QB/T 1693-1993 Terminology of pulp and paper machinery and equipment