GB/T 11473-1989 Method for compiling reciprocating pump models
time:
2024-08-06 11:39:16
- GB/T 11473-1989
- Abolished
Standard ID:
GB/T 11473-1989
Standard Name:
Method for compiling reciprocating pump models
Chinese Name:
往复泵 型号编制方法
Standard category:
National Standard (GB)
-
Date of Release:
1989-03-29 -
Date of Implementation:
1990-01-01 -
Date of Expiration:
2005-10-14
Standard ICS number:
Fluid Systems and General Parts >> 23.080 PumpsChina Standard Classification Number:
Electronic Components and Information Technology>>Information Processing Technology>>L71 Coding, Character Set, Character Recognition
alternative situation:
JB 4134-1985
Review date:
2004-10-14Drafting Organization:
Hefei General Machinery FactoryFocal point Organization:
National Pump Standardization Technical CommitteePublishing Department:
China Machinery Industry FederationCompetent Authority:
China Machinery Industry Federation
Skip to download
Summary:
GB/T 11473-1989 Method for compiling the model of reciprocating pumps GB/T11473-1989 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
The model desigeation of reciprocatng pump1Subject content and scope of application
This standard specifies the model desigeation of reciprocatng pump. This standard is applicable to mechanical, gas (steam) driven, hydraulic and manual reciprocating pumps. 2 Model Indication Method
The model of a reciprocating pump consists of capital Chinese Pinyin letters and Arabic numerals, and the indication method is as follows: 0 0 0-0/00.0
Variable model: indicated by numbers 1~9
Special performance: indicated by letters
Rated discharge pressure: indicated by numbers, MPaRated flow: indicated by numbers
GB 11473—89
Structural type: vertical type is L, diaphragm type is M, and other types are not indicated. First characteristic: indicated by letters
Number of couplings (cylinders): indicated by numbers, single coupling (cylinder) is not indicated. Note: ①The first characteristic of the pump refers to the most representative feature of the pump selected from the five categories of pump driving mode, auxiliary medium, structural characteristics, functions and main supporting facilities (see Table 1).
②The content in the dotted box is the reference section (see Chapter 4). Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 29, 1989 and implemented on January 1, 1990
Pneumatic (steam) pump
Electric pump
Hydraulic pump
Hydraulic pump
Metering pump
Hand pump
General motor pump
Impurity pump
First feature
Oil isolation
Water isolation
Water flushing
3 Rated flow and rated discharge pressure
3.1 The units of rated flow are stipulated as follows:
a. Metering pump and pressure test pump: L/h,
b. Manual pump: mL/time:
other pumps: m*/h;
GB1147389
recorded
gas (steam) water
gas) oil
gas (steam)
3.2 The rated flow of the adjustable volume pump marks the maximum rated flow value of the pump. 1. Characteristics
General motor pumps
Chemical pumps and
Other pumps
First characteristics
Catalysts
FluorinewwW.bzxz.Net
Carbamic acid
Silicic acid baking liquid
Deionized
Copper acetate ammonia liquid
Steam condensate
3.3 The rated flow of multi-cylinder metering pumps is expressed by multiplying the number of cylinders by the rated flow of a single cylinder. The rated flow of other multi-cylinder pumps is expressed by the sum of the rated flows of each cylinder.
3.4 For multi-unit metering pumps, the rated flow and rated discharge pressure of each unit cylinder should be listed separately, and the parameters of each unit should be separated by a withdrawal sign. 4. The last two boxes in the model representation method are reference sections, which can be marked or not. Special performance is represented by the code specified in Table 2. If multiple special properties need to be marked in parallel, they can be marked in the order of letters in Table 2. Special properties
Throttle flow
Guard jacket
Marking example
2QY-22/3.5
GB 11473—89
Table 2 Special properties of pumps
Letter code
Double-cylinder horizontal pneumatic reciprocating oil pump, rated flow 22 m/h, rated discharge pressure 3.5 MPa. b.
DY-63/5
Single-cylinder horizontal electric test pressure pump, rated flow 63L/h, rated discharge pressure 5MPa. c.SYL-22/5
Single-cylinder vertical manual test pressure pump, rated flow 22mL/h, rated discharge pressure 5MPa. d.JM-100/2.5
single cylinder horizontal diaphragm electric metering pump, rated flow 100L/h, rated discharge pressure 2.5MPa3J-2×2509/1,40/0.6-T1
two-unit horizontal electric metering pump, the first and second unit flow rates are 2500L/h respectively, and the rated discharge pressure is 1MPa. : The third unit rated flow rate is 401./h, the rated discharge pressure is 0.6MPa, the flow rate can be adjusted, the first modification. f.
2QM-40/0. 7
double cylinder horizontal pneumatic diaphragm pump, rated flow 40m*/h, rated discharge pressure 0.7MPa. SDM-100/0. 3
single cylinder manual diaphragm slurry, rated flow 100mL/time, rated discharge pressure 0.3MPa. 3JA-60/1, 5-B
Three-cylinder horizontal electric reciprocating methyl ammonium pump, rated flow 60m2/h, rated discharge pressure 1.5MPa, explosion-proof. 1.3S-40/10
Three-cylinder horizontal electric reciprocating water pump, rated flow 40 gong*/h, rated discharge pressure 10 MPa. 3KM-30/2-T2
Three-cylinder horizontal electric diaphragm impurity pump, rated flow 30m*/h, rated discharge pressure 2MPa, adjustable flow, second variant. k.3KC-180/2.5
Three-cylinder horizontal water flushing electric impurity pump, rated flow 180m/h, rated discharge pressure 2.5MPa Additional remarks:
This standard is drafted by Hefei General Machinery Research Institute. The main drafters of this standard are Xiang Qinan and Xu Jianqiang. From the date of implementation of this standard, the former Ministry of Machinery of the People's Republic of China issued the Ministry of Standards JB4134-85 "Method for Compiling Reciprocating Pump Models" will be invalid.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
The model desigeation of reciprocatng pump1Subject content and scope of application
This standard specifies the model desigeation of reciprocatng pump. This standard is applicable to mechanical, gas (steam) driven, hydraulic and manual reciprocating pumps. 2 Model Indication Method
The model of a reciprocating pump consists of capital Chinese Pinyin letters and Arabic numerals, and the indication method is as follows: 0 0 0-0/00.0
Variable model: indicated by numbers 1~9
Special performance: indicated by letters
Rated discharge pressure: indicated by numbers, MPaRated flow: indicated by numbers
GB 11473—89
Structural type: vertical type is L, diaphragm type is M, and other types are not indicated. First characteristic: indicated by letters
Number of couplings (cylinders): indicated by numbers, single coupling (cylinder) is not indicated. Note: ①The first characteristic of the pump refers to the most representative feature of the pump selected from the five categories of pump driving mode, auxiliary medium, structural characteristics, functions and main supporting facilities (see Table 1).
②The content in the dotted box is the reference section (see Chapter 4). Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 29, 1989 and implemented on January 1, 1990
Pneumatic (steam) pump
Electric pump
Hydraulic pump
Hydraulic pump
Metering pump
Hand pump
General motor pump
Impurity pump
First feature
Oil isolation
Water isolation
Water flushing
3 Rated flow and rated discharge pressure
3.1 The units of rated flow are stipulated as follows:
a. Metering pump and pressure test pump: L/h,
b. Manual pump: mL/time:
other pumps: m*/h;
GB1147389
recorded
gas (steam) water
gas) oil
gas (steam)
3.2 The rated flow of the adjustable volume pump marks the maximum rated flow value of the pump. 1. Characteristics
General motor pumps
Chemical pumps and
Other pumps
First characteristics
Catalysts
FluorinewwW.bzxz.Net
Carbamic acid
Silicic acid baking liquid
Deionized
Copper acetate ammonia liquid
Steam condensate
3.3 The rated flow of multi-cylinder metering pumps is expressed by multiplying the number of cylinders by the rated flow of a single cylinder. The rated flow of other multi-cylinder pumps is expressed by the sum of the rated flows of each cylinder.
3.4 For multi-unit metering pumps, the rated flow and rated discharge pressure of each unit cylinder should be listed separately, and the parameters of each unit should be separated by a withdrawal sign. 4. The last two boxes in the model representation method are reference sections, which can be marked or not. Special performance is represented by the code specified in Table 2. If multiple special properties need to be marked in parallel, they can be marked in the order of letters in Table 2. Special properties
Throttle flow
Guard jacket
Marking example
2QY-22/3.5
GB 11473—89
Table 2 Special properties of pumps
Letter code
Double-cylinder horizontal pneumatic reciprocating oil pump, rated flow 22 m/h, rated discharge pressure 3.5 MPa. b.
DY-63/5
Single-cylinder horizontal electric test pressure pump, rated flow 63L/h, rated discharge pressure 5MPa. c.SYL-22/5
Single-cylinder vertical manual test pressure pump, rated flow 22mL/h, rated discharge pressure 5MPa. d.JM-100/2.5
single cylinder horizontal diaphragm electric metering pump, rated flow 100L/h, rated discharge pressure 2.5MPa3J-2×2509/1,40/0.6-T1
two-unit horizontal electric metering pump, the first and second unit flow rates are 2500L/h respectively, and the rated discharge pressure is 1MPa. : The third unit rated flow rate is 401./h, the rated discharge pressure is 0.6MPa, the flow rate can be adjusted, the first modification. f.
2QM-40/0. 7
double cylinder horizontal pneumatic diaphragm pump, rated flow 40m*/h, rated discharge pressure 0.7MPa. SDM-100/0. 3
single cylinder manual diaphragm slurry, rated flow 100mL/time, rated discharge pressure 0.3MPa. 3JA-60/1, 5-B
Three-cylinder horizontal electric reciprocating methyl ammonium pump, rated flow 60m2/h, rated discharge pressure 1.5MPa, explosion-proof. 1.3S-40/10
Three-cylinder horizontal electric reciprocating water pump, rated flow 40 gong*/h, rated discharge pressure 10 MPa. 3KM-30/2-T2
Three-cylinder horizontal electric diaphragm impurity pump, rated flow 30m*/h, rated discharge pressure 2MPa, adjustable flow, second variant. k.3KC-180/2.5
Three-cylinder horizontal water flushing electric impurity pump, rated flow 180m/h, rated discharge pressure 2.5MPa Additional remarks:
This standard is drafted by Hefei General Machinery Research Institute. The main drafters of this standard are Xiang Qinan and Xu Jianqiang. From the date of implementation of this standard, the former Ministry of Machinery of the People's Republic of China issued the Ministry of Standards JB4134-85 "Method for Compiling Reciprocating Pump Models" will be invalid.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 5210-1991 Upper seal seat
- GB/T 9120.2-2000 Concave and convex face welded ring plate loose sleeve steel pipe flange
- LB/T 024-2013 Requirements on services quality of tourism blocks and streets
- JB/T 10019-1999 Gear pitch measuring instrument
- JB/T 51192-1999 Agricultural screw oil press product quality classification
- SB/T 10991-2013 Beauty salon services standard
- GB/T 8106-1987 Directional control valve test method
- QB/T 2034.1-2005 Sewing machine terminology Part 1: Basic terminology
- SC 1064-2003 Bigmouth Beef Redfin
- GB/T 39315.5-2020 General resource of military and civilian—Data model—Part 5:Person
- JB/T 9165.1-1998 Process Document Integrity
- QB/T 2690-2005 Carbon paper
- JB/T 6413-1992 Type and basic parameters of inlet air heating unit
- MT 355-2005 Technical requirements for mine fall arresters
- GB/T 4699.1-1984 Chemical analysis methods for silicon-chromium alloys - Gravimetric method for determination of silicon content
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com