CB/T 3897-1999 Marine 16~125A plugs, sockets and connectors
time:
2024-10-24 14:12:12
- CB/T 3897-1999
- in force
Standard ID:
CB/T 3897-1999
Standard Name:
Marine 16~125A plugs, sockets and connectors
Chinese Name:
船用16~125A插头插座和连接器
Standard category:
Ship Industry Standard (CB)
-
Date of Release:
1990-04-20 -
Date of Implementation:
1990-12-01
Standard ICS number:
Shipbuilding and offshore structures>>Shipbuilding and offshore structures in general>>47.020.60 Marine electrical equipmentChina Standard Classification Number:
Ships>>Marine electrical, observation and navigation equipment>>U62 marine electronic control device and measuring equipment
alternative situation:
Original standard number GB 12321-90

Skip to download
Summary:
CB/T 3897-1999 Marine 16~125A plugs, sockets and connectors CB/T3897-1999 Standard download decompression password: www.bzxz.net

Some standard content:
UDC621.316.541:629.12
National Standard of the People's Republic of China
GB1232190
CBh 3897-1999
Marine 16~125A plugs, socket-outletsand couplers
1990-04-20 Issued
State Bureau of Technical Supervision
1990-12-01 Implementation
Subject content and scope of application……
2 Reference standards
3 Terms…
4 Product classification…
5 Technical requirements
6 Test methods
7·Inspection rules·
8 Marking, packaging, transportation and storage.
Appendix A Grounding contact position diagram (supplement) Table of contents
Appendix B Schematic diagram of plugs, sockets and connectors (reference) Times
........
National Standard of the People's Republic of China
Marine 16~125A plugs, socket-outlets and couplers
1 Subject content and scope of application
GB12321-90
This standard specifies the classification, technical requirements, test methods and inspection rules for marine 16~125A plugs, socket-outlets and couplers. This standard applies to plugs, sockets and connectors with an AC voltage of 50Hz or 60Hz, a rated voltage not exceeding 440V or a DC rated voltage not exceeding 220V, and a rated current of 16 to 125A, used in general ships, refrigerated containers and docks. However, it is not applicable to places with explosion hazards.
2 Reference standards
GB2099
Packaging storage and transportation pictorial signs
Technical conditions for single-phase and three-phase plugs and sockets
GB2423.10
GB2423.16
GB2423.17
Basic environmental test regulations for electrical and electronic products are test A: low temperature test method
Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test procedures for electronic products GB4942.2
Protection level of low-voltage electrical enclosures
3 Terms
3.1 Interlocking device
Test B: High temperature test method
Test Db: Alternating damp heat test method
Test Fc: Vibration (sinusoidal) test method Test J: Mildew test method
Test Ka: Salt mildew test method
It refers to a mechanical structure that prevents the plug pin from being energized before the plug and socket or connector are plugged in, and can also prevent the plug pin from being pulled out when energized.
3.2 Retention device
It refers to a mechanical structure that keeps the plug or connector in the normal working position when it is plugged in to prevent accidental disengagement. 4 Product classification
4.1 See Table 1 for basic parameters.
Approved by the State Administration of Technical Supervision on April 20, 1990, and implemented on December 12, 1990
Rated current
3P+N++
312321-90
50 or 60
50 or 60
50 or 60
Rated voltage
110 or 220
250 or 440
Grounding contact
Clock position
Note: ① The position of the grounding contact is determined by comparing the front of the socket with the clock face, setting the key slot position at 6 o'clock (6h), and then according to the clock position of the grounding socket, see Appendix A (supplement). 250V or 440V is only for refrigerated containers. 4.2
The arrangement diagram of the socket and the pin of the plug is shown in Figures 1 and 2. Current level
Socket 5
Grounding hole Φ7
Socket 6
Grounding hole 8
Socket electric 8
Grounding hole Φ10
Socket 10
Grounding hole 12
Auxiliary publication
Auxiliary hole
GB12321—90
Socket $5
Grounding no 7
Socket 46
Grounding hole 8
Socket 8
|Grounding hole 10
Socket $10
Grounding hole $12
Auxiliary hole
Auxiliary hole
Schematic diagram of socket socket arrangement
Socket 5
Grounding hole 7
Socket 46
Grounding hole Φ8
Socket 8
Grounding hole 10
Socket 10
Grounding hole 12
Current level
Pin $5
Grounding pin $7
Broadcast pin 46
Ground pin 8
Pin 18
Ground pin center 10
Pin 10
Ground pin center 12
Assistance pin
GB1232190
Pin $5
Ground pin 47
Pin: 6
Ground pin center 8
Pin 48
Ground pin 410
Pin 10
Ground pin 412|| tt||End auxiliary pin
Figure 2 Schematic diagram of the pin arrangement of the plug
Pin $5
Grounding pin
Pin 46
Grounding pin 48
Pin 48
Grounding pin 410
3P+N+→
Pin 410
Anding pin 12
GB12321—90
4. The structure and dimensions of 316A and 32A sockets and connector sockets are shown in Figure 3 and Table 2. h
R3.5±0.2
2P+↓
3P+↓
3P+N++
3P+N++
3P+↓
3P+↓
3P+N+→
Figures 316A and 32A sockets and connector sockets
Chamfer of socket sleeve
Phase and neutral line plug plate
Earthing socket
3P+N+1
GB1232190
Continued Table 2
Note: 1) Within the distance specified by ts, d and L should be within the limit. If ts is exceeded, d and L can be greater than the specified value. 2) The dimensions of the socket d and d do not have to be circular, which is related to the pin. 3) For the socket with 3P+N++10 poles, the value of dimension h for the neutral line socket is 16.0mm. 4.4 The construction and dimensions of 16A and 32A plugs and connector plugs are shown in Figure 4 and Table 3. End of the plug
Phase and neutral line plugs
Insulating bushing
Figure 416A and 32A plugs and connector plugs
Earthing plug
3P+N++
2P+↓
3P+↓
3P+N+↓
3P+N+G
3P+N++
3P+↓
3P+N++
Note: 1) Applicable to plugs with metal shells. d2
GB12321-90
2) Applicable to plugs with non-metallic shells. Limit
Limit deviation
Basic sizewwW.bzxz.Net
Basic size
GB12321-90
4.The structure and dimensions of the sockets and connector sockets of 563A and 125A without auxiliary jacks are shown in Figure 5 and Table 4. 15min
R05min
Figure 563A and 125A sockets and connector sockets without auxiliary holes Table 4
3P+N++
3P+N++
3P+N++
Chamfer of socket
Phase and neutral sockets
Earthing socket
+1 03)
With electrical interlock
With mechanical interlock
21 or 40
Note: 1) Within a distance of 15mm, d and L should be within the limit value. If it exceeds 15mm, d and L can be greater than the specified value. 2) The dimensions of the socket d and dg do not have to be round, which is related to the pin. 3) For sockets with 3P+N+Pole, the depth h of the neutral contact should be less than the depth of the phase contact and greater than the depth of the grounding contact. 8
No interlock
21 or 40
GB12321-90
4.663A and 125A sockets and connector sockets with auxiliary jacks have a structure and dimensions shown in Figure 6 and Table 4. h,
63A and 125A sockets and connector sockets with auxiliary jacks Figure 6
Chamfer of socket sleeve
Phase and neutral socket
Auxiliary socket sleeve
Grounding socket
4.763A and 125A plugs and connector plugs without auxiliary pins have a structure and dimensions shown in Figure 7 and Table 5. hg
End of pin
Phase and neutral pins
Earth pin
Figure 763A and 125A Plugs and connectors without auxiliary pins Plug insulation food
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of China
GB1232190
CBh 3897-1999
Marine 16~125A plugs, socket-outletsand couplers
1990-04-20 Issued
State Bureau of Technical Supervision
1990-12-01 Implementation
Subject content and scope of application……
2 Reference standards
3 Terms…
4 Product classification…
5 Technical requirements
6 Test methods
7·Inspection rules·
8 Marking, packaging, transportation and storage.
Appendix A Grounding contact position diagram (supplement) Table of contents
Appendix B Schematic diagram of plugs, sockets and connectors (reference) Times
........
National Standard of the People's Republic of China
Marine 16~125A plugs, socket-outlets and couplers
1 Subject content and scope of application
GB12321-90
This standard specifies the classification, technical requirements, test methods and inspection rules for marine 16~125A plugs, socket-outlets and couplers. This standard applies to plugs, sockets and connectors with an AC voltage of 50Hz or 60Hz, a rated voltage not exceeding 440V or a DC rated voltage not exceeding 220V, and a rated current of 16 to 125A, used in general ships, refrigerated containers and docks. However, it is not applicable to places with explosion hazards.
2 Reference standards
GB2099
Packaging storage and transportation pictorial signs
Technical conditions for single-phase and three-phase plugs and sockets
GB2423.10
GB2423.16
GB2423.17
Basic environmental test regulations for electrical and electronic products are test A: low temperature test method
Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test procedures for electronic products GB4942.2
Protection level of low-voltage electrical enclosures
3 Terms
3.1 Interlocking device
Test B: High temperature test method
Test Db: Alternating damp heat test method
Test Fc: Vibration (sinusoidal) test method Test J: Mildew test method
Test Ka: Salt mildew test method
It refers to a mechanical structure that prevents the plug pin from being energized before the plug and socket or connector are plugged in, and can also prevent the plug pin from being pulled out when energized.
3.2 Retention device
It refers to a mechanical structure that keeps the plug or connector in the normal working position when it is plugged in to prevent accidental disengagement. 4 Product classification
4.1 See Table 1 for basic parameters.
Approved by the State Administration of Technical Supervision on April 20, 1990, and implemented on December 12, 1990
Rated current
3P+N++
312321-90
50 or 60
50 or 60
50 or 60
Rated voltage
110 or 220
250 or 440
Grounding contact
Clock position
Note: ① The position of the grounding contact is determined by comparing the front of the socket with the clock face, setting the key slot position at 6 o'clock (6h), and then according to the clock position of the grounding socket, see Appendix A (supplement). 250V or 440V is only for refrigerated containers. 4.2
The arrangement diagram of the socket and the pin of the plug is shown in Figures 1 and 2. Current level
Socket 5
Grounding hole Φ7
Socket 6
Grounding hole 8
Socket electric 8
Grounding hole Φ10
Socket 10
Grounding hole 12
Auxiliary publication
Auxiliary hole
GB12321—90
Socket $5
Grounding no 7
Socket 46
Grounding hole 8
Socket 8
|Grounding hole 10
Socket $10
Grounding hole $12
Auxiliary hole
Auxiliary hole
Schematic diagram of socket socket arrangement
Socket 5
Grounding hole 7
Socket 46
Grounding hole Φ8
Socket 8
Grounding hole 10
Socket 10
Grounding hole 12
Current level
Pin $5
Grounding pin $7
Broadcast pin 46
Ground pin 8
Pin 18
Ground pin center 10
Pin 10
Ground pin center 12
Assistance pin
GB1232190
Pin $5
Ground pin 47
Pin: 6
Ground pin center 8
Pin 48
Ground pin 410
Pin 10
Ground pin 412|| tt||End auxiliary pin
Figure 2 Schematic diagram of the pin arrangement of the plug
Pin $5
Grounding pin
Pin 46
Grounding pin 48
Pin 48
Grounding pin 410
3P+N+→
Pin 410
Anding pin 12
GB12321—90
4. The structure and dimensions of 316A and 32A sockets and connector sockets are shown in Figure 3 and Table 2. h
R3.5±0.2
2P+↓
3P+↓
3P+N++
3P+N++
3P+↓
3P+↓
3P+N+→
Figures 316A and 32A sockets and connector sockets
Chamfer of socket sleeve
Phase and neutral line plug plate
Earthing socket
3P+N+1
GB1232190
Continued Table 2
Note: 1) Within the distance specified by ts, d and L should be within the limit. If ts is exceeded, d and L can be greater than the specified value. 2) The dimensions of the socket d and d do not have to be circular, which is related to the pin. 3) For the socket with 3P+N++10 poles, the value of dimension h for the neutral line socket is 16.0mm. 4.4 The construction and dimensions of 16A and 32A plugs and connector plugs are shown in Figure 4 and Table 3. End of the plug
Phase and neutral line plugs
Insulating bushing
Figure 416A and 32A plugs and connector plugs
Earthing plug
3P+N++
2P+↓
3P+↓
3P+N+↓
3P+N+G
3P+N++
3P+↓
3P+N++
Note: 1) Applicable to plugs with metal shells. d2
GB12321-90
2) Applicable to plugs with non-metallic shells. Limit
Limit deviation
Basic sizewwW.bzxz.Net
Basic size
GB12321-90
4.The structure and dimensions of the sockets and connector sockets of 563A and 125A without auxiliary jacks are shown in Figure 5 and Table 4. 15min
R05min
Figure 563A and 125A sockets and connector sockets without auxiliary holes Table 4
3P+N++
3P+N++
3P+N++
Chamfer of socket
Phase and neutral sockets
Earthing socket
+1 03)
With electrical interlock
With mechanical interlock
21 or 40
Note: 1) Within a distance of 15mm, d and L should be within the limit value. If it exceeds 15mm, d and L can be greater than the specified value. 2) The dimensions of the socket d and dg do not have to be round, which is related to the pin. 3) For sockets with 3P+N+Pole, the depth h of the neutral contact should be less than the depth of the phase contact and greater than the depth of the grounding contact. 8
No interlock
21 or 40
GB12321-90
4.663A and 125A sockets and connector sockets with auxiliary jacks have a structure and dimensions shown in Figure 6 and Table 4. h,
63A and 125A sockets and connector sockets with auxiliary jacks Figure 6
Chamfer of socket sleeve
Phase and neutral socket
Auxiliary socket sleeve
Grounding socket
4.763A and 125A plugs and connector plugs without auxiliary pins have a structure and dimensions shown in Figure 7 and Table 5. hg
End of pin
Phase and neutral pins
Earth pin
Figure 763A and 125A Plugs and connectors without auxiliary pins Plug insulation food
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 5009.3-2003 Determination of moisture in food
- JB/T 6939.2-1993 Test method for controllers for small wind turbines
- SY 6457-2000 Safety regulations for sour natural gas pipelines
- GB 3776.1-1983 Determination of moisture content in pesticide emulsifiers
- NY/T 5117-2002 Technical regulations for the production of pollution-free food rice
- JB/T 6724-1993 Metallographic inspection of ductile iron piston rings for internal combustion engines
- JB/T 50178-1999 Energy consumption classification of vacuum impregnation process for power capacitors
- GB/T 39318-2020 General resource of military and civilian—Requirement for identification number mapping
- SY 6501-2000 Safety regulations for radioactive and explosive materials in shallow water petroleum operations
- GB/T 39570-2020 Requirements for image display of electronic commerce transaction product
- SJ/T 11039-1996 Test method for annealing point and strain point of electronic glass
- JB/T 6624-1993 Test method for Shore hardness of flexible graphite sheet
- GB/T 11798.3-2001 Technical requirements for the verification of motor vehicle safety testing equipment Part 3: Technical requirements for the verification of gasoline vehicle exhaust gas analyzers
- GB/T 4244-2004 Straight shank machine reamers with angled edges
- JJF 1153-2006 Calibration Specification for Shock Accelerometers(Absolute Method)
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]