GB 18096-2000 Test method for safety of combustible gas in electric detonators for use in coal mines
time:
2024-08-06 00:31:10
- GB 18096-2000
- in force
Standard ID:
GB 18096-2000
Standard Name:
Test method for safety of combustible gas in electric detonators for use in coal mines
Chinese Name:
煤矿许用电雷管可燃气安全度试验方法
Standard category:
National Standard (GB)
-
Date of Release:
2000-05-09 -
Date of Implementation:
2000-07-01
Standard ICS number:
Chemical Technology>>Chemical Products>>71.100.30 Explosives and FireworksChina Standard Classification Number:
Chemicals>>Other Chemical Products>>G89 Explosive Products
publishing house:
China Standards PressISBN:
155066.1-16785Publication date:
2004-04-16
Release date:
2000-05-09Review date:
2004-10-14Drafting Organization:
Coal Industry Huaibei Explosive Equipment Product Quality Supervision and Inspection CenterFocal point Organization:
Commission of Science, Technology and Industry for National DefensePublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaCompetent Authority:
Commission of Science, Technology and Industry for National Defense

Skip to download
Summary:
This standard specifies the materials, instruments, devices, test conditions, test steps and test result statements for the test of the combustible gas safety of electric detonators permitted in coal mines. This standard is applicable to the test of the combustible gas safety of electric detonators permitted in coal mines. GB 18096-2000 Test method for the combustible gas safety of electric detonators permitted in coal mines GB18096-2000 Standard download decompression password: www.bzxz.net

Some standard content:
GB 18096--2000
This standard is formulated on the basis of MT62-1997 "Test Method and Judgment Rules for Safety of Underground Combustible Gases for Permissible Electric Detonators in Coal Mines" and in accordance with the requirements of GB/T1 series standards.
This standard is proposed by the Commission of Science, Technology and Industry for National Defense. This standard is under the jurisdiction of China Ordnance Industry Standardization Research Institute. The drafting units of this standard are: Huaibei Explosives Product Quality Supervision and Inspection Center of Coal Industry, Changsha Quality Supervision and Inspection Station of National Civilian Explosives Products, National Coal Mine Explosion-proof Safety Product Quality Supervision and Inspection Center, National Civilian Explosives Quality Supervision and Inspection Center, and China Ordnance Industry Standardization Research Institute. bzxz.net
Main drafters of this standard: Xia
Bin, Li Jianxiang, Song Jialiang, Zheng Fuliang, Wu Weiqin, Yang Jinxia, Dong Chunhai 1 Scope
National Standard of the People's Republic of China
Test method of safety of permissible electric-detonator in inflammable gas in coal mines Test method of safety of permissible electric-detonator in inflammable gas GB18096-2000
This standard specifies the materials, instruments, devices, test conditions, test steps and test result presentation for the test of the safety of permissible electric-detonator in inflammable gas in coal mines.
This standard is applicable to the test of the safety of permissible electric-detonator in inflammable gas in coal mines. 2 Definitions
This standard adopts the following definitions.
2.1 Permissible electric-detonator in coal mines Electric detonators allowed to be used underground in coal mines where there is a risk of explosion of inflammable gas or coal dust. 2.2 Inflammable gas; combustible gas is a gas that can burn or explode after mixing with air. 2.3 Safety safety
The safety level of electric detonators used in coal mines where there is a risk of explosion of combustible gas or coal dust. 3 Method summary
Place the tested electric detonator in a specific device filled with a combustible gas-air mixture and detonate it to observe whether it causes an explosion of the mixed gas. In a set of tests, the explosion frequency of the mixed gas is used to represent the combustible gas safety of the electric detonator. 4 Materials
Test gas: The volume fraction of methane should not be less than 90.0%, and the sum of the volume fractions of other combustible gases should not be greater than 1.0%. 5 Instruments and devices
5.1 Thermometer: The graduation value should not be greater than 1°C. 5.2 Methane detector: The graduation value should not be greater than 0.02%. 5.3 Hygrometer: The graduation value should not be greater than 5%. 5.4 Test device: As shown in Figure 1, the explosion box is a round barrel made of rolled steel plate with an inner diameter of 580mm ± 20mm and a length of 1200mm. One end is closed with a steel plate and the other end is open. The side wall is connected to a gas circulation mixing system, etc. Approved by the State Administration of Quality and Technical Supervision on May 9, 2000 and implemented on July 1, 2000
6 Test conditions
GB 18096-2000
1-Explosion box 2-Temperature detection port; 3-Methane detection port; 4-Detonator bracket; 5-Port end; 6-Explosion-proof fan 7-Valve Figure 1 Schematic diagram of the test device
The volume fraction of methane in the mixed gas in the explosion box should be 9.0%±0.3%, the temperature should be 5C~35℃, and the relative humidity should not be greater than 80%.
7 Test steps
7.1 Check and debug the test device
7.2 Place the electric detonator under test horizontally at the center of the detonator bracket in the explosion box, with the bottom of the electric detonator facing the loose end. 7.3 Use kraft paper or plastic film to seal the loose end of the explosion box. 7.4
Start the circulating mixing system.
7.5 Fill and discharge the test gas into the explosion box.
7.6 When the gas in the explosion box is evenly mixed and the methane content reaches the volume fraction specified in the test conditions, close the circulating mixing system. 7.7 Detonate the electric detonator under test and observe the detonation of the mixed gas after the electric detonator explodes. 7.8 Clear the gun smoke and restore the test device to the initial state. Expression of test results
The test results are expressed in detonation frequency, which is calculated as follows: A=B/C
Where: A-detonation frequency;
B-detonation number of each group of samples;
C——the total number of each group of samples.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This standard is formulated on the basis of MT62-1997 "Test Method and Judgment Rules for Safety of Underground Combustible Gases for Permissible Electric Detonators in Coal Mines" and in accordance with the requirements of GB/T1 series standards.
This standard is proposed by the Commission of Science, Technology and Industry for National Defense. This standard is under the jurisdiction of China Ordnance Industry Standardization Research Institute. The drafting units of this standard are: Huaibei Explosives Product Quality Supervision and Inspection Center of Coal Industry, Changsha Quality Supervision and Inspection Station of National Civilian Explosives Products, National Coal Mine Explosion-proof Safety Product Quality Supervision and Inspection Center, National Civilian Explosives Quality Supervision and Inspection Center, and China Ordnance Industry Standardization Research Institute. bzxz.net
Main drafters of this standard: Xia
Bin, Li Jianxiang, Song Jialiang, Zheng Fuliang, Wu Weiqin, Yang Jinxia, Dong Chunhai 1 Scope
National Standard of the People's Republic of China
Test method of safety of permissible electric-detonator in inflammable gas in coal mines Test method of safety of permissible electric-detonator in inflammable gas GB18096-2000
This standard specifies the materials, instruments, devices, test conditions, test steps and test result presentation for the test of the safety of permissible electric-detonator in inflammable gas in coal mines.
This standard is applicable to the test of the safety of permissible electric-detonator in inflammable gas in coal mines. 2 Definitions
This standard adopts the following definitions.
2.1 Permissible electric-detonator in coal mines Electric detonators allowed to be used underground in coal mines where there is a risk of explosion of inflammable gas or coal dust. 2.2 Inflammable gas; combustible gas is a gas that can burn or explode after mixing with air. 2.3 Safety safety
The safety level of electric detonators used in coal mines where there is a risk of explosion of combustible gas or coal dust. 3 Method summary
Place the tested electric detonator in a specific device filled with a combustible gas-air mixture and detonate it to observe whether it causes an explosion of the mixed gas. In a set of tests, the explosion frequency of the mixed gas is used to represent the combustible gas safety of the electric detonator. 4 Materials
Test gas: The volume fraction of methane should not be less than 90.0%, and the sum of the volume fractions of other combustible gases should not be greater than 1.0%. 5 Instruments and devices
5.1 Thermometer: The graduation value should not be greater than 1°C. 5.2 Methane detector: The graduation value should not be greater than 0.02%. 5.3 Hygrometer: The graduation value should not be greater than 5%. 5.4 Test device: As shown in Figure 1, the explosion box is a round barrel made of rolled steel plate with an inner diameter of 580mm ± 20mm and a length of 1200mm. One end is closed with a steel plate and the other end is open. The side wall is connected to a gas circulation mixing system, etc. Approved by the State Administration of Quality and Technical Supervision on May 9, 2000 and implemented on July 1, 2000
6 Test conditions
GB 18096-2000
1-Explosion box 2-Temperature detection port; 3-Methane detection port; 4-Detonator bracket; 5-Port end; 6-Explosion-proof fan 7-Valve Figure 1 Schematic diagram of the test device
The volume fraction of methane in the mixed gas in the explosion box should be 9.0%±0.3%, the temperature should be 5C~35℃, and the relative humidity should not be greater than 80%.
7 Test steps
7.1 Check and debug the test device
7.2 Place the electric detonator under test horizontally at the center of the detonator bracket in the explosion box, with the bottom of the electric detonator facing the loose end. 7.3 Use kraft paper or plastic film to seal the loose end of the explosion box. 7.4
Start the circulating mixing system.
7.5 Fill and discharge the test gas into the explosion box.
7.6 When the gas in the explosion box is evenly mixed and the methane content reaches the volume fraction specified in the test conditions, close the circulating mixing system. 7.7 Detonate the electric detonator under test and observe the detonation of the mixed gas after the electric detonator explodes. 7.8 Clear the gun smoke and restore the test device to the initial state. Expression of test results
The test results are expressed in detonation frequency, which is calculated as follows: A=B/C
Where: A-detonation frequency;
B-detonation number of each group of samples;
C——the total number of each group of samples.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG/T 2218.3-1991 Miehailing Aerosol Type C
- HG/T 21565-1995 Stirring drive device--installation of bottom cover
- GA 305-2001 General technical requirements for flame retardant PVC plastic flat conduits for electrical installations
- GB/T 8174-1987 Testing and evaluation of thermal insulation effect of equipment and pipelines
- HG/T 2837-1997 Water treatment agent sodium polymetaphosphate
- JB/T 7948.8-1999 Chemical analysis method for melting flux - Determination of phosphorus content by molybdenum blue photometry
- JB/T 10436-2004 Cross-linkable flame retardant polyolefin materials for wires and cables
- GB/T 5121.14-1996 Chemical analysis methods for copper and copper alloys - Determination of manganese content
- JB/T 3298-1996 Manual hydraulic pallet truck
- JB/T 5387-1991 Fatigue performance test method of roller chain and sleeve chain segments
- GB/T 14699.1-2005 Animal Feeding Stuffs---Sampling
- JB/T 6704-1993 Tractor clutch cover and pressure plate assembly technical conditions
- GB/T 15650-1995 Series and varieties of semiconductor integrated circuits Series and varieties of CMOS gate array circuits
- GB/T 15153.1-1998 Telecontrol equipment and systems Part 2: Working conditions Part 1: Power supply and electromagnetic compatibility
- GB/T 15635-1995 Electronic data interchange for administration,commerce and transport (EDIFACT)-Composite data elements directory
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com