HG/T 2436-1993 Pressure test method for glass tubes and fittings
time:
2024-08-13 06:58:03
- HG/T 2436-1993
- in force
Standard ID:
HG/T 2436-1993
Standard Name:
Pressure test method for glass tubes and fittings
Chinese Name:
玻璃管和管件耐压试验方法
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1993-06-14 -
Date of Implementation:
1994-01-01
Standard ICS number:
Chemical Technology>>Chemical Equipment>>71.120.99 Other Chemical EquipmentChina Standard Classification Number:
Chemical Industry>>Chemical Machinery and Equipment>>G94 Non-metallic Chemical Machinery and Equipment
Skip to download
Summary:
HG/T 2436-1993 Glass tube and fittings pressure test method HG/T2436-1993 standard download decompression password: www.bzxz.net
Some standard content:
Chemical Industry Standard of the People's Republic of China
HG/T2436-93
Pressure Test Method for Glass Tubes and Fittings
Published on June 14, 1993
Implementation on January 1, 1994
Published by the Ministry of Chemical Industry of the People's Republic of China Chemical Industry Standard of the People's Republic of China
Pressure Test Method for Glass Tubes and Fittings
Subject Content and Scope of Application
HG/T2436--93
This standard specifies the instruments, equipment, specimens, test procedures and result processing methods for the pressure test of glass tubes and fittings. This standard applies to the pressure resistance test of glass tubes and fittings. 2 Reference standards
QB961 Glass instrument internal stress test method Polarization optical measurement method HG/T2435 Glass tubes and pipe fittings
3 Equipment, instruments, test oxygen
3.1 Pump: electric or manual pressure pump with pressure ≥1MPa. 3.2 Pressure gauge: range 01MPa, accuracy not less than 1.0 level, dial diameter not less than 100mm, 3.3 Torque wrench: minimum division 0.5N·m, 3.4 Test device as shown in Figure 1,
3.5 Before the test, make a safety check on the pressure system. During the test, a 5mm thick organic glass cover should be used to separate the tester from the sample.
1-Water supply main 2-Pump or hand pump
3 Regulating valve 4-Pressure gauge 5-Pressure hose 6-Blue plate 7-Test sample Figure 1 Schematic diagram of test device
4 Test specimen
Approved by the Ministry of Chemical Industry of the People's Republic of China on June 14, 1993 and implemented on January 1, 1994
4.1 The test specimen shall meet all the requirements of HG/T2435
HG/T2436-93
"Glass Tubes and Fittings". In particular, the test specimens whose wall thickness and internal stress do not meet the standards shall not be used for internal pressure test. 4.2 After the test specimens have passed the size, appearance and stress tests, they shall be cleaned with tap water. 4.3 The number of samples in each group shall be in accordance with the provisions of Article 7.2.3 of HG/T2435 "Glass Tubes and Fittings". 5 Test steps
5.1 Install the qualified sample on the test device, use the torque wrench to evenly tighten the bolts, and the torque value of each bolt is shown in Table 1. 5.2 The sample should be installed horizontally and have appropriate support to reduce the existence of additional stress 5.3 Inject room temperature tap water into the sample until all the gas in the sample is discharged, and then close the water inlet valve and exhaust valve. 5.4 Test pressure: The test pressure of the glass tube is 2 times the design pressure; the test pressure of glass fittings and valves is 1.5 times the design pressure. See Table 1.
Glass tube, pipe torque on each bolt
Parts nominal diameter
DN(mm)
(Asbestos rubber gasket)
2.70—4.10
4.10—4.70
4.10-5.40
Torque on each bolt
(Hard polytetrafluoroethylene gasket)
2.70—4.10
4.10—4. 70
4.10—5.40
6.80--9.50
9.50—13.6Www.bzxZ.net
Glass tubes and fittingsGlass tubesTest pressure of glass fittingsGlass valvesGlass doorsDesign pressure
Test pressure
Test pressure
6.90-8.10
5.5Press to the test pressure at a speed not exceeding 20Kpa/s and maintain the pressure for not less than 5min. 6 Test results
6.1 Each sample is qualified if the test pressure does not drop and the glass tube does not break when there is no water leakage. 6.2 If one sample in each group of samples fails, the group of samples shall be judged as failed. 7 Test report
7.1 The test report shall contain the following contents:
7.1.1 Name of test item;
7.1.2 Source of samples;
7.1.3 Type, specification and description of samples:
7.1.4 Test pressure and pressure holding time;
Test conclusion (pass or fail):
Tester and date.
Design pressure
Test pressure
Additional instructions:
HG/T2436--93
This standard is proposed by China National Chemical Equipment Corporation. This standard is drafted by Beijing Glass Instrument Factory. The main drafters of this standard are Liu Jiajun and Zheng Limei. This standard adopts ASTM C601-77 "Standard Method for Determining Pressure of Glass Pipes". Format: People's Republic of China Chemical Industry Standard Glass Pipe and Fittings Pressure Test Method HG/T2436-93 China Chemical Equipment Corporation Postal Code 100011 Printing Beijing Institute of Chemical Technology Printing Factory Reproduction is prohibited Copyright reserved 880×1230 6100 First printing in August 1993 First edition in August 1993
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
HG/T2436-93
Pressure Test Method for Glass Tubes and Fittings
Published on June 14, 1993
Implementation on January 1, 1994
Published by the Ministry of Chemical Industry of the People's Republic of China Chemical Industry Standard of the People's Republic of China
Pressure Test Method for Glass Tubes and Fittings
Subject Content and Scope of Application
HG/T2436--93
This standard specifies the instruments, equipment, specimens, test procedures and result processing methods for the pressure test of glass tubes and fittings. This standard applies to the pressure resistance test of glass tubes and fittings. 2 Reference standards
QB961 Glass instrument internal stress test method Polarization optical measurement method HG/T2435 Glass tubes and pipe fittings
3 Equipment, instruments, test oxygen
3.1 Pump: electric or manual pressure pump with pressure ≥1MPa. 3.2 Pressure gauge: range 01MPa, accuracy not less than 1.0 level, dial diameter not less than 100mm, 3.3 Torque wrench: minimum division 0.5N·m, 3.4 Test device as shown in Figure 1,
3.5 Before the test, make a safety check on the pressure system. During the test, a 5mm thick organic glass cover should be used to separate the tester from the sample.
1-Water supply main 2-Pump or hand pump
3 Regulating valve 4-Pressure gauge 5-Pressure hose 6-Blue plate 7-Test sample Figure 1 Schematic diagram of test device
4 Test specimen
Approved by the Ministry of Chemical Industry of the People's Republic of China on June 14, 1993 and implemented on January 1, 1994
4.1 The test specimen shall meet all the requirements of HG/T2435
HG/T2436-93
"Glass Tubes and Fittings". In particular, the test specimens whose wall thickness and internal stress do not meet the standards shall not be used for internal pressure test. 4.2 After the test specimens have passed the size, appearance and stress tests, they shall be cleaned with tap water. 4.3 The number of samples in each group shall be in accordance with the provisions of Article 7.2.3 of HG/T2435 "Glass Tubes and Fittings". 5 Test steps
5.1 Install the qualified sample on the test device, use the torque wrench to evenly tighten the bolts, and the torque value of each bolt is shown in Table 1. 5.2 The sample should be installed horizontally and have appropriate support to reduce the existence of additional stress 5.3 Inject room temperature tap water into the sample until all the gas in the sample is discharged, and then close the water inlet valve and exhaust valve. 5.4 Test pressure: The test pressure of the glass tube is 2 times the design pressure; the test pressure of glass fittings and valves is 1.5 times the design pressure. See Table 1.
Glass tube, pipe torque on each bolt
Parts nominal diameter
DN(mm)
(Asbestos rubber gasket)
2.70—4.10
4.10—4.70
4.10-5.40
Torque on each bolt
(Hard polytetrafluoroethylene gasket)
2.70—4.10
4.10—4. 70
4.10—5.40
6.80--9.50
9.50—13.6Www.bzxZ.net
Glass tubes and fittingsGlass tubesTest pressure of glass fittingsGlass valvesGlass doorsDesign pressure
Test pressure
Test pressure
6.90-8.10
5.5Press to the test pressure at a speed not exceeding 20Kpa/s and maintain the pressure for not less than 5min. 6 Test results
6.1 Each sample is qualified if the test pressure does not drop and the glass tube does not break when there is no water leakage. 6.2 If one sample in each group of samples fails, the group of samples shall be judged as failed. 7 Test report
7.1 The test report shall contain the following contents:
7.1.1 Name of test item;
7.1.2 Source of samples;
7.1.3 Type, specification and description of samples:
7.1.4 Test pressure and pressure holding time;
Test conclusion (pass or fail):
Tester and date.
Design pressure
Test pressure
Additional instructions:
HG/T2436--93
This standard is proposed by China National Chemical Equipment Corporation. This standard is drafted by Beijing Glass Instrument Factory. The main drafters of this standard are Liu Jiajun and Zheng Limei. This standard adopts ASTM C601-77 "Standard Method for Determining Pressure of Glass Pipes". Format: People's Republic of China Chemical Industry Standard Glass Pipe and Fittings Pressure Test Method HG/T2436-93 China Chemical Equipment Corporation Postal Code 100011 Printing Beijing Institute of Chemical Technology Printing Factory Reproduction is prohibited Copyright reserved 880×1230 6100 First printing in August 1993 First edition in August 1993
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 3781.6-1993 Determination of apparent specific volume of acetylene black
- QB/T 2686-2005 Potato chips
- JB/T 3779-2002 Fast intermediate relay
- GB/T 5009.199-2003 Rapid detection of organophosphorus and carbamate pesticide residues in vegetables
- GB/T 5009.153-2003 Determination of phytic acid in plant-based foods
- GB/T 5287-2002 Extra large washers, grade C
- GB/T 3199-1996 Packaging, marking, transportation and storage of aluminum and aluminum alloy processed products
- QB/T 1594-1992 Circular saw sharpening machine
- GB/T 3795-1996 Ferromanganese
- CB 1085.1-1989 Instrument and meter manufacturing labor time quota Non-ferrous metal sand casting
- JB/T 6506-1992 Technical requirements for steam turbines for geothermal power generation
- JB/T 6382.3-1992 Cone seal welded conical pipe thread 90° elbow fitting
- GB 4706.33-2003 Safety of household and similar electrical appliances Particular requirements for commercial electric deep fat fryers
- QB/T 1742-1993 冷饮机
- HG/T 2724.2-1995 Test method for rubber threads - Determination of resistance to copper contamination during washing
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com