JB/T 4279.8-1994 Verification methods for enameled winding wire test equipment - Softening breakdown tester
time:
2024-06-12 11:38:15
- JB/T 4279.8-1994
- Abolished
Standard ID:
JB/T 4279.8-1994
Standard Name:
Verification methods for enameled winding wire test equipment - Softening breakdown tester
Chinese Name:
漆包绕组线试验仪器设备检定方法 软化击穿试验仪
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1994-12-09 -
Date of Implementation:
1995-06-01 -
Date of Expiration:
2008-07-01
China Standard Classification Number:
Electrical>>Electrical Production Equipment>>K91 Electrical Material Production Equipment
alternative situation:
Replaces JB 4279.8-1986; replaced by JB/T 4279.8-2008
Drafter:
Zhu BingDrafting Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryFocal point Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryProposing Organization:
Shanghai Cable Research Institute, Ministry of Machinery IndustryPublishing Department:
Ministry of Machinery Industry of the People's Republic of China

Skip to download
Summary:
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and treatment of enameled round wire softening and breakdown tester. This standard is applicable to the verification of enameled round wire softening and breakdown tester. JB/T 4279.8-1994 Verification method of enameled winding wire test equipment Softening and breakdown tester JB/T4279.8-1994 Standard download decompression password: www.bzxz.net

Some standard content:
Mechanical Industry Standard of the People's Republic of Chinabzxz.net
JB/T 4279.8 -1994
Verification method of enameled winding wire test instrument and equipment Softening breakdown tester
Published on December 9, 1994
Ministry of Machinery Industry of the People's Republic of China
Implementation on June 1, 1995
Mechanical Industry Standard of the People's Republic of China
Verification method of enameled winding wire test instrument and equipment Softening breakdown tester
1 Subject content and scope of application
JB/T4279.8-1994
Replaces JB4279.8-1986
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and processing of enameled round wire softening breakdown tester.
This standard applies to the calibration of enameled round wire softening breakdown tester. 2 Reference standards
JB/T4279.1 General principles for calibration methods of enameled winding wire test equipment Calibration items and technical requirements
3.1 The size of the heating mold of the enameled round wire softening breakdown tester is 100mm×100mm×70mm, and the allowable error is 1mm. The mold material is brass.
3.2 The two wire grooves of the tester heating mold should be vertical, and the intersection angle is 90°±5°. 3.3 The test voltage between the two specimens should be AC 100±10V. 3.4 When a current of 5±0.5mA passes through the two specimens, the tester should send a softening breakdown signal. 3.5 The short-circuit current between the specimens should not exceed 50mA. 3.6 The difference between the indicated temperature of the test instrument and the actual temperature of the intersection of the sample shall not exceed 2℃3.7 The allowable error of the test timing device for 120s is ±5s. 3.8
The load and the allowable error shall comply with the provisions of Table 1
Error±
Instruments for verification
Protractor.
4.2 Vernier caliper, 125mm, graduation value 0.02mm. 4.3 AC voltmeter, Class 1.5.
4.4 AC milliampere level, Class 1.5.
4.5 Thermocouple, nickel-copper-nickel (constantan), nickel-nickel-silicon or their materials, with a tested wire diameter of 0.5mm and a node diameter of not more than 2.0mm.
4.6 DC digital voltmeter, the allowable measurement error is ±0.05%. When using nickel-copper-nickel (constantan) thermocouples, the resolution of the digital voltmeter shall not be less than 10V; when using other thermocouples, the resolution of the digital voltmeter shall not be less than 1μV. 4.7 Stopwatch, graduation value 0.1s.
4.8 Frame balance and table scale, balance graduation value 1g; table scale graduation value 5g4.9 Variable resistor.
Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Verification method
5.1 General inspection
5.1.1 The tester is in a horizontal position.
JB/T4279.8-1994
5.1.2 Place the two specimens in the wire slot and lower the pressure rod. Check whether the intersection of the specimens is under the pressure rod. 5.2 Use a vernier caliper to measure the size of the heating mold. 5.3 Check the intersection angle of the two wire slots with a protractor. 5.4 Measure the test voltage with an AC voltmeter. 5.5 Connect the variable resistor and the AC milliammeter between the two test electrodes, gradually reduce the resistance of the resistor, and check the current indication value when the tester sends a breakdown signal.
5.6 Connect the AC milliammeter between the two test electrodes to check the short-circuit current. 5.7 Adjust the tester to the specified temperature. After entering the constant temperature state, place the thermocouple at the intersection of the two samples, lower the pressure rod, and check the difference between the temperature at the intersection of the two samples and the indicated temperature of the tester. 5.8 Use a stopwatch to measure the error of the timing device of the tester for 120s. 5.9 Use a balance and table to measure the load.
Processing of verification results
6.1 A verification certificate will be issued to the qualified enameled round wire softening breakdown tester, and a verification result notice will be issued to the unqualified one. The cover forms of the verification certificate and verification result notification are shown in the appendix of JB/T4279.1. 6.2 The initial verification of the enameled round wire softening breakdown tester is carried out according to all verification items, and the periodic verification only needs to verify the items specified in Articles 5.4, 5.5, 5.7 and 5.8 of this standard.
6.3 The verification cycle of the enameled round wire softening breakdown tester is generally set at 2 years. Additional notes:
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. The main drafter of this standard is Zhu Bing.
People's Republic of China
Mechanical Industry Standard
Enameled Winding Wire Test Instrument and Equipment Verification Method Softening Breakdown Tester
JB/T 4279.8 - 1994
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2 Shouti South Road, Beijing
Format 880×1230
Edition X, XX, 19XX
Printing 1-xXX
Postal Code 100044)
Sheet X/X
Number of Words XXX,XXX
Printing x, XX, 19XX
Price XXX.XX Yuan
XX-XXX
Mechanical Industry Standard Service Network: http://www.JB.ac.cn61- 86
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
JB/T 4279.8 -1994
Verification method of enameled winding wire test instrument and equipment Softening breakdown tester
Published on December 9, 1994
Ministry of Machinery Industry of the People's Republic of China
Implementation on June 1, 1995
Mechanical Industry Standard of the People's Republic of China
Verification method of enameled winding wire test instrument and equipment Softening breakdown tester
1 Subject content and scope of application
JB/T4279.8-1994
Replaces JB4279.8-1986
This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and processing of enameled round wire softening breakdown tester.
This standard applies to the calibration of enameled round wire softening breakdown tester. 2 Reference standards
JB/T4279.1 General principles for calibration methods of enameled winding wire test equipment Calibration items and technical requirements
3.1 The size of the heating mold of the enameled round wire softening breakdown tester is 100mm×100mm×70mm, and the allowable error is 1mm. The mold material is brass.
3.2 The two wire grooves of the tester heating mold should be vertical, and the intersection angle is 90°±5°. 3.3 The test voltage between the two specimens should be AC 100±10V. 3.4 When a current of 5±0.5mA passes through the two specimens, the tester should send a softening breakdown signal. 3.5 The short-circuit current between the specimens should not exceed 50mA. 3.6 The difference between the indicated temperature of the test instrument and the actual temperature of the intersection of the sample shall not exceed 2℃3.7 The allowable error of the test timing device for 120s is ±5s. 3.8
The load and the allowable error shall comply with the provisions of Table 1
Error±
Instruments for verification
Protractor.
4.2 Vernier caliper, 125mm, graduation value 0.02mm. 4.3 AC voltmeter, Class 1.5.
4.4 AC milliampere level, Class 1.5.
4.5 Thermocouple, nickel-copper-nickel (constantan), nickel-nickel-silicon or their materials, with a tested wire diameter of 0.5mm and a node diameter of not more than 2.0mm.
4.6 DC digital voltmeter, the allowable measurement error is ±0.05%. When using nickel-copper-nickel (constantan) thermocouples, the resolution of the digital voltmeter shall not be less than 10V; when using other thermocouples, the resolution of the digital voltmeter shall not be less than 1μV. 4.7 Stopwatch, graduation value 0.1s.
4.8 Frame balance and table scale, balance graduation value 1g; table scale graduation value 5g4.9 Variable resistor.
Approved by the Ministry of Machinery Industry on December 9, 1994
Implemented on June 1, 1995
Verification method
5.1 General inspection
5.1.1 The tester is in a horizontal position.
JB/T4279.8-1994
5.1.2 Place the two specimens in the wire slot and lower the pressure rod. Check whether the intersection of the specimens is under the pressure rod. 5.2 Use a vernier caliper to measure the size of the heating mold. 5.3 Check the intersection angle of the two wire slots with a protractor. 5.4 Measure the test voltage with an AC voltmeter. 5.5 Connect the variable resistor and the AC milliammeter between the two test electrodes, gradually reduce the resistance of the resistor, and check the current indication value when the tester sends a breakdown signal.
5.6 Connect the AC milliammeter between the two test electrodes to check the short-circuit current. 5.7 Adjust the tester to the specified temperature. After entering the constant temperature state, place the thermocouple at the intersection of the two samples, lower the pressure rod, and check the difference between the temperature at the intersection of the two samples and the indicated temperature of the tester. 5.8 Use a stopwatch to measure the error of the timing device of the tester for 120s. 5.9 Use a balance and table to measure the load.
Processing of verification results
6.1 A verification certificate will be issued to the qualified enameled round wire softening breakdown tester, and a verification result notice will be issued to the unqualified one. The cover forms of the verification certificate and verification result notification are shown in the appendix of JB/T4279.1. 6.2 The initial verification of the enameled round wire softening breakdown tester is carried out according to all verification items, and the periodic verification only needs to verify the items specified in Articles 5.4, 5.5, 5.7 and 5.8 of this standard.
6.3 The verification cycle of the enameled round wire softening breakdown tester is generally set at 2 years. Additional notes:
This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. The main drafter of this standard is Zhu Bing.
People's Republic of China
Mechanical Industry Standard
Enameled Winding Wire Test Instrument and Equipment Verification Method Softening Breakdown Tester
JB/T 4279.8 - 1994
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2 Shouti South Road, Beijing
Format 880×1230
Edition X, XX, 19XX
Printing 1-xXX
Postal Code 100044)
Sheet X/X
Number of Words XXX,XXX
Printing x, XX, 19XX
Price XXX.XX Yuan
XX-XXX
Mechanical Industry Standard Service Network: http://www.JB.ac.cn61- 86
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 2321-2004 Straight knife cutting machine
- QB/T 2723-2005 Leather chemical tests - Calculation of tannin penetration, leather quality and combined tannins
- GB/T 14699.1-2005 Animal Feeding Stuffs---Sampling
- GB/T 9239-1988 Determination of allowable unbalance for balancing quality of rigid rotors
- JB/T 7151-1993 Test method for loosening operation of crawler bulldozer
- GB/T 15696-1995 Information processing systems Open Systems Interconnection Connection-oriented Presentation Protocol Specification
- GBZ 34-2002 Diagnostic criteria for occupational acute pentachlorophenol poisoning
- HG/T 2874-1997 Determination of thermal shrinkage of microporous materials for footwear
- SJ 1.10-1987 Provision and requirements for preparation and revision of technical standards for electronic industry-Main contents of minutes made at meetings for reviewing draft standards
- LS/T 1705-2004 Classification and codes of grain information--Classification and codes of grain establishment
- MZ/T 136-2019 Technical specification for cosmetic operation of corpse
- GBJ 88-1985 Standard for the measurement of sound absorption coefficient and acoustic impedance using the standing wave tube method
- GBZ 43-2002 Diagnostic criteria for occupational acute pyrethroid poisoning
- CB/T 3480-1992 Steel through-tank pipe fittings
- JB/T 5507-1991 CGR-54 Permanent Magnetic Double Roller Intensive Magnetic Separator
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com