JB/T 5268.2-1991 Cable metal sheath part 2 lead sheath
time:
1991-06-28 16:00:00
- JB/T 5268.2-1991
- in force
Standard ID:
JB/T 5268.2-1991
Standard Name:
Cable metal sheath part 2 lead sheath
Chinese Name:
电缆金属套 第二部分 铅套
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1991-06-28 -
Date of Implementation:
1992-07-01
China Standard Classification Number:
Electrician>>Electrical Materials and General Parts>>K13 Cable and Accessories
Drafter:
Xu YinglinDrafting Organization:
Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic IndustryFocal point Organization:
Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic IndustryProposing Organization:
Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic IndustryPublishing Department:
Ministry of Machinery Industry of the People's Republic of China

Skip to download
Summary:
This standard specifies the models, technical requirements, test methods and inspection rules for lead sheaths for cables. This standard is applicable to lead sheaths for paper insulated power cables with an AC rated voltage of 35 kV and below and lead sheaths for communication cables with long-term working internal pressures not greater than (0.07 MPa) control cables or lead sheaths for signal cables. JB/ T 5268.2-1991 Cable metal sheath part 2 lead sheath JB/T5268.2-1991 Standard download and decompression password: www.bzxz.net

Some standard content:
Pressing Machinery Ring Industry Standard JB/T5268.21991
1991-06-284||tt ||e
1992-07-01
G2 0P pEe/
JB/ T5268.21991
This standard adopts IEC55-2 (1981) "Copper core or aluminum core paper insulated metal sheathed electric cable with rated voltage 18/30kV and below (excluding pressure cables and oil-filled cables) No. 2 Section: Overview and Structural Requirements". 1 Subject space and scope of application
1.1 Subject content
This standard specifies the model, technical requirements, test methods and inspection rules of lead sheaths for cables. 1.2 Scope of application
1.2.1 This standard is applicable to lead sheaths for paper insulated power cables with AC rated voltage 35kV and below and lead sheaths for communication cables with long-term working internal pressure not greater than 0.07MPa. Lead sheaths for control cables or signal cables can be used as a reference. 1.2.2 This standard does not apply to lead sleeves with other special requirements or structures. 1.2.3 This standard should be used together with JB5268.1. 2 Reference standards
GB2952.2 Cable outer sheath Part 2: Universal outer sheath for metal-sheathed cables GB4103
3 Models
Chemical analysis of lead-based alloys Method
Lead ingot
The model of the lead sleeve is Q.
4 Technical requirements
4.1 The lead sleeve should be made of lead alloy. Lead alloy should contain 0.4% to 0.8% antimony and 0.02% to 0.06% copper, with the balance being lead (referred to as lead-antimony-copper alloy or Pb--Sb--Cu alloy), or 0.2% to 0.4% tin , 0.4% ~ 0.6% antimony and 0.02% 0.06% copper, the balance is lead (referred to as lead-tin-antimony-copper alloy or Pb-Sn-Sb-Cu alloy). Other lead alloys with properties equal to or better than those of the above-mentioned lead alloys can also be used. In lead alloys, except for the active ingredients, the content of other impurities should not exceed the requirements for Pb-No. 2 lead ingots in GB469. 4.2 Thickness of the lead sheath
4.2.1 The nominal thickness of the lead sheath is related to the assumed diameter before the lead sheath and the cable type. It should be calculated and determined using formula (1), but the minimum nominal thickness should comply with the provisions of Table 1 .
Where: A--the nominal thickness of the lead sleeve, mm, the calculated value should be rounded to one decimal place ;D The fixed diameter of the lead sleeve, that is, the fixed diameter of the cable core, mm, is calculated according to the provisions of Appendix A of GB2952.2. The calculated value should be rounded to one decimal place
a and b coefficients, which should comply with the table 1 regulations.
1991-06-28
1992-07-01
category
different
electricity
electricity
Electricity
Letter
Outer sheath type
Thick steel wire or no outer sheath||tt ||Split-phase lead sheath with outer sheath
Other outer sheaths
Thick steel wire armor
No outer sheath
Other outer sheaths||tt| |JB/T5268.21991
Ph-Sb--Cu
0.03||tt ||0.02
For control cables and signal cables, please refer to the nominal thickness of the lead sheath used for power cables. Note,
The average thickness of the lead sleeve should not be less than the specified nominal thickness. 4.2.2bzxZ.net
Pb-Sn-Sb-Cu
Minimum nominal thickness
1.2||tt| |1.2
The minimum thickness of the lead sleeve should not be less than 95% of the specified nominal thickness minus 0.1mm, and the calculated value should be rounded to two decimal places. 4.2.3
The maximum thickness of the lead sleeve is not specified.
The thickness of the lead sleeve at the joint when the intermittent lead pressing machine is stopped will not be assessed. 4.2.5
4.3 The lead sleeve should be sealed
4.4 There should be no inclusions such as lead slag on the lead sleeve, and no scratches or dents exceeding the minimum thickness requirements are allowed. 4.5 When the inner diameter of the lead sleeve is greater than 15mm, an expansion test should be carried out. When the inner diameter of the lead sleeve is expanded to 1.3 times its original inner diameter, the lead sleeve should not break.
5 Test methods
Lead alloy composition content inspection (Article 4.1) should be carried out in accordance with GB4103 regulations. 5.1
5.2 The inspection of the thickness of the lead sheath (Article 4.2) shall be carried out according to the method specified in Article 5.3 of JB5268.1. 5.3 For the communication cable lead sheath sealing test (Article 4.3), use dry air or inert gas filled with a pressure of 0.3~0.5MPa. Inflation should be carried out until the above air pressure is stable over the entire length of the cable. After the air pressure stabilizes, for lead sheaths without outer sheaths, the air pressure should not drop within 3 hours, and for lead sheaths with outer sheaths, the air pressure should not drop within 6 hours. For power cables, the tightness of the lead sheath is visually inspected. 5.4 Surface quality inspection (Article 4.4) should be carried out according to the method specified in JB5268.1 Article 5.2. If necessary, the thickness of the scratched or depressed area can be measured according to the method in Article 5.2.
5.5 Lead sheath expansion test (Article 4.5), a 150mm long lead pipe without mechanical damage should be taken and placed on a cone with a bottom diameter and height ratio of 1:3. Under lubrication, The lead pipe is expanded to the required inner diameter. 6 Inspection Rules
Lead sheaths should be inspected in accordance with Table 2.
Serial number
Inspection items| |tt||Lead alloy composition
Thickness of lead sheath
Tightness
Surface quality
Expansion test
Provision number
No. 41 Article
Article 4.2
Article 4.3
Article 4.4
Article 4.5
Inspection Type||tt| |T,s
Sampling inspection cycle| |tt||3d once
10% of the number of delivered roots
at least one
id once
24h times
Test method|| tt||GB4103
JB5268.1 Article 5.3
Article 5.3
Article 5.4
Article 5.5
2| |tt||3
Additional notes:
JB/T5268.21991
This standard is proposed and managed by the Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic Industry and others. The main drafter of this standard is Xu Yinglin.
This standard communication cable lead sheath is partially based on the Soviet national standard FOCT9358-75 "Communication Cable Lead Sheath". E
5268.21991
880A1230
19XXAXX
100044
XXX,XXX
xX should|| tt||X?
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
1991-06-284||tt ||e
1992-07-01
G2 0P pEe/
JB/ T5268.21991
This standard adopts IEC55-2 (1981) "Copper core or aluminum core paper insulated metal sheathed electric cable with rated voltage 18/30kV and below (excluding pressure cables and oil-filled cables) No. 2 Section: Overview and Structural Requirements". 1 Subject space and scope of application
1.1 Subject content
This standard specifies the model, technical requirements, test methods and inspection rules of lead sheaths for cables. 1.2 Scope of application
1.2.1 This standard is applicable to lead sheaths for paper insulated power cables with AC rated voltage 35kV and below and lead sheaths for communication cables with long-term working internal pressure not greater than 0.07MPa. Lead sheaths for control cables or signal cables can be used as a reference. 1.2.2 This standard does not apply to lead sleeves with other special requirements or structures. 1.2.3 This standard should be used together with JB5268.1. 2 Reference standards
GB2952.2 Cable outer sheath Part 2: Universal outer sheath for metal-sheathed cables GB4103
3 Models
Chemical analysis of lead-based alloys Method
Lead ingot
The model of the lead sleeve is Q.
4 Technical requirements
4.1 The lead sleeve should be made of lead alloy. Lead alloy should contain 0.4% to 0.8% antimony and 0.02% to 0.06% copper, with the balance being lead (referred to as lead-antimony-copper alloy or Pb--Sb--Cu alloy), or 0.2% to 0.4% tin , 0.4% ~ 0.6% antimony and 0.02% 0.06% copper, the balance is lead (referred to as lead-tin-antimony-copper alloy or Pb-Sn-Sb-Cu alloy). Other lead alloys with properties equal to or better than those of the above-mentioned lead alloys can also be used. In lead alloys, except for the active ingredients, the content of other impurities should not exceed the requirements for Pb-No. 2 lead ingots in GB469. 4.2 Thickness of the lead sheath
4.2.1 The nominal thickness of the lead sheath is related to the assumed diameter before the lead sheath and the cable type. It should be calculated and determined using formula (1), but the minimum nominal thickness should comply with the provisions of Table 1 .
Where: A--the nominal thickness of the lead sleeve, mm, the calculated value should be rounded to one decimal place ;D The fixed diameter of the lead sleeve, that is, the fixed diameter of the cable core, mm, is calculated according to the provisions of Appendix A of GB2952.2. The calculated value should be rounded to one decimal place
a and b coefficients, which should comply with the table 1 regulations.
1991-06-28
1992-07-01
category
different
electricity
electricity
Electricity
Letter
Outer sheath type
Thick steel wire or no outer sheath||tt ||Split-phase lead sheath with outer sheath
Other outer sheaths
Thick steel wire armor
No outer sheath
Other outer sheaths||tt| |JB/T5268.21991
Ph-Sb--Cu
0.03||tt ||0.02
For control cables and signal cables, please refer to the nominal thickness of the lead sheath used for power cables. Note,
The average thickness of the lead sleeve should not be less than the specified nominal thickness. 4.2.2bzxZ.net
Pb-Sn-Sb-Cu
Minimum nominal thickness
1.2||tt| |1.2
The minimum thickness of the lead sleeve should not be less than 95% of the specified nominal thickness minus 0.1mm, and the calculated value should be rounded to two decimal places. 4.2.3
The maximum thickness of the lead sleeve is not specified.
The thickness of the lead sleeve at the joint when the intermittent lead pressing machine is stopped will not be assessed. 4.2.5
4.3 The lead sleeve should be sealed
4.4 There should be no inclusions such as lead slag on the lead sleeve, and no scratches or dents exceeding the minimum thickness requirements are allowed. 4.5 When the inner diameter of the lead sleeve is greater than 15mm, an expansion test should be carried out. When the inner diameter of the lead sleeve is expanded to 1.3 times its original inner diameter, the lead sleeve should not break.
5 Test methods
Lead alloy composition content inspection (Article 4.1) should be carried out in accordance with GB4103 regulations. 5.1
5.2 The inspection of the thickness of the lead sheath (Article 4.2) shall be carried out according to the method specified in Article 5.3 of JB5268.1. 5.3 For the communication cable lead sheath sealing test (Article 4.3), use dry air or inert gas filled with a pressure of 0.3~0.5MPa. Inflation should be carried out until the above air pressure is stable over the entire length of the cable. After the air pressure stabilizes, for lead sheaths without outer sheaths, the air pressure should not drop within 3 hours, and for lead sheaths with outer sheaths, the air pressure should not drop within 6 hours. For power cables, the tightness of the lead sheath is visually inspected. 5.4 Surface quality inspection (Article 4.4) should be carried out according to the method specified in JB5268.1 Article 5.2. If necessary, the thickness of the scratched or depressed area can be measured according to the method in Article 5.2.
5.5 Lead sheath expansion test (Article 4.5), a 150mm long lead pipe without mechanical damage should be taken and placed on a cone with a bottom diameter and height ratio of 1:3. Under lubrication, The lead pipe is expanded to the required inner diameter. 6 Inspection Rules
Lead sheaths should be inspected in accordance with Table 2.
Serial number
Inspection items| |tt||Lead alloy composition
Thickness of lead sheath
Tightness
Surface quality
Expansion test
Provision number
No. 41 Article
Article 4.2
Article 4.3
Article 4.4
Article 4.5
Inspection Type||tt| |T,s
Sampling inspection cycle| |tt||3d once
10% of the number of delivered roots
at least one
id once
24h times
Test method|| tt||GB4103
JB5268.1 Article 5.3
Article 5.3
Article 5.4
Article 5.5
2| |tt||3
Additional notes:
JB/T5268.21991
This standard is proposed and managed by the Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Mechanical and Electronic Industry and others. The main drafter of this standard is Xu Yinglin.
This standard communication cable lead sheath is partially based on the Soviet national standard FOCT9358-75 "Communication Cable Lead Sheath". E
5268.21991
880A1230
19XXAXX
100044
XXX,XXX
xX should|| tt||X?
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- SY 4032.4-1993 Petroleum Construction Project Quality Inspection and Assessment Standard Communication Engineering (Long-distance Communication Open Line Carrier Telephone Installation Engineering)
- GB/T 15370-2004 General technical requirements for agricultural wheeled and crawler tractors
- QB/T 2745-2005 Cooking rice wine
- GB 8296-1987 Determination of manganese content in natural rubber latex (potassium periodate photometric method)
- GB/T 4960.5-1996 Terminology of nuclear science and technology Radiation protection and safety of radiation sources
- GB 12282.2-1990 Life test tables Simple linear unbiased estimation tables (extreme value distribution, Weibull distribution)
- QB/T 3691-1999 Box-type barley germination system
- JB/T 7733-1995 Technical requirements for small harvester
- JB/T 10358-2002 Water-cooled cables for industrial electric heating equipment
- JB/T 6324-1992 KE type 50A to 500A thyristors for electric welding machines
- GB/T 5329-1985 Test sieves and test sieving--Vocabulary
- HG/T 2968-1999 Industrial Sodium Pyrophosphate
- HG 2957.5-1984 Determination of aluminum content of alum ore Volumetric method
- HG/T 2347.1-1992 γ.Fe2O3 magnetic powder
- JB/T 9206-1999 Hot-dip aluminum processing and quality inspection for steel
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]